BRAND / VENDOR: Thermo Fisher

Thermo Fisher, 88340, Pierce™ Triple Quadrupole Calibration Solution, extended mass range

CATALOG NUMBER: 88340

Regular price$0.99
/
Shipping calculated at checkout.
  • 99 items in stock
  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

Pierce™ Triple Quadrupole Calibration Solution, extended mass range The Thermo Scientific™ Pierce™ Triple Quadrupole Calibration Solution, Extended Mass Range, is a mixture of 14 highly pure, ionizable components (mass range: 69 m/z to 2800m/z) designed for both positive and negative ionization calibration of Thermo Scientific Triple Stage Quadrupole instruments.
•Improved mass accuracy—extended mass range designed to improve mass accuracy when compared to existing calibration solutions
•Positive and negative mode calibration—single formulation with extended mass ranges for both ionization calibration modes
•Highly validated—high-quality, rigorously tested formulation with lot-specific certificates of analysis
•Ready to use—reference standard may be directly loaded into a syringe and injected into the instrumentThe Pierce Triple Quadrupole Calibration Solution is a ready-to-use formulation that has been optimized for both positive and negative ionization calibration of instruments. The extended range masses (69 m/z to 2800m/z) improve performance of the Thermo Scientific Quantiva™ and Endura™ Triple Quadrupole mass spectrometers. Additionally, the Triple Quadrupole Calibration Solution, Extended Mass Range, is manufactured at an ISO 9001 facility and each lot is quality controlled with strict specifications. The stable solution is provided in a leak-proof, high-purity PTFE bottle.
The Pierce Triple Quadrupole Calibration Solution, Extended Mass Range, formulation contains 14 compounds that are ionizable in both positive and negative modes for instrument calibration. The formulation has been specifically optimized for use with the TSQ Endura™ Series and TSQ Quantiva™ Series instruments. The calibration solution is also compatible with the TSQ Quantum™ Series#, TSQ Discovery™ Series#, TSQ Quantum Ultra™ Series#, TSQ Quantum Access™ Series#, and TSQ Vantage™ Series# instruments using the list of recommended masses.
Positive mode (m/Z): 69.
0447, 142.
1590, 322.
0481, 622.
0289, 922.
0098Negative mode (m/Z): 59.
0128, 112.
9845, 301.
9970, 601.
9779, 1033.
9870For the calibration procedure use:TSQ Series Getting Started Guide (70111-97152)Final Product Type: Peptides, Small Molecules
For Use With (Equipment): Mass Spectrometer
Quantity: 10 mL
Workflow Step: Calibration
Detection Method: Mass Spectrometry
Form: Liquid
Product Line: Pierce™
Product Type: Calibration Solution
Starting Material: Peptides, Small Molecules
Unit Size: Each

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)