Product Description
As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 12 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 5 µm
Endfitting Type: Waters
Pore Size: 130 Å
Format: Column
Surface Area: 185
System: HPLC
Particle Technology: BEH
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 100 mm
Carbon Load: 18 %
UNSPSC: 41115709
Brand: XBridge
Product Type: Columns
Units per Package: 1 pk
Additional Information
XBridge BEH C18 Column, 130Å, 5 µm, 2.1 mm X 100 mm, 1/pk Add the XBridge BEH C18 Column to your lab equipment collection as it is a workhorse for HPLC method development and can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand present in the XBridge BEH C18 Column will provide you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. Deliver reliable performance each time using the XBridge BEH C18 Column. Scientists at Waters know that reliable column performance is crucial for method reliability. This is why column manufacturing is carefully monitored and every step tightly controlled to maintain product reproducibility. We conduct multiple tests every step of the way, starting from raw material characterization to final batch analysis so that you get reliable results in every batch and column, no matter how many times you perform analysis. Since it is designed to deliver unequaled adaptability, the XBridge BEH C18 Column will enable you to maximize your productivity. Whether you need to create a cutting-edge LC/MS assay or a quality control method, the lab equipment will help you achieve your goals while improving pH stability. With the XBridge BEH C18 Column, you can be certain of increased column lifetime and enhanced column reliability while leveraging assay ruggedness. By opting for the use of the XBridge BEH C18 Column, you may achieve unrivaled peak form and peak capacity by increasing particle efficiency. Use the ionizable analyte in its most neutral state to enhance retention in the XBridge BEH C18 Column. Acidic mobile phases, for example, will have the best retention for an acidic molecule. With the rise of the mobile-phase pH, acidic chemical retention will decrease. In the same settings, however, basic compound retention will rise. Acidic mobile phases have the lowest retention, while high-pH mobile phases have the highest retention. The pH of the mobile phase has little influence on a neutral substance. Protect your analytical column from harm by investing in the XBridge BEH C18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pk.
FAQ
What Is The Maximum Pressure That The XBridge BEH C18 Column Can Take? The XBridge BEH C18 Column, as specified in the mentioned listing, is designed to operate efficiently even under high-pressure conditions, withstanding up to 6000 psi (415 Bar). This column's robust construction enables reliable performance and accurate results, making it suitable for demanding chromatographic applications.