Product Description
Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Bonding Technology: T3
Silanol Activity: Medium
Particle Shape: Spherical
Particle Size: 3 µm
Pore Size: 100 Å
Format: Sentry Guard Cartridge
Surface Area: 330
System: HPLC
USP Classification: L1
Inner Diameter: 4.6 mm
Length: 20 mm
Carbon Load: 14 %
UNSPSC: 41115709
Brand: Atlantis
Product Type: Guards
Units per Package: 2 pk
Additional Information
Atlantis T3 Sentry Guard Cartridge, 100Å, 3 µm, 4.6 mm X 20 mm, 2/pk The Waters Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds. It is, therefore, crucial to protect this lab equipment. The Waters Atlantis T3 Sentry Guard Cartridge was created to work with the Atlantis T3 Reversed-phase Liquid Chromatography Columns. Because it is built of the same packing materials as the analytical column, the lab equipment is tailored to give the same degree of performance. The Cartridge is a single piece that attaches to the inlet side of an Atlantis T3 Column To extend the life of your analytical column, use the Atlantis Silica T3 Guard Cartridge. The lab equipment complements the analytical column's performance by eliminating chemical and particle pollution from the mobile phase stream. Your UPLC analytical columns will last longer using the Atlantis T3 Sentry Guard Cartridge without affecting their chromatographic analytical performance. This is accomplished by eliminating undesirable contaminants from the columns while retaining separation efficiency in UPLC, UHPLC, and HPLC. Browse our website to learn more about the whole Waters product line. There are products to fulfill any analytical demand, as well as the research and technology that supports them. Additionally, you can shop for lab equipment on the website. We recommend that you also explore and invest in the Reversed-Phase QC Reference Material. At pH 7, the Reversed-Phase QC Reference Material contains uracil, butylparaben, naphthalene, propranolol, dipropyl phthalate, acenaphthene, and amitriptyline, among other chemicals. This standard mix should be used to confirm your analytical HPLC or UPLC system's benchmark performance. This QC Reference Material is a carefully prepared mixture that contains a void marker, as well as neutral, acidic, and basic substances. These chemicals were chosen after extensive testing and evaluation because they offer the benefits such as excellent benchmark, and outstanding UV peak shape, and they can be used on a number of columns.
FAQ
What Is The Atlantis T3 Sentry Guard Cartridge’s pH Range? The Atlantis T3 Sentry Guard Cartridge listed here is able to function well across the 2-8 pH range. Is There A Pressure Limit On The Atlantis T3 Sentry Guard Cartridge? The Atlantis T3 Sentry Guard Cartridge listed here is able to sustain a maximum pressure of up to 6000 psi (415 Bar).
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924