Filtern

    Thermo Fisher Chromatography Supplies for LC & GC

    347 products

    You need dependable chromatography consumables that keep your methods consistent from sample prep to final detection. This Collection curates Thermo Fisher supplies—HPLC/UHPLC and GC columns, autosampler vials and caps, syringe filters, SPE cartridges, GC liners and septa, tubing and fittings—so you can choose quickly, quote fast with Iright, and stay focused on results. As a distributor, Iright can source a wide range of Thermo Fisher products and documentation to support regulated workflows.

    What You’ll Find: LC/GC Chromatography Supplies

    This Collection spans the full workflow, from filtration and SPE through injection and separation to routine maintenance. Use it as your central hub to browse by technique, refine by dimensions and materials, and confirm instrument compatibility before you order.

    • LC/UHPLC columns & guard columns (e.g., Hypersil GOLD C18 in multiple lengths, IDs, and particle sizes).

    • GC capillary columns & inlet consumables (liners, septa such as BTO/TR-Green).

    • Autosampler vials, caps & septa (SureSTART levels for everyday to high-performance LC-MS/GC-MS).

    Thermo Fisher SureSTART
    • Syringe/disc filters (PES/PTFE/Nylon/PVDF; 0.22 µm/0.45 µm). 

    • SPE cartridges & plates (SOLA polymeric, SCX/SAX mixed-mode options).

    • Tubing, fittings, and ferrules for routine upkeep and leak-free connections.

    How to Choose Chromatography Consumables (LC/GC)

    Small decisions—chemistry, particle size, septa material, membrane type—have outsized effects on durability, sensitivity, and reproducibility. Use the path below to match analyte, matrix, and instrument to the right Thermo Fisher part.

    • LC/UHPLC columns: Start from analyte polarity and method goals, then select the stationary phase (e.g., C18 vs. HILIC), particle size (1.9–5 µm), and dimensions that meet your backpressure budget. Hypersil GOLD offers a broad matrix of lengths/IDs for scalable methods.

    • GC inlet consumables: Pick liners by injection mode (split/splitless/PTV) and septa by temperature/bleed class (BTO up to 400 °C; TR-Green low-bleed silicone). Replace on a schedule to avoid drift.

    • Autosampler vials & caps: Choose vial volume and thread (e.g., 2 mL, 9-425), pair with low-bleed septa, and select performance level by application sensitivity (SureSTART Level 1–3).

    • Syringe filters: Match solvent and membrane (PES for aqueous, PTFE for strong organics), then pick pore size (0.22 µm for LC-MS; 0.45 µm for HPLC UV).

    • SPE cartridges/plates: Map matrix and analyte to sorbent (HRP reversed-phase, SCX/SAX mixed-mode), and size the cartridge for load and throughput.

    Compatibility at a Glance: Instruments, Sizes & Threads

    Before you add to the cart, confirm system pressure limits, tray dimensions, and inlet geometry. The quick grid below summarizes typical fit, then you can drill into a product card for precise specs.

    Use Case Product Type Key Specs Typical Compatibility
    LC method development Hypersil GOLD HPLC column 50–250 mm length, 1–4.6 mm ID, 1.9–5 µm HPLC/UHPLC systems within rated pressure; standard 10–32 fittings.
    GC volatile analysis BTO/TR-Green septa 9–17 mm; up to 400 °C; low-bleed silicone Fits standard GC inlets; choose the size for your inlet cap. 
    Autosampler workflows SureSTART 2 mL vials & caps 9-425 screw; Level 1–3 performance tiers Common LC/GC autosamplers; verify tray/height spec.
    LC/GC sample cleanup Choice/Titan3 syringe filters PES/PTFE/PVDF/Nylon; 0.22/0.45 µm Inline syringe filtration before injection; choose a membrane for solvent.
    Bioanalytical prep SOLA SPE cartridges/plates HRP, SCX, SAX; fritless design Plate or cartridge formats for high-throughput labs.

    Featured Chromatography Products & Key Specs

    Below are representative, commonly requested SKUs to anchor your selection process. Open the product page or ask Iright to confirm pack sizes and lead times for your region.

