Mettler Toledo, 58045001, Bioburden Analyzer 7000RMS Online

CATALOG NUMBER: 58045001
السعر العادي$0.99
/
  • In stock, ready to ship

  • الطلب مؤجل، سيتم الشحن قريباً

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description
Specification Operating Range (Temp.): 0 °C – 37 °C Operating Range (Humidity): 10 % – 90 % Flow Rate: 30 mL/min – 100 mL/min Dimensions (HxWxD): 616 mm x 564 mm x 305 mm Analysis Time: Continuous Wall Mount: Anti-vibration shelf required (P/N 58 079 700) Minimum detection size: ≥ 0.3 μm Inlet pressure: 21 - 80 psig (2 - 5.5 bar(g)) Calibration, cleaning and grab sample requires sample pressure of 0 psig (0 bar(g) Process pressure above 80 psig (5.5 bar(g)) requires optional High Pressure Regulator (P/N 58 091 552) Humidity (non-condensing): 80% maximum relative humidity up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F) Ambient temperature (non-condensing): 1 - 37 °C (32 - 98.6 °F) Temperature below 15 °C or above 45 °C requires Sample Conditioning Coil (included) Voltage: MAINS supply voltage fluctuations up to ±10% of the nominal voltage of 100 - 240 VAC 50 - 60 Hz TEMPORARY OVERVOLTAGES occurring on the MAINS SUPPLY TRANSIENT OVERVOLTAGES: up to levels of OVERVOLTAGE CATEGORY II Data communication: 5 - 20 mA standard, with configurable output ranges Analog output channels Ethernet - standard RJ 45 / Wi-Fi capable SCADA connectivity via Modbus TCP USB Enclosure Material: Stainless Steel Measurement Range: 1 -10,000 AFU / mL Response Time: 3 seconds (1 mL) Physical dimensions: (WxHxD) 22.2"(56.4 cm) W x 24.25"(61.6 cm) H x 12"(30.5 cm) D Monitoring location: At-line to drain Flow rate: 31 mL/min Use: Indoor use Environmental Temperature: 6 - 35 °C (41- 95 °F) Weight: 73.4 lbs (33.3 kg) Outlet connection: 0.125" (3 mm) O.D. Inlet connection: 0.125" (3 mm) O.D. Power Requirements: 100 - 240 VAC 50 - 60 Hz 5A Use the power cord included with the instrument 8.2' (2.5 m) cord length provided standard Temperature (non-condensing): 6 - 90 °C (41-194 °F) Temperature below 15 °C or above 45 °C requires Sample Conditioning Coil (included) Environment: Pollution degree 3 Detection limit: 2 AFU (Auto Fluorescent Units) Type / Quality: Purified Water (PW), Ultrapure Water (UPW), Water for Injection (WFI) Altitude: Up to 6562' (2000 m)

Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924