Product Description

The QIAstat-Dx Rise Base is a benchtop in vitro diagnostic device for use with QIAstat-Dx assays and QIAstat-Dx Analytical Modules. It provides full automation from sample preparation to real-time PCR detection. This higher-throughput system can accommodate up to 160 patient samples per day using 8 Analytical Modules.
Show more

Features

- Uses real-time PCR to deliver comprehensive results for up to 160 patient samples per day with 8 Analytical Modules
- Easily view Ct values and amplification curves for all detected pathogens
- Single-step cartridge preparation with no precision pipetting required
- Easily load the full capacity of cartridges in just a few minutes, or add them continuously, whenever needed
- Safely dispose of all used cartridges from the waste tray in one quick step

Product Details

- Scalable, high-throughput testing

- Smart drawer system for efficient processing

- Versatility that matches your workflow

QIAstat-Dx simplifies infectious disease diagnostics so you can get faster results for your patients. All you need is a patient sample, a QIAstat-Dx assay cartridge and one of our intuitive QIAstat-Dx instruments.

QIAstat-Dx Rise is our higher-throughput powerhouse, built to fit the needs of high-demand institutions. Combined with QIAstat-Dx assay cartridges, QIAstat-Dx Rise uses multiplex PCR technology – also known as syndromic testing – to quickly survey many different pathogens in a single patient sample.

The cartridges come ready with all reagents preloaded and use our trusted assay chemistry. The system includes random access and batch testing options, with a daily capacity of 160 samples using 8 Analytical Modules. The QIAstat-Dx Rise also includes a multi-test front drawer that can process up to 16 cartridges at the same time, and 2 additional slots for urgent testing. When the test is done, all used cartridges are automatically disposed in the dedicated waste drawer.

Each instrument is made up of two components: 1) A QIAstat-Dx Rise Base, which contains the intuitive touch-screen interface and robotic system that moves and scans the cartridges within the device and 2) up to 8 Analytical Modules, letting you test up to eight samples at once.

With QIAstat-Dx Rise in your lab, you can get:

With scalability up to 8 Analytical Modules, QIAstat-Dx Rise adapts to your needs – automating up to 160 tests daily.

Load up to 16 cartridges at once – start new tests anytime and prioritize urgent samples without disruption.

Choose between targeted or syndromic panels – all on a single platform designed for diagnostic flexibility.

Plus, every QIAstat-Dx Analytical Module is compatible with both QIAstat-Dx Analyzer 2.0 and QIAstat-Dx Rise. Easily update your QIAstat-Dx testing format based on your evolving testing needs. Click here to know more about QIAstat-Dx Analyzer 2.0, our modular system perfect for labs of every size.

Principle

QIAstat-Dx Rise, combined with QIAstat-Dx assay cartridges, uses real-time PCR to detect pathogen nucleic acids in human biological samples. The instrument and cartridges are designed as a closed system that contains on board all necessary reagents, enabling hands-off sample preparation. Detected real-time amplification signals are interpreted by the integrated software and are reported via an intuitive user interface.

Procedure

Preparing a QIAstat-Dx cartridge using liquid transfer is efficient and fast. And once the cartridges are ready, it takes just a few minutes to load the full capacity of cartridges and start a run on QIAstat-Dx Rise.

Loading a sample into the QIAstat-Dx cartridge requires less than one minute of hands-on time with no precision pipetting.

Using the provided transfer pipette, the user applies a liquid sample to the main port of the QIAstat-Dx cartridge (see Applying a liquid sample to the QIAstat-Dx cartridge ).

Following the instructions on the QIAstat-Dx Rise touchscreen display, the user loads the prepared cartridges into the instrument’s loading tray (see Adding cartridges to the QIAstat-Dx Rise input tra y).

The QIAstat-Dx Rise will automatically scan the sample ID and cartridge barcodes, or the user can manually scan the barcodes. Once the user starts the run, the QIAstat-Dx Rise will autonomously process the samples.

The input tray also offers random and continuous access, meaning up to 2 additional tests can be added to an ongoing run at a moment’s notice.

Once the run is finished, the used cartridges are automatically placed in the dedicated waste tray so they can be disposed of safely and quickly.

Applications

Viruses: Bacteria
Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV-2): Parainfluenza virus 1
Influenza A: Parainfluenza virus 2
Influenza A H1N1 pdm09: Parainfluenza virus 3
Influenza A H1: Parainfluenza virus 4
Influenza A H3: Adenovirus
Influenza B: Respiratory syncytial virus
Human Coronavirus 229E: Human metapneumovirus
Human Coronavirus HKU1: Human Rhinovirus/Enterovirus (not differentiated)
Human Coronavirus NL63
Human Coronavirus OC43

Viruses
Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV-2) Influenza A Influenza B Respiratory syncytial virus Human Rhinovirus

Features: Specifications
Configuration: Modular syndromic testing system with QIAstat-Dx Rise Base, up to 8 QIAstat-Dx Analytical Modules and 1 QIAstat-Dx Rise Mobile Table (optional).
Instrument dimensions (WxHxD): QIAstat-Dx Rise Base (door closed): 22.8 x 50.4 x 31.9 in QIAstat-Dx Rise Base (door open): 59 x 50.4 x 31.9 in QIAstat-Dx Analytical Module: 6.0 x 12.1 x 16.9 in QIAstat-Dx Rise mobile table: 59.1 in x 41.3 in x 29.9-31.5 in For installation and service interventions, 59 in of space around the instrument is required.
Weight: QIAstat-Dx Rise Base: 286.6 lb QIAstat-Dx Analytical Module: 35.3 lb QIAstat-Dx Rise Mobile Table (load-bearing capacity): 573.2 lb
Power requirements: 200–240 VAC
Operating conditions: Specifications
Air temperature: 68–82.4 ̊F
Relative humidity: 20–80%
Altitude: 0–7217.8 m
Place of operation: Laboratory (inside)

QIAstat-Dx Respiratory Panel Plus: Our FDA-cleared test to analyze 21 viral and bacterial targets for common pathogens causing respiratory symptoms, including SARS-CoV-2.

This version of our assay replaces the QIAstat-Dx Respiratory SARS-CoV-2 Panel.

QIAstat-Dx Respiratory Panel Mini: Our FDA-cleared test to analyze 5 viral targets for common pathogens causing respiratory symptoms, including human rhinovirus. This targeted panel is ideal for low-risk patients.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924