PerkinElmer initial calibration verification for ICP, AA, or GFAA, contains (μg/mL) 500 Ca, K, Mg, Na, 200 Al, in 5% HNO3, Ba, 100 Fe, 60 Sb, 50 Co, V, 40 Ni, 25 Cu, 20 Zn, 15 Mn, 10 Ag, As, Cr, Tl, in 5% HNO3, 5 Be, Cd, Se, 3 Pb
Specifications:
Analyte Count: 22
Concentration: Aluminum nitrate nonahydrate (ICP grade) (as aluminum)200 mg/LCAS #: 7784-27-2Antimony (ICP grade)60 mg/LCAS #: 7440-36-0Arsenic10 mg/LCAS #: 7440-38-2Barium nitrate (ICP grade) (as barium)200 mg/LCAS #: 10022-31-8Beryllium acetate basic5 mg/LCAS #: 19049-40-2Cadmium5 mg/LCAS #: 7440-43-9Calcium carbonate (ICP grade) (as calcium)500 mg/LCAS #: 471-34-1Chromium(III) nitrate10 mg/LCAS #: 13548-38-4Cobalt50 mg/LCAS #: 7440-48-4Copper25 mg/LCAS #: 7440-50-8Iron (III) nitrate (as iron)100 mg/LCAS #: 7782-61-8Lead3 mg/LCAS #: 7439-92-1Magnesium500 mg/LCAS #: 7439-95-4Manganese15 mg/LCAS #: 7439-96-5Nickel40 mg/LCAS #: 7440-02-0Potassium nitrate (as N)500 mg/LCAS #: 7757-79-1Selenium5 mg/LCAS #: 7782-49-2Silver10 mg/LCAS #: 7440-22-4Sodium carbonate (as carbonate)500 mg/LCAS #: 497-19-8Thallium10 mg/LCAS #: 7440-28-0Vanadium oxide50 mg/LCAS #: 1314-62-1Zinc20 mg/LCAS #: 7440-66-6
Solvent: 5% Nitric acid with 1% tartaric acid
UNSPSC Code: 41116107
Volume: 500 mL
**********The following product description is generated by AI and is for reference only. If you have any questions, please contact customer service.**********
This high-purity calibration verification solution is specifically formulated for initial calibration checks in elemental analysis applications using ICP, AA, or GFAA techniques. Each 100 mL unit contains a precisely balanced mixture of essential elements, including 500 μg/mL of calcium, potassium, magnesium, and sodium; 200 μg/mL aluminum and barium; 100 μg/mL iron; with additional trace metals such as antimony, cobalt, vanadium, nickel, copper, zinc, manganese, silver, arsenic, chromium, thallium, beryllium, cadmium, selenium, and lead in decreasing concentrations, all stabilized in 5 percent HNO3 matrix.
This standard is ideal for validating instrument performance, ensuring accuracy in quantitative elemental determinations, and establishing traceability for environmental, industrial, and research laboratories. It is designed to meet stringent analytical requirements and is compatible with a wide range of PerkinElmer, Agilent, and other major brands of atomic absorption and inductively coupled plasma instruments. The comprehensive multi-element formulation allows laboratories to streamline calibration protocols, maintain regulatory compliance, and increase efficiency by minimizing the need for multiple single-element standards. This solution pairs effectively with quality control materials and calibration blanks for reliable and reproducible results in trace metal analysis.