BRAND / VENDOR: BD

BD, 552576, BD OptEIA™ Mouse IgG2a ELISA Set

CATALOG NUMBER: 552576

Preço normal$0.99
/
Frete calculado no checkout.
  • 99 em estoque
  • Inventory no caminho

Este site é protegido por hCaptcha e a Política de privacidade e os Termos de serviço do hCaptcha se aplicam.

Product Description

Reactivity: Mouse (QC Testing)
Application: ELISA (Routinely Tested)
Regulatory Status: RUO
RRID: AB_2868964
Description: Description The OptEIA™ Set for mouse IgG2a contains the components necessary to develop enzyme-linked immunosorbent assays (ELISA) for natural or purified mouse IgG2a in serum, plasma, and cell culture supernatants. Sufficient materials are provided to yield approximately 20 plates of 96-wells if the recommended storage, materials, buffer preparation, and assay procedure are followed as specified in this package. Assay Optimization BD OptEIA™ Sets allow flexible assay design to fit individual laboratory needs. To design an immunoassay with different sensitivity and dynamic range, the following parameters can be varied: Capture, Detection Antibody titers, Incubation time, Incubation temperature, Assay Diluent formulation, Buffer pH, ionic strength, protein concentration, Type of substrate, Washing technique (i.e., number of wash repetitions and soak times).
Preparation And Storage: Preparation And Storage Store unopened reagents at 2-8°C. do not use reagents after expiration date, or if turbidity is evident. Before use, bring all reagents to room temperature (18-25°C). Immediately after use, return to proper storage conditions. Lyophilized standards are stable until expiration date. After reconstitution, immediately aliquot standard stock in polypropylene vