SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 5 µm
Endfitting Type: Waters
Pore Size: 100 Å
Format: Column
Surface Area: 340
System: HPLC
USP Classification: L1
Inner Diameter: 3 mm
Length: 150 mm
Carbon Load: 16 %
UNSPSC: 41115709
Brand: SunFire
Product Type: Columns
Units per Package: 1 pk
Additional Information
SunFire C18 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pk High-resolution, quick, and low-back pressure are all characteristics of the SunFire C18 Column. In addition to this, the lab equipment has excellent sensitivity, a big peak capacity, and barely any bleed, producing sharp peaks. The column can be used in numerous mass spectrometry applications because of its adaptability. These distinct properties make the lab equipment necessary for any lab. Use the SunFire C18 Column for general-purpose technique development at low pH. The C18 ligand in the SunFire C18 Column is incredibly retentive, especially for simple compounds. As a result, the lab's equipment is suitable for assessments of impurity profiles and purification. With the SunFire C18 Column, you also obtain the best particle and bonding expertise, resulting in an industry-leading chromatographic performance. The SunFire C18 Column is made to the highest standards utilizing stringent quality control procedures, much like the rest of our lab equipment. In-depth testing is done on the lab equipment to make sure it will give the stated quality. Our website contains further information about our research and the technical procedures used to produce our equipment. You can shop for lab equipment directly from our website, which also houses our online store. When compared to numerous established silica-based HPLC column brands, the SunFire C18 Column's superior low pH stability extends the column lifetime. The analytical column will also provide you with a dependable column that is very effective and sensitive, which is another benefit of adding it to your lab. The SunFire C18 Column is produced using proprietary, state-of-the-art silica synthesis, bonding, end-capping, and packing procedures to achieve this. Higher peak shape performance is provided by the novel bonding and end-capping technologies in combination with the sorbent of the lab equipment. You receive symmetrical peaks for better resolution and quantitation of acidic, neutral, and basic compounds at low and intermediate pH ranges. We recommend the use of the SunFire C18 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the column.
FAQ
Does The SunFire C18 Column Have Any pH Limits? This particular SunFire C18 Column is able to work well within the 2-8 pH range. What Is The Maximum Pressure That The SunFire C18 Column Can Tolerate? The SunFire C18 Column has been designed to withstand a maximum pressure of 6000 psi (415 Bar).