{"product_id":"revvity-al3056c","title":"Revvity, AL3056C, AlphaLISA Human Fibronectin Detection Kit, 500 Assay Points","description":"\u003cp\u003eOverview\u003cbr\u003e\nFormats:\u003c\/p\u003e\n\n\u003cp\u003eOur 100 assay point kit allows you to run 100 wells in 96-well format, using a 100 µL reaction volume (10 µL of sample).\u003cbr\u003e\nOur 500 assay point kit allows you to run 500 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).\u003cbr\u003e\nOur 5,000 assay point kit allows you to run 5,000 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).\u003c\/p\u003e\n\n\u003cp\u003eFeatures:\u003c\/p\u003e\n\n\u003cp\u003eNo-wash steps, no separation steps\u003cbr\u003e\nELISA alternative technology\u003cbr\u003e\nSensitive detection\u003cbr\u003e\nBroad sample compatibility\u003cbr\u003e\nSmall sample volume\u003cbr\u003e\nResults in less than 3 hours\u003cbr\u003e\nHalf the time of an ELISA assay\u003c\/p\u003e\n\n\u003cp\u003eAlphaLISA technology allows the detection of molecules of interest in buffer, cell culture media, serum and plasma in a highly sensitive, quantitative, reproducible and user-friendly mode. In an AlphaLISA assay, a Biotinylated Anti-Analyte Antibody binds to the Streptavidin-coated Alpha Donor beads, while another Anti-Analyte Antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads provokes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.\u003cbr\u003e\nFibronectin is a large glycoprotein of the extracellular matrix that exists in two forms: insoluble (cellular) and as a soluble plasma protein. The primary functions of fibronectin are its involvement in cell adhesion, growth, migration, and differentiation. Fibronectin is known to contribute to the wound healing process where it will accumulate at the site of injury to help form blood clots and aid in the development of new tissues. Fibronectin levels in serum and plasma have been identified to increase significantly after major traumas. Further, Fibronectin levels have been observed to be significantly altered in disease states of certain types of cancer and also diabetes mellitus. This AlphaLISA kit has been designed to detect and quantify Human Fibronectin in human serum and cell culture supernatants.\u003cbr\u003e\nHow it works\u003cbr\u003e\nPrinciple of the AlphaLISA assay\u003c\/p\u003e\n\n\n    \u003cp\u003eThe AlphaLISA assay is based on an AlphaLISA sandwich immunoassay involving a biotinylated anti-analyte antibody bound to Streptavidin-coated AlphaLISA Donor beads and an anti-analyte antibody conjugated to AlphaLISA Acceptor beads. Both antibodies are directed against the analyte of interest. In the presence of the target, both antibodies bind to analyte and the beads come into proximity. The excitation of the Donor beads provokes the release of singlet oxygen molecules that triggers a cascade of energy transfer within the Acceptor beads, resulting in emission with λmax at 615 nm. The intensity of the signal is directly proportional to the concentration of analyte present in the sample.\u003c\/p\u003e\n\n\n\n  \u003cbr\u003e\n        \n\n\n\t\u003cbr\u003e\n  \u003cbr\u003e\n        \u003cbr\u003e\n  \n\n      \u003cbr\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n    \u003cbr\u003e\n      \u003cbr\u003e\n        \u003cbr\u003e\n        \u003cbr\u003e\n        \u003cbr\u003e\n        \u003cbr\u003e\n      \u003cbr\u003e\n    \n\n    \u003cbr\u003e\n      \n\n      \u003cbr\u003e\n        \n\n      \u003cbr\u003e\n    \n\n  \n\n\n\n\n\n    \u003cp\u003e \u003c\/p\u003e\n\n\n\n\n            \u003cp\u003eProtocol of the AlphaLISA assay\u003c\/p\u003e\u003cbr\u003e\n        \n\n            \u003cp\u003eThe AlphaLISA assay can be run in a 96- or 384-well detection plate (50 µL final). As described here, samples or standards are dispensed directly into the assay plate for the detection of the analyte of interest by AlphaLISA reagents. No washing steps are needed. The protocol can be further miniaturized or upscaled by simply resizing each addition volume proportionally. \u003cbr\u003e\nApplication-Protein Quantification\u003cbr\u003e\nAutomation Compatible-Yes\u003cbr\u003e\nBrand-AlphaLISA\u003cbr\u003e\nDetection Modality-Alpha\u003cbr\u003e\nDynamic Range-242 - 3,000,000 pg\/mL\u003cbr\u003e\nLimit of Detection-242 pg\/mL\u003cbr\u003e\nLimit of Quantification-785 pg\/mL\u003cbr\u003e\nProduct Group-Kit\u003cbr\u003e\nSample Volume-5 µL\u003cbr\u003e\nShipping Conditions-Shipped in Blue Ice\u003cbr\u003e\nTarget-Fibronectin\u003cbr\u003e\nTarget Class-Biomarkers\u003cbr\u003e\nTarget Species-Human\u003cbr\u003e\nTechnology-Alpha\u003cbr\u003e\nTherapeutic Area-Oncology\u003cbr\u003e\nUnit Size-500 assay points\u003c\/p\u003e","brand":"Revvity","offers":[{"title":"Default Title","offer_id":46774532473001,"sku":"AL3056C","price":0.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/iright.com\/products\/revvity-al3056c","provider":"Iright","version":"1.0","type":"link"}