Thermo Fisher Pipette Products: E1-ClipTip™, Finnpipette™ & ART™ Tips
1188 productsWhether you’re building PCR master mixes, plating ELISA assays, or transferring viscous samples, you need reliable tools that preserve accuracy and reduce fatigue. This collection brings together Thermo Fisher pipettes, pipette controllers, and compatible ClipTip™/ART™ tips—available from Iright with quick quotes and dependable supply—so you can choose confidently and work faster.
-
Core families: E1-ClipTip™ electronic (single, multichannel, adjustable tip spacing), Finnpipette™ manual (single/multi), and S1 pipet fillers.

-
Matching consumables: ClipTip™ interlocking tips and ART™ aerosol-barrier tips in sterile, low-retention, and extended-length options.
-
Practical tools you can use today: a workflow-by-volume selection matrix, mini “playbooks,” and a representative SKU table.
Choose Thermo Fisher Pipettes by Workflow and Volume
You’ll get the most consistent results when the target volume sits near the middle of a pipette’s range and the instrument matches your throughput. Use the matrix below to narrow options by task, then fine-tune by channel count, ergonomics, and required sterility or filtration.
Quick Selection Matrix
Workflow / Task | Typical Range | Best-fit Instrument | Why It Helps | Tip Recommendation |
---|---|---|---|---|
qPCR/PCR master mix | 1–50 µL | E1-ClipTip™ single-channel electronic | Programmable steps (repeat dispense/serial dilute) reduce hand strain, keep timing consistent | ClipTip™ low-retention; sterile for contamination-sensitive work |
96/384-well plating | 5–200 µL | E1-ClipTip™ multichannel or Finnpipette™ F1 multichannel | Even well-to-well delivery; faster plate setup | ClipTip™ filtered tips for PCR; extended length for deep-well |
Tube ↔ plate transfers | 10–1250 µL | E1-ClipTip™ Equalizer (adjustable tip spacing) | Matches tube racks to plate spacing to cut transfer time | ClipTip™ size matched to volume (200/300/1000/1250 µL) |
Cell culture media/serum | 1–100 mL | S1 pipet filler + serological pipets | Rapid, fatigue-free large-volume handling | Serological pipets; hydrophobic filters on controller |
Viscous or volatile samples | 5–1000 µL | E1-ClipTip™ repeat-dispense modes or positive-displacement compatible tools | Minimizes air compression error and drip | Low-retention tips; barrier tips to reduce aerosol carryover |
Practical tips: pre-wet the tip for sub-10 µL volumes; keep the angle consistent (≤20°) on aspiration/dispense; for multichannel work, verify plate alignment and pause briefly after aspiration to stabilize columns.
Pipette Families at a Glance—E1-ClipTip™, Finnpipette™ & S1
Each family targets a different mix of ergonomics, throughput, and programmability. Skim the highlights, then jump to the SKU table when you’re ready to shortlist exact models.
-
E1-ClipTip™ electronic pipettes (single & multichannel): electronic aspiration/dispense with step-based programs, repeat dispense, serial dilution, and protocol storage. The interlocking ClipTip™ interface improves sealing and reduces tip pop-off during plate work.
-
E1-ClipTip™ Equalizer (adjustable tip spacing): slide to match spacing between tubes, gel lanes, and plates to speed up multi-transfer workflows without extra adapters.
-
Finnpipette™ F1 (manual single/multichannel): lightweight, precise mechanical pipettes with low plunger force and color-coded ranges; ideal when power-free, low-maintenance operation is preferred.
-
S1 Pipet Fillers: battery-powered controllers for serological pipets; balanced design for long sessions and quick mode changes for aspirate/dispense.

Pipette Tips & Consumables—ClipTip™ and ART™ Barrier Options
The tip is part of the measurement system. Proper fit and cleanliness directly affect recovery, especially below 20 µL or with sticky samples. Use this section to map tip style to your sensitivity and throughput needs before you finalize models or packaging.
-
ClipTip™ tips: interlocking seal for ClipTip-compatible pipettes; available in 12.5, 20, 50, 200, 300, 1000, and 1250 µL with rack or reload formats. Options include low-retention and extended-length for deep-well access.
-
ART™ barrier tips: aerosol-resistant filter that seals on contact with contaminants—ideal for PCR, qPCR, and workflows where carryover is unacceptable.
-
Sterility & packaging: sterile/non-sterile, hinged racks or reload decks, bulk/case packs to match your space and waste goals.
-
Compatibility reminder: E1-ClipTip models require ClipTip™ sizes (e.g., ClipTip 12.5/200/300/1250), while Finnpipette F1 uses standard compatible tips; for qPCR, barrier tips minimize false positives due to aerosolized amplicons.
