J&W VF-1ms GC Column, 20 m, 0.10 mm, 0.10 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.

Specifications:
Capillary Tubing: Fused Silica
Film Thickness: 0.1 µm
Format: 7 inch
GC Column Type: GC/MS
Inner Diameter (ID): 0.1 mm
Length: 20 m
Phase: VF-1ms
Polarity: Low Polarity
Temperature Range: -60 °C-325/350 °C
UNSPSC Code: 41115710
With Smart Key: No

**********The following product description is generated by AI and is for reference only. If you have any questions, please contact customer service.**********
The J&W VF-1ms GC column features a non-polar 100 percent dimethylpolysiloxane stationary phase, engineered to deliver reliable and accurate separation of volatile organic compounds. With dimensions of 20 meters in length, 0.10 mm internal diameter, and a 0.10 micron film thickness, it is ideally suited for high-resolution analyses requiring fast run times and exceptional efficiency. The configuration on a 7 inch cage makes it compatible with most gas chromatograph instrument platforms, including Agilent 7890, 8890, and earlier GC models, as well as systems from other leading manufacturers.

This capillary column is designed for routine and advanced analyses in environmental, petrochemical, food safety, pharmaceutical, and forensics labs. Its low bleed characteristics support sensitive detection with mass spectrometry, making it suitable for trace analysis and confirmation of target analytes. The VF-1ms is especially recommended for applications involving pesticides, semivolatiles, hydrocarbons, and flavor or fragrance compounds. It pairs well with standard non-polar reference columns and complements Agilent autosamplers and MS detectors for comprehensive workflow integration. Researchers benefit from consistent performance, thermal stability, and reproducible results, even with demanding or complex sample matrices.

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)