{"product_id":"revvity-al363hv","title":"Revvity, AL363HV, AlphaLISA Human Albumin Biotin Free Detection Kit, 100 Assay Points","description":"\u003cp\u003eOverview\u003cbr\u003e\nThe biotin-free kit uses anti-DIG (anti-Digoxin) Donor beads instead of streptavidin Donor beads, which makes the kit compatible with high-biotin culture media and other sample types that contain high levels biotin (including brain\/liver tissue extracts, milk and eggs).\u003cbr\u003e\nFeatures:\u003c\/p\u003e\n\n\u003cp\u003eNo-wash steps, no separation steps\u003cbr\u003e\nCompatible with high biotin samples, including RPMI and high-biotin tissue extracts\u003cbr\u003e\nELISA alternative technology\u003cbr\u003e\nSensitive detection\u003cbr\u003e\nBroad sample compatibility\u003cbr\u003e\nResults in less than 3 hours\u003c\/p\u003e\n\n\u003cp\u003eFormats:\u003c\/p\u003e\n\n\u003cp\u003eOur HV (100 assay point) kits allow you to run 100 wells in 96-well format, using a 100 µL reaction volume (10 µL of sample).\u003cbr\u003e\nOur 500 assay point kit allows you to run 500 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).\u003cbr\u003e\nOur 5,000 assay point kit allows you to run 5,000 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).\u003c\/p\u003e\n\n\u003cp\u003eHuman serum albumin (HSA) is a 66 kDa protein produced by the liver. HSA constitutes two thirds of the protein mass of serum and plays a key role in the transport of small molecules in the blood such as fatty acids, vitamins, hormones, divalent cations, and drugs. Another important function of HSA is to maintain osmotic pressure and pH in the blood. HSA is an important biomarker in kidney disease. In albuminuria, albumin is not reabsorbed properly by kidney glomeruli and is excreted in the urine. Generally, in hypoalbuminemia, a lower level of albumin in serum can be explained by a kidney disease, poor liver function, or inflammation.\u003cbr\u003e\nAlphaLISA technology allows the detection of molecules of interest in a no-wash, highly sensitive, quantitative assay. In an AlphaLISA biotin-free assay, a DIG-labeled anti-analyte antibody binds to the anti-DIG-coated Donor beads while another anti-analyte antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads causes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.\u003cbr\u003e\nHow it works\u003cbr\u003e\nPrinciple of the AlphaLISA biotin-free assay\u003c\/p\u003e\n\n\n    \u003cp\u003eThe AlphaLISA Biotin-Free assay is based on an AlphaLISA sandwich immunoassay involving a digoxigenin anti-analyte antibody bound to anti-DIG AlphaLISA Donor beads and an anti-analyte antibody conjugated to AlphaLISA Acceptor beads. Both antibodies are directed against the analyte of interest. In the presence of the target, both antibodies bind to analyte and the beads come into proximity. The excitation of the Donor beads provokes the release of singlet oxygen molecules that triggers a cascade of energy transfer within the Acceptor beads, resulting in emission with λmax at 615 nm. The intensity of the signal is directly proportional to the concentration of analyte present in the sample.\u003c\/p\u003e\n\n\n\n  \u003cbr\u003e\n        \n\n\n\t\u003cbr\u003e\n  \u003cbr\u003e\n        \u003cbr\u003e\n  \n\n      \u003cbr\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n    \u003cbr\u003e\n      \u003cbr\u003e\n        \u003cbr\u003e\n        \u003cbr\u003e\n        \u003cbr\u003e\n        \u003cbr\u003e\n      \u003cbr\u003e\n    \n\n    \u003cbr\u003e\n      \n\n      \u003cbr\u003e\n        \n\n      \u003cbr\u003e\n    \n\n  \n\n\n\n\n\n    \u003cp\u003e \u003c\/p\u003e\n\n\n\n\n            \u003cp\u003eProtocol of the AlphaLISA biotin-free assay\u003c\/p\u003e\u003cbr\u003e\n        \n\n            \u003cp\u003eThe AlphaLISA Biotin-Free assay can be run in a 96- or 384-well detection plate (50 µL final). As described here, samples or standards are dispensed directly into the assay plate for the detection of the analyte of interest by AlphaLISA reagents. No washing steps are needed. The protocol can be further miniaturized or upscaled by simply resizing each addition volume proportionally. \u003cbr\u003e\nApplication-Protein Quantification\u003cbr\u003e\nAutomation Compatible-Yes\u003cbr\u003e\nBrand-AlphaLISA\u003cbr\u003e\nDetection Modality-Alpha\u003cbr\u003e\nDynamic Range-102 - 1,000,000 pg\/mL\u003cbr\u003e\nLimit of Detection-102 pg\/mL\u003cbr\u003e\nLimit of Quantification-346 pg\/mL\u003cbr\u003e\nProduct Group-Kit\u003cbr\u003e\nSample Volume-10 µL\u003cbr\u003e\nShipping Conditions-Shipped in Blue Ice\u003cbr\u003e\nTarget-Albumin\u003cbr\u003e\nTarget Class-Biologics\u003cbr\u003e\nTarget Species-Human\u003cbr\u003e\nTechnology-Alpha\u003cbr\u003e\nUnit Size-100 assay points\u003c\/p\u003e","brand":"Revvity","offers":[{"title":"Default Title","offer_id":46774534602921,"sku":"AL363HV","price":0.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/iright.com\/products\/revvity-al363hv","provider":"Iright","version":"1.0","type":"link"}