Iright
BRAND / VENDOR: Mettler Toledo

Mettler Toledo, 58042003, Analyzer 2301Na Panel Assy

CATALOG NUMBER: 58042003
Precio habitual$0.99
/
Los gastos de envío se calculan en la pantalla de pagos.
  • In stock, ready to ship

  • Pedido pendiente, envío pronto

Este sitio está protegido por hCaptcha y se aplican la Política de privacidad de hCaptcha y los Términos del servicio.

Product Description
Specification Sodium Measurement Range: 0.01-100,000 ppb or equivalent ppm, auto-ranging Sodium Measurement Accuracy: ± 10% of reading ± 0.1 ppb, typical using DIPA as reagent ± 10% of reading ± 1 ppb, typical using ammonium hydroxide as reagent Response Time: 90% at 5 minutes Sample pH: 2.5-12 Update Rate: Once per second Reagent Consumption: 3-4 L per year DIPA, or 9-12 L per year ammonium hydroxide typical more at higher temperatures and for cation exchange samples Sample Flow rate: >40 mL/min (>20 mL/min for cation exchange samples), excess to drain Sample Temperature: 5-50°C (41-122°F) Sample Pressure: 0.3-7 bar (5-100 psig) Grab Sample Measurement: Available option Power Supply: 100-240 VAC, 50-60 Hz, 25 W, on power loss all settings are retained without batteries Dimensions (HxWxD): 851 mm x 400 mm x 165 mm Weight: 4.5 kg (10 lbs) Ambient Operating Temperature: 5-50 °C (41-122 °F) Humidity: 10-90% non-condensing Ratings/Approvals: CE, UL, IP65 Process Connection: Sample inlet: 6 mm or 1/4" OD tube SS compression fitting Drain hose: 19 x 25.4 mm (¾ x 1"), 2 m (6 ft) length included Analog Output: 22mA alarm, 500 ohm max load, not for use with externally powered circuit For sodium, conditioned pH, temperature four powered 0/4-20 mA, Power Supply (AC/DC): 100 V – 240 V Analog Output Scaling: Linear, bi-linear, logarithmic (1,2,3,4 decades), auto ranging Flow Rate: 40 mL/min – 60 mL/min Measurement Parameter: Sodium Electrode Conditioning: Manual Operating Range (Temp.): 5 °C – 50 °C Relay Contacts: 3 A resistive freely assignable to set-points for sodium, pH, temperature Sodium Calibration: Manual 3-point known addition manual 1- or 2-point Operating Range: 0.01 ppb – 100,000 ppb Analog Output Accuracy: ±0.05 mA EnclosureType: Panel Outputs: 4 Analog Built-in sequencer: No

Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924