    SKU Product Name Key Specs Typical Use Options/Pack
    25005-102130 Hypersil GOLD C18 column 100 mm × 2.1 mm, 5 µm Robust small-molecule work; general HPLC methods Multiple lengths/IDs available.
    25003-052130 Hypersil GOLD C18 column 50 mm × 2.1 mm, 3 µm Fast gradients; tighter peaks at moderate pressure Broad size matrix.
    6ASV9-1P SureSTART 2 mL screw-top vial (Level 2) Glass; performance level for high-throughput QA/QC Routine LC/GC; reliable sealing See pack sizes on the product page.
    CHSV9-10P SureSTART 2 mL screw-top vial (Level 1) Clear glass; everyday analysis General HPLC/GC injections 100/Pk; additional case sizes available.
    6PRV11-1P SureSTART 2 mL snap-top vial (Level 3) High-performance, LC-MS-ready High-sensitivity methods 100/Pk (also 1000/5000).
    CH2225-PES Choice PES syringe filter 0.22 µm, PES membrane (example variant) Aqueous filtration before LC Sizes/membranes vary; confirm diameter.
    60109-001 SOLA HRP SPE cartridge Reversed-phase polymeric; fritless design Bioanalytical cleanup; consistent recoveries Sorbent chemistries and loads available.
    31303240 BTO GC septa 9 mm; up to 400 °C; low bleed GC-MS inlet sealing at high temp 50/pk (glass jar) and blister options.

    Method-Ready Bundles for LC/GC Workflows

    When you’re standing up a new assay or refreshing a platform, curated bundles reduce back-and-forth and cut setup time. Tell us your analytes, matrices, and instrument, and we’ll assemble a small-to-large kit with documentation.

    • LC method development set: Hypersil GOLD C18 columns in two lengths and particle sizes, plus matched guard cartridges for rapid scouting.

    • GC volatiles starter kit: Capillary column (spec per method), deactivated liner, and BTO septa for high-temperature split/splitless injections.

    • Sample-prep essentials: Choice/Titan3 syringe filters (0.22 µm/0.45 µm) and SOLA SPE (HRP or mixed-mode) sized to your throughput.

    Quality, Documentation & Compliance (CoA/SDS)

    Consistency and traceability matter as much as separation performance. For each item, you can request batch documentation and cleanliness details to satisfy QA and regulatory reviews.

    Iright provides CoA/CoC and SDS where applicable, and will align vial/septa materials, SPE sorbents, and column chemistries with your method’s compliance context (e.g., LC-MS/GC-MS low-bleed, low-adsorption requirements). SureSTART performance levels map to typical sensitivity tiers, and SOLA’s fritless polymeric format reduces channeling/voids that cause re-runs.

    FAQs: Columns, Vials, Filters & SPE

    A short FAQ cuts the time from cart to first injection. If you don’t see your case here, send us your method notes and we’ll reply with a short list.

    Q1. Can I run a UHPLC column on a conventional HPLC?
    Yes—check the system’s pressure limit and expected backpressure for the chosen ID/length/particle size; pair with compatible fittings and consider guard columns for dirty matrices. Hypersil GOLD offers multiple particle sizes to balance speed and pressure.

    Q2. What vial/septa level should I choose for LC-MS?
    Use SureSTART Level 3 for high-sensitivity LC-MS, Level 2 for high-throughput QA/QC, and Level 1 for everyday analysis. Combine with low-bleed caps and proper thread (e.g., 9-425) to minimize extractables.

    Q3. Which syringe filter membrane fits my solvent?
    Use PES for aqueous samples, PTFE for aggressive organics, and PVDF/Nylon for general use; pick 0.22 µm for LC-MS and 0.45 µm for HPLC/UV unless your method specifies otherwise.

    Q4. Why SOLA instead of conventional SPE?
    SOLA’s fritless polymeric design reduces voiding and channeling, improving reproducibility and minimizing repeat extractions in high-throughput environments.

    Talk to Iright: Quotes, Stock & Technical Support

    Share your target analytes, sample matrix, instrument model, and any required column/vial standards. Iright will confirm SKU/pack sizes, check stock and lead time, attach CoA/SDS, and suggest a method-ready bundle you can deploy with minimal tweaking. If you maintain a preferred vendor list or validation plan, we’ll map Thermo Fisher alternatives one-for-one to keep your documentation tidy.