{"product_id":"cobetter-bml50lt41y1k","title":"Cobetter, BML50LT41Y1K, Lifecube™ ML Single-use Mixing Bag Sterile by Gamma Irradiation","description":"\u003cp\u003eCheck this product with a package size of 50 L \/ Top: an inlet + a 4\" powder port.  Side: a sampling port.  Bottom: a drain\/outlet. \/ None on Iright. Cobetter Lifecube Single-use Mixing Bags offer no-clean, many specifications, pre-sterilization, easy to install and flexibility of use, etc. The Lifecube Single-use Mixing bags are made of multi-layer co-extrusion film, feature good physical and chemical properties and extremely low gas permeability. Lifecube Single-use Mixing bags are suitable for a wide range of mixing steps in upstream and downstream processes.\u003cbr\u003e\nSpecifications\u003c\/p\u003e\n\n\u003cp\u003eMaterials\u003cbr\u003e\nMixing Type\u003cbr\u003e\nCobetter Lifecube ML Single-use Mixing Bags\u003cbr\u003e\nMaterial\u003cbr\u003e\nCobetter Topene RB Film\u003cbr\u003e\nImpeller(MPL)\u003cbr\u003e\nMaterials of Construction\u003cbr\u003e\nMain part\/ Welding pad\/ Plug: HDPE\u003cbr\u003e\nVolume\u003cbr\u003e\n20L - 1000L\u003c\/p\u003e\n\n\u003cp\u003eTotal Fluid Contact Area\u003cbr\u003e\n706 cm²\u003cbr\u003e\nMain Height*\u003cbr\u003e\n8 cm\u003cbr\u003e\nSpeed**\u003cbr\u003e\n≤ 210 rpm\u003cbr\u003e\nTubing and Port\u003cbr\u003e\nInlet\u003cbr\u003e\n50\/100\/200 L: 150cm 3\/8\" ID x 5\/8\" OD Lifemeta™ STT Pt-cured Silicone tubing + ECS Female Quick Connector;\u003cbr\u003e\n500\/1000 L: 150cm 1\/2\" ID x 3\/4\" OD Lifemeta™ STT Pt-cured Silicone tubing + ECM Female Quick Connector.\u003c\/p\u003e\n\n\u003cp\u003eOutlet\u003cbr\u003e\n50\/100\/200 L: 150cm 3\/8\" ID x 5\/8\" OD Lifemeta™ STT Pt-cured Silicone tubing + ECS Male Quick Connector with plug;\u003cbr\u003e\n500\/1000 L: 150cm 1\/2\" ID x 3\/4\" OD Lifemeta™ STT Pt-cured Silicone tubing + ECM Male Quick Connector with plug.\u003cbr\u003e\nSampling\u003cbr\u003e\n20cm 1\/4\" ID x 7\/16\" OD Lifemeta™ STT Pt-cured Silicone tubing + Needlefree Swabable Valve\u003cbr\u003e\nPowder Port\u003cbr\u003e\n4\" TC (including silicone gasket, blind cap and tri-clamp)\u003cbr\u003e\nSterility\u003cbr\u003e\nDelivery Condition\u003cbr\u003e\nSterile\u003cbr\u003e\nSterilization Method\u003cbr\u003e\nGamma Irradiation\u003cbr\u003e\nPackage\u003cbr\u003e\nPack Size\u003cbr\u003e\n1\/pack\u003cbr\u003e\nNote:\u003cbr\u003e\n*Height from the welding plate to the top of the impeller; \u003cbr\u003e\n**For reference only. The mixing speed is different from bag specifications, stirring volumes, solutions and brand of mixers. Please confirm the mixing speed and efficiency according to the actual situation.\u003cbr\u003e\nFeatures\u003cbr\u003e\nMagnetic suction\/magnetic suspension mixing, integrated\/split system, compatible with other brands\u003cbr\u003e\nFast installation, well mixing run and easy setup\u003cbr\u003e\nDouble-layer packaging, sterilized by 25~45 kGy gamma irradiation\u003cbr\u003e\nMany specifications, meeting a variety of preparation applications\u003cbr\u003e\nCustomized bag sizes, flexibly match different specification of containers\u003cbr\u003e\nCustomized Tubings, connectors and filters\u003cbr\u003e\nSensors can be customized to allow on-line monitoring during the process\u003cbr\u003e\nHardware with audit trail and automatic management functions available\u003cbr\u003e\nApplications\u003cbr\u003e\nBuffer and culture medium preparation\u003cbr\u003e\nSemi-finished products preparation\u003cbr\u003e\nBatch mixing\u003cbr\u003e\nQuality Assurance\u003cbr\u003e\nISO 9001:2015 quality management system\u003cbr\u003e\nISO Class 4.8\/ ISO 7\/ ISO 8 cleanroom production\u003cbr\u003e\n100% leak testing\u003cbr\u003e\nADCF raw materials, complies with FDA 21 CFR Part 177-182 (Indirect food addictives)\u003cbr\u003e\nMeet the requirement of current USP \u0026lt;87\u0026gt; Class VI, Biological Reactivity Test, In Vitro\u003cbr\u003e\nMeet the criteria of the current USP \u0026lt;88\u0026gt; Class VI, Biological Reactivity Test In Vitro\u003cbr\u003e\nAqueous extraction contains \u0026lt; 0.25 EU\/mL as determined by Limulus Amebocyte Lysate (LAL), USP \u0026lt;85\u0026gt;\u003cbr\u003e\nParticulate matter in the product eluent meets the requirements in USP \u0026lt;788\u0026gt; for large volume parenterals\u003cbr\u003e\nVerify gamma irradiation dose according to ISO 11137\u003cbr\u003e\nConfiguration Options\u003cbr\u003e\n*Contact us for other configuration options. Q: What are the applicable conditions for the use of mixing bags?