Waters, 186003030, XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 30 mm, 1/pk

CATALOG NUMBER: 186003030
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

이 사이트는 hCaptcha에 의해 보호되며, hCaptcha의 개인 정보 보호 정책 서비스 약관 이 적용됩니다.

Product Description

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 12 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 3.5 µm
Endfitting Type: Waters
Pore Size: 130 Å
Format: Column
Surface Area: 185
System: HPLC
Particle Technology: BEH
USP Classification: L1
Inner Diameter: 4.6 mm
Length: 30 mm
Carbon Load: 18 %
UNSPSC: 41115709
Brand: XBridge
Product Type: Columns
Units per Package: 1 pk

Additional Information
XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 30 mm, 1/pk Make use of the XBridge BEH C18 Column to increase output. This specific goal has been built into the design of the lab equipment. Whether you wish to build a cutting-edge LC/MS assay or a quality control approach, this lab equipment is appropriate. The XBridge BEH C18 Column was created to give better pH stability and, as a result, longer column lives. You can take advantage of assay robustness and improve column dependability by using the analytical column. Additionally, the XBridge BEH C18 Columns provide exceptional peak shape and peak capacity by increasing particle efficiency. The UltraPerformance LC technology can be seamlessly transitioned using the XBridge BEH C18 Column. The XBridge BEH C18 Column is a dependable and significant investment for any lab that helps you to face even the most challenging chromatographic difficulties because it offers unrivaled column longevity and the ability to work over an unequaled range of mobile phase pH and temperatures. The XBridge BEH C18 Column exhibits little retention loss and peak shape deterioration when compared to columns with traditional packing materials. This is due to the XBridge packing's exclusive end-capping and bonding techniques, which produce ligand stability and chromatographic repeatability at low pH. A workhorse for HPLC method development, the XBridge BEH C18 Column was developed. Because of this, the sorbent found in lab equipment can be employed across the whole pH range of the mobile phase. The trifunctionally linked C18 ligand gives you the widest usable pH range, better low pH stability, and extremely little column bleed, making it a universal column for the majority of HPLC separations. We recommend that you also use the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk in conjunction with the column in order to increase its serviceable lifetime. The cartridge is attached to the column and is manufactured using the exact same materials as the lab equipment. This ensures there is no drop in performance. The function of the carriage is to eliminate the presence of unwanted contaminants from the mobile phase.

FAQ
Across What pH Does The XBridge BEH C18 Column Operate? The Waters XBridge BEH C18 Column listed here offers a broad pH range of 1-12. Is There A Pressure Limit For The XBridge BEH C18 Column? This particular XBridge BEH C18 Column can tolerate a maximum of 6,000 psi (415 Bar) pressure.