A21+K wear metal standard, Ag, Al, B, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Si, Sn, Ti, V, Zn 50 µg/g, 100 g
Specifications:
Analyte Count: 22
Concentration: Aluminum50 µg/gCAS #: 7429-90-5Barium50 µg/gCAS #: 7440-39-3Boron50 µg/gCAS #: 7440-42-8Cadmium50 µg/gCAS #: 7440-43-9Calcium50 µg/gCAS #: 7440-70-2Chromium50 µg/gCAS #: 7440-47-3Copper50 µg/gCAS #: 7440-50-8Iron50 µg/gCAS #: 7439-89-6Lead50 µg/gCAS #: 7439-92-1Magnesium50 µg/gCAS #: 7439-95-4Manganese50 µg/gCAS #: 7439-96-5Molybdenum50 µg/gCAS #: 7439-98-7Nickel50 µg/gCAS #: 7440-02-0Phosphorus50 µg/gCAS #: 7723-14-0Potasium50 µg/gCAS #: 7440-09-7Silicon (as SiO2)50 µg/gCAS #: 7440-21-3Silver50 µg/gCAS #: 7440-22-4Sodium50 µg/gCAS #: 7440-23-5Tin50 µg/gTitanium50 µg/gCAS #: 7440-32-6Vanadium50 µg/gCAS #: 7440-62-2Zinc50 µg/gCAS #: 7440-66-6
Part Number Application: Organometallics
Part Number Application Domain: Petrochemical
Solvent: 75 cSt hydrocarbon oil
UNSPSC Code: 41116107
Volume: 100 g
**********The following product description is generated by AI and is for reference only. If you have any questions, please contact customer service.**********
This high-purity wear metal standard is formulated with Ag, Al, B, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Si, Sn, Ti, V, and Zn at 50 micrograms per gram in a 100-gram solution, making it ideal for precise multi-element calibration in elemental analysis. Designed for laboratories utilizing inductively coupled plasma optical emission spectrometry ICPOES and inductively coupled plasma mass spectrometry ICPMS, this standard supports accurate detection and quantification of key wear metals in lubricants, fuels, or other petrochemical samples. Common applications include condition monitoring, failure analysis, and research in tribology and industrial quality control. This certified reference material ensures reliability and traceability for routine testing or advanced research, and is manufactured to meet stringent quality criteria. It is optimally suited for use with Agilent spectroscopy platforms and compatible with comparable analytical instrumentation requiring trace metal standards. For laboratories requiring additional calibration ranges, complementary standards and single-element solutions are available. The solution is prepared with ultra-pure reagents to minimize matrix interference, ensuring consistent and reproducible analytical performance across varied applications. This product provides confidence in calibration accuracy and supports rigorous regulatory or internal quality requirements.