\u003cbr\u003e\n1. Liquid-liquid mixing, solid-liquid mixing, such as media preparation, buffer preparation, intermediate product preparation, mixing of liquid collections from different batches, and so on.\u003cbr\u003e\n2. The recommended temperature range is usually 0-40°C, pH range is 2.5-11.\u003cbr\u003e\n3. Common specifications for mixing bags are 50L, 100L, 200L, 500L, 1000L, 1500L, 2000L, with a minimum nominal stirring volume of 20%.\u003cbr\u003e\nQ: What is the minimum volume specification for the mixing bag?\u003cbr\u003e\nCurrently, we can provide mixing bags in a 20L specification, and the minimum mixing volume can be achieved at 4L. We also offer matching hardware systems (MG series).\u003cbr\u003e\nAll MP bags have the same specifications for the impeller.\u003cbr\u003e\nThe MG impellers come in three sizes: 100\/50\/20.\u003cbr\u003e\nThe MK impellers are available in different sizes for volumes below 100, 100-200, and 500-1000.\u003cbr\u003e\nQ: Will a single-use system that has been irradiated have any impact on the product? Can irradiation residues be detected in the irradiated items?\u003cbr\u003e\nNo. The irradiation dose is validated to ensure sterilization effectiveness. Moreover, the irradiation process only involves energy absorption and does not involve direct contact with the radiation source. Therefore, there are no issues of irradiation residues in the disposable system.\u003cbr\u003e\nQ: What is the minimum mixing volume for mixing bags?\u003cbr\u003e\nGenerally, the minimum mixing volume for mixing bags is 20% of the nominal volume of the bag, assuming complete mixing. However, if the aim is to achieve mixing effects, then a liquid level that reaches the height of the paddle blades is generally sufficient.\u003cbr\u003e\nQ: What is the maximum mixing volume for mixing bags?\u003cbr\u003e\nTypically, the maximum filling volume for mixing bags is 110% of the nominal volume. However, due to gas entering during the liquid filling process, the actual volume may be slightly smaller. If the liquid level is close to the maximum filling volume, it is recommended to add a vent filter.\u003cbr\u003e\nQ: What is the installation process for single-use storage bags and mixing bags?\u003cbr\u003e\nWhen customers receive the bags, they need to remove the two layers of outer packaging. The films are attached together.\u003cbr\u003e\nFirst, position the bag right and stretch the drainage tube out of the drainage hole of the container. If there is a mixing paddle, align it with the magnetic head position, adjust the bag.\u003cbr\u003e\nThen fill the liquid while adjusting the position and angle of the bag to fit the container. If it is a square container, the weld position of the bag is different, so it is necessary to confirm the top and bottom first, and then operate. If it is a round container, it is necessary to adjust the bag to ensure that it is vertically placed and the bag body is in contact with the wall of the drum.\u003cbr\u003e\nAll adjustments must be made as quickly as possible during the liquid filling process. After the liquid filling is completed, the bag is too heavy to adjust (do not pull the film, tube, etc.). If the final fit is poor, If the final fit is poor, it increases the risk of damage. (Paper instructions are included with the shipment.)\u003cbr\u003e\nQ: What is the difference between magnetic stirring and magnetic levitation stirring?\u003cbr\u003e\nMagnetic stirring: MP\/MG series, with sufficient power and strong shear force, good mixing effect, and a rotation speed of usually ≤250rpm; Magnetic levitation stirring: ML\/MK\/MKP\/MS series, with gentle stirring, low shear force, a rotation speed of 250rpm-1000rpm, zero friction, but high cost. There is no absolute good or bad, and the choice should be made based on the application.\u003cbr\u003e\nQ: Can single-use products be irradiated again after expiration?\u003cbr\u003e\nNo, the validation test of single-use products is based on one-time irradiation, and the strength of the material and risks such as E\u0026amp;L have not been systematically validated for multiple irradiations.\u003c\/p\u003e","brand":"Cobetter","offers":[{"title":"Default Title","offer_id":46778395033769,"sku":"BML50LT41Y1K","price":0.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/iright.com\/products\/cobetter-bml50lt41y1k","provider":"Iright","version":"1.0","type":"link"}