Mettler Toledo, 30571940, Analyzer 2850Si Silica 1/Pnl/PO4

CATALOG NUMBER: 30571940
السعر العادي$0.99
/
  • In stock, ready to ship

  • الطلب مؤجل، سيتم الشحن قريباً

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description
Specification Silica measurement range: 0-5000 ppb, limit of detection per ASTM Method D7126 Phosphate measurement range: 0.3 - 10 ppm Operating Range (Temp.): 5 °C – 60 °C 41 °F – 140 °F Sample Flow rate: 50 – 250 mL / min Process Connection: Sample inlet: 6 mm or 1/4" OD tube SS compression fitting Drain hose: 19 x 25.4 mm (¾ x 1"), 2 m (6 ft) length included Ingress Protection: IP66 / NEMA4X (Electronics) Silica Measurement Accuracy: ± 5 % of reading or ± 1 ppb, whichever is greater Operator Interface: Simultaneous display of silica and/or phosphate concentration and measurement or auto-cal status TFT color touchscreen Zero calibration: Automatic, every measurement cycle Analog Output: Powered 0 / 4 – 20 mA, 22 mA alarm, 500 ohm max load, not for use with externally powered circuit Analog Output Scaling: Linear, bi-linear, logarithmic (1,2,3,4 decades), auto ranging Power Supply: 100 – 240 VAC, 50 – 60 Hz, 100 W on power loss all settings are retained without batteries Power Supply (AC/DC): 100 V – 240 V Flow Rate: 50 mL/min – 250 mL/min Digital Input: Remote start / stop of measurement cycle Measurement Parameter: Silica/Phosphate Reagent Consumption: Approx 500 mL each per 3 months with 20 min measurement cycle time Humidity: 10 – 90 % non-condensing Communication: PROFIBUS DP Grab Sample Measurement: 500 mL capacity Phosphate Measurement Accuracy: ± 10 % of reading or ± 0.3 ppm, whichever is greater Sample Pressure: 0.3 – 7 bar (5 – 100 psig) Analog Output Accuracy: ± 0.05 mA Measurement Cycle Time: 20 min typical Adjustable ≥ 10 min Weight: 16 kg (35 lbs) Sample Temperature: 5 – 60 °C (41 – 140 °F) Model Family: 2850Si EnclosureType: Panel Dimensions HWD: Panel: 533 x 368 x 270 mm (21.0" x 14.5" x 10.6") Outputs: 8 Powered 0 / 4 – 20 mA Relay Contact(s): 4-SPST Type Reed 250 VAC or DC, 0.5 A 4-SPST mechanical rated at 250 VAC, 3 A Resolution: 4 digits with decimal, autoranging 0.001 ppb in lowest range Built-in sequencer: No Ambient Operating Temperature: 10 – 50 °C (50 – 122 °F) Ratings/Approvals: CE, cЯUus Span calibration: Automatic per schedule once per month, typical

Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924