Filtern

    Thermo Fisher Microplates for ELISA, Fluorescence & Imaging

    901 products

    Thermo Fisher microplates bring together reliable surfaces, clear optical paths, and SBS-standard footprints so you can run ELISA, fluorescence/luminescence assays, cell imaging, HTS screens, and routine storage with confidence. On this Collection page you’ll find application-driven guidance, surface and format comparisons, and representative SKUs verified against Thermo Fisher’s catalog. As an authorized distributor, Iright can source a broad range of Thermo Fisher (Nunc™/Thermo Scientific™) plates and accessories to match your workflow.

    How to Choose by Application (ELISA, Fluorescence, Imaging, HTS, Storage)

    Choosing starts from the assay. Plate color and surface chemistry directly affect signal, background, and binding performance; well geometry and material affect volume recovery and automation. Use the quick map below to align each application with the most suitable plate style before you drill into surfaces and formats.

    • ELISA / Solid-phase assays → Clear polystyrene immuno plates with high-binding surfaces (e.g., MaxiSorp™) for protein adsorption and consistent colorimetric reads.

    Thermo Fisher MaxiSorp
    • FluorescenceBlack plates minimize crosstalk and autofluorescence; optical-bottom variants support cell-based imaging.

    • LuminescenceWhite plates maximize reflectance for higher signal; optical bottoms support microscopy when needed. 

    • Cell culture & imaging → Nunclon™ Delta TC-treated surfaces improve adhesion; Edge 2.0 designs reduce edge effects during long incubations.

    • Compound/DNA storage & sample processing → Polypropylene (PP) low-binding plates (including DeepWell™) offer solvent resistance and complete recovery.

    Thermo Fisher Nunclon™ Delta

    Surface Types Explained: MaxiSorp vs PolySorp vs TC-Treated vs Low-Binding

    Surfaces that look alike can behave very differently. High-binding immuno surfaces adsorb proteins for ELISA; hydrophilic TC-treated surfaces favor adherent cells; PP “low-binding” storages minimize biomolecule loss. The table clarifies practical fit so you pick once and run with fewer repeats.

    Surface type Typical use Binding/interaction Notes
    MaxiSorp™ Protein ELISA/antibody capture Energy-treated high protein binding Classic clear/black immuno plates; legacy SKUs exist; see current immuno plate families.
    PolySorp™ Hydrophobic ligands/antigens Hydrophobic binding Often used when protein adsorption needs are lower or more selective.
    Nunclon™ Delta (TC-treated) Adherent cell culture, imaging Hydrophilic, promotes adhesion Offered across 96/384-well and Edge 2.0 formats to reduce edge effects.
    Low-binding PP Storage/processing of DNA, proteins, and solvents Minimizes adsorption Polypropylene plates tolerate solvents; shared-wall DeepWell variants increase well diameter for mixing.
    Thermo Fisher PolySorp

    Formats & Materials: 96/384/1536-Well, Black/White/Clear, Bottoms & Volume

    Selecting a format balances throughput, optics, and instrument compatibility. Standard 96-well suits most ELISAs; 384/1536 drive HTS density; black/white/clear decide detection physics; and optical polymer bottoms enable microscopy without leaving microplate workflows. All plates conform to SBS/ANSI footprints for automation and readers.

    • Well densities: 96 for general assays, 384/1536 for HTS.

    • Colors: Clear (absorbance/ELISA), Black (fluorescence), White (luminescence).

    • Bottoms: Flat/U/V; optical polymer bottom or coverglass base for imaging and sensitive reads.

    • Materials: Polystyrene for assays/cell work; polypropylene for storage/solvents.

    Featured Thermo Fisher Microplates — Exact SKUs & Key Specs

    This short list highlights representative, widely used SKUs to anchor your selection. Each entry links to a distinct use case—immuno binding, optical imaging, TC culture, or low-binding storage—so you can map directly to your assay and platform. (More sizes/packaging exist under each family.)

