Iright
BRAND / VENDOR: Waters

Waters, 186004672, ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 3 mm X 50 mm, 1/pk

CATALOG NUMBER: 186004672
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

이 사이트는 hCaptcha에 의해 보호되며, hCaptcha의 개인 정보 보호 정책 서비스 약관 이 적용됩니다.

Product Description

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

Specifications
Chemistry: Phenyl
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 12 pH
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Bonding Technology: Phenyl-Hexyl
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 1.7 µm
Endfitting Type: Parker-style
Pore Size: 130 Å
Format: Column
Surface Area: 185
System: UPLC, UHPLC
Particle Technology: BEH
USP Classification: L11
Inner Diameter: 3 mm
Length: 50 mm
Carbon Load: 15 %
eCord: Yes
UNSPSC: 41115709
Brand: ACQUITY UPLC
Product Type: Columns
Units per Package: 1 pk

Additional Information
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 3 mm X 50 mm, 1/pk In addition to providing complementary selectivity to C18 stationary phases, particularly for polyaromatic compounds, the ACQUITY BEH Phenyl family of columns, including the Waters XBridge BEH Phenyl Column, also gives you the most chemically stable phenyl sorbent on the market. With the ACQUITY UPLC BEH Phenyl Column, you can get extremely minimal column bleed, lengthy column lives, and superb peak form. For the analysis of analytes with pore sizes of 130Å and 1.7 µm, the Waters ACQUITY UPLC BEH Phenyl Column indicated above is the best option. You can use a wide pH stability range with the 3 mm I.D. column that is listed. When compared to alternative phenyl columns that are currently on the market, the ACQUITY UPLC BEH Phenyl column offers exceptional batch-to-batch repeatability for all types of analytes. This is the outcome of thoroughly researched packaging materials that were created especially for use with the ACQUITY UPLC System. The tightest ISO 9001 requirements and exacting process control are used to produce these products. To ensure that you obtain lab equipment that provides outstanding reproducible performance, every batch of ACQUITY BEH packing material is also tested chromatographically with acidic, basic, and neutral analytes. The results are held to limited specification ranges. Each column is carefully evaluated before being given an eCord Intelligent Chip with a Performance Chromatogram and Certificate of Batch Analysis. Use the ACQUITY UPLC BEH Phenyl Column to reduce the possibility of technique variation due to variances brought on by chromatographic media batch or column inconsistency. You can take advantage of the phenyl-hexyl ligand's trifunctional bonding to enjoy the best chemical stability, repeatability, and peak shape available for all analytes. The phenyl ligand has stationary phases that complement straight-chain alkyl phases in terms of selectivity, especially for compounds with aromaticity brought on by pi-pi interactions. We recommend that you also learn more about and invest in the Reversed-Phase QC Reference Material .

FAQ
What Is The pH Range Offered By The ACQUITY UPLC BEH Phenyl Column? The Waters ACQUITY UPLC BEH Phenyl Column listed here is able to function well within the 1-12 pH range. What Is The Recommended Maximum Pressure For The ACQUITY UPLC BEH Phenyl Column? This particular ACQUITY UPLC BEH Phenyl Column can withstand a maximum of 18,000 psi (1240 Bar) pressure.