Pipetting Playbooks—PCR, ELISA and Viscous-Sample Handling
Once you’ve chosen the instrument, small setup habits protect precision. These short, reusable “playbooks” give you a starting point you can adapt to your SOP and kit instructions.
PCR/qPCR Setup (5–50 µL)
-
Equilibrate reagents on ice; spin down briefly.
-
Pre-wet tips 2–3×; keep aspiration slow and consistent.
-
Use repeat-dispense for master mix aliquots; pause 1–2 s before dispense.
-
Change tips between templates; keep tubes vertical on aspiration.
-
Seal plates promptly; verify wells for bubbles and top up if needed.
ELISA Plate Filling (50–200 µL)
-
Balance plate on a flat, non-vibrating surface.
-
Align multichannel tips to the A-row; seat tips fully with even pressure.
-
Dispense to the sidewall to reduce bubbles; maintain a constant rhythm.
-
Use electronic multichannel for consistent timing across rows.
-
Replace tips between standards/samples to prevent cross-talk.
Viscous/Volatile Samples (e.g., glycerol, solvents)
- Prefer low-retention tips; slow plunger on both strokes.
- Reverse pipetting or electronic multi-dispense reduces trailing.
- For highly volatile solvents, minimize dwell time and keep the tip depth consistent.
- Wipe exterior of tips with lint-free tissue before dispense; avoid rapid ejection that splashes.
Representative Thermo Fisher Pipettes & Tips—Filterable SKU Table
Use these examples to align your short list with ranges and compatible tips; full assortments and colors are available on request. All catalog numbers below correspond to Thermo Scientific product listings.
Product Name | Type | Volume / Channels | Compatible Tip | Sterility | Format | Catalog No. |
---|---|---|---|---|---|---|
E1-ClipTip™ Bluetooth Electronic | Single-channel electronic | 0.5–12.5 µL, 1-channel | ClipTip 12.5 | — | — | 4670000BT |
E1-ClipTip™ Bluetooth Electronic | Multichannel electronic | 0.5–12.5 µL, 8-channel | ClipTip 12.5 | — | — | 4671000BT |
E1-ClipTip™ Equalizer (Adjustable Spacing) | Multichannel electronic | 15–1250 µL, 6-channel | ClipTip 1250 | — | — | 4672090BT |
Finnpipette™ F1 Multichannel | Manual multichannel | 10–100 µL, 12-channel | Standard compatible | — | — | 4661060N |
ClipTip™ Pipette Tips | Interlocking tips | 300 µL | Low-retention, extended-length | Non-sterile | Rack (768) | 94410610 |
ClipTip™ Filtered Tips | Interlocking barrier tips | 1000 µL | Filtered | Sterile | Rack / Reload | 94420713 |
ART™ Barrier Tips, Hinged Rack | Aerosol-resistant tips | 200 µL | Universal fit | Sterile, PCR-ready | Hinged rack (case) | 2069-HR |
S1 Pipet Filler | Pipette controller | For 1–100 mL serological pipets | — | — | White | 9501 |
Pipette FAQs—Selection, ISO 8655 Calibration, Sterility & Compatibility
When you’re close to ordering, a few recurring points help teams align on specs and documentation. Use or adapt the answers below in internal notes or purchase requests.
1. Do I need filtered (barrier) tips for PCR and qPCR?
Yes—ART™ barrier tips add a physical aerosol block that reduces carryover risk when handling templates or amplicons. For routine buffer work, non-filtered tips are fine, but follow your lab’s contamination policy.
2. What’s the difference between ClipTip™ and standard tips?
ClipTip™ uses an interlocking interface to lock and seal the tip until ejection. This improves sealing across channels in plate work and reduces tip pop-off; use ClipTip sizes that match your E1-ClipTip pipette.
3. Can I autoclave my pipette?
For models with autoclave-safe lower parts, you can autoclave the lower assembly (follow the manual for temperature/time). Always perform a leak test and, if required, recalibration checks after sterilization.
4. How often should I calibrate?
Follow your ISO 8655 schedule and local SOP—typically every 6–12 months for general labs, more frequently for regulated workflows. Keep certificates with the instrument ID for audit trails.
5. Which instrument for viscous or volatile samples?
Use electronic modes like reverse/repeat dispense with low-retention tips. For highly challenging liquids, consider positive-displacement solutions to limit expansion/compression effects.
Get Recommendations & Quotes from Iright
If you share your typical workflows, target volumes, channel needs, and sterility requirements, Iright will propose a ready-to-order set: pipette(s), compatible ClipTip™/ART™ tips, and any S1 accessories you might need. Prefer to self-serve? Ask for a CSV shortlist you can import into your purchasing system, or request a quick call to finalize details.