    Product (family) Catalog No. Color / Bottom Surface Wells Typical use
    Clear Flat-Bottom Immuno 96-Well Plates 442404 Clear/flat Immuno (family options) 96 General ELISA & colorimetric assays.
    Clear Flat-Bottom Immuno 96-Well, PolySorp 475094 Clear/flat PolySorp 96 Hydrophobic binding ELISAs/ligands.
    Black 96-Well Immuno Plates, MaxiSorp 437111 Black/flat MaxiSorp 96 Low-background fluorescence ELISAs.
    96-Well Black Plate (non-treated) 237108 Black/flat Non-treated PS 96 Fluorescence assays; robotics-ready.
    96-Well White Plate (non-treated) 236108 White/flat Non-treated PS 96 Luminescence assays; high reflectance.
    Optical-Bottom 96-Well, Black, TC 165305 Black/optical Nunclon Delta (TC) 96 Cell-based imaging & FI/LI reads.
    Optical-Bottom 96-Well, White, TC 165306 White/optical Nunclon Delta (TC) 96 Imaging with luminescent detection.
    MicroWell 96-Well, Nunclon Delta, with lid 167008 Clear/flat TC-treated 96 Routine adherent culture & assays. 
    PP 96-Well Sample Processing & Storage 249944 Natural / V-bottom Polypropylene (low-binding) 96 DNA/protein storage & solvent use.
    DeepWell™ PP 96-Well (shared-wall) 95040452 Natural/deep Polypropylene 96 High-capacity storage & mixing.
    Edge 2.0 96-Well, Non-treated 267427 Clear/flat Non-treated 96 Reduces edge evaporation in long incubations.
    Edge 2.0 96-Well, TC-treated 167425 Clear/flat Nunclon Delta (TC) 96 Even viability across the plate; incubations.

    Accessories for Microplates: Lids, Adhesive & Heat-Sealing Films, Breathable Membranes

    Good plates need good closures. The right lid or film controls evaporation, preserves sterility, and protects optics. Choose sterile lids for culture and optical films for qPCR/imaging; use breathable membranes for gas exchange during growth or long incubations.

    • Microplate lids (sterile/non-sterile, 96/384): 250002 (sterile), 250003 (non-sterile), 264623 (96-well sterile, with condensation rings), 264611/264612 (384-well).

    • Adhesive/optical films: AB0558 (adhesive PCR seals), 4311971 (MicroAmp™ optical adhesive film for qPCR).

    • Breathable/vented seals: Nunc™ seals & foils range (e.g., 241205 rayon breathable; 5701TS1 polyester).

    Automation & Reader Compatibility: SBS Footprint, Barcodes, Optical Bottoms

    Automation demands consistent geometry, stiffness, and readout windows. Nunc microplates—including Edge 2.0—follow ANSI/SBS standards and are compatible with robotic liquid handlers, stackers, and Thermo plate readers (absorbance, FI, LI, TRF). Optical-bottom designs pair with imaging systems without sacrificing throughput.

    Implementation tips (brief):

    • Prefer skirted/rigid plates for pin tools and stackers; confirm barcode location for traceability.

    • Use black optical-bottom for fluorescence imaging; white optical-bottom for luminescence microscopy.

    • For long incubations, switch to Edge 2.0 to minimize edge effect, enabling all 96 wells (↑ throughput).

    Thermo Fisher Microplates: Frequently Asked Questions

    Q1. Black vs. white vs. clear—when to use each?

    Use clear for absorbance/colorimetric ELISAs, black for fluorescence to reduce crosstalk, and white for luminescence to boost signal via reflectance. Optical bottoms support microscopy in black/white plates.

    Q2. MaxiSorp vs. PolySorp—what’s the difference?

    MaxiSorp is an energy-treated high-protein-binding surface for ELISAs; PolySorp is more hydrophobic for ligands or when lower binding is desired. Both are part of Thermo’s immuno plate families.

    Q3. How do I reduce edge effects in cell-based assays?

    Use Nunc Edge 2.0 plates; fill the outer moat with sterile water or media to buffer evaporation and improve viability uniformity across wells.

    Q4. Which plates are for long-term or solvent exposure?

    Choose polypropylene (PP) storage or DeepWell plates for solvent resistance and low adsorption of DNA/proteins; combine with compatible sealing films.

    Q5. Are these plates automation-ready?

    Yes—Nunc microplates follow ANSI/SBS standards and are validated across Thermo readers and common liquid handlers; confirm specific stacker tolerances and barcodes when ordering.

    Request a Quote from Iright for Thermo Fisher Microplates

    Tell us your assay type, readout (Abs/FI/LI/TRF), well density, surface, and whether you need optical bottoms or Edge 2.0. Iright will match SKUs (e.g., 165305/165306 for imaging, 437111 for MaxiSorp ELISA, 249944/95040452 for storage) and propose lead-time/packaging options, plus lids/seals to fit your incubators and readers.

    Order Guidelines

    1. Price & Stock Available on Request. Click to send email to: service@iright.com

    2. Please DO NOT make any payment before confirmation.

    3. Minimum order value of $1,000 USD required.

    4. 100% prepayment required.

    Collaboration

    Tony Tang

    Email: Tony.Tang@iright.com

    Mobile/WhatsApp/Wechat: +86-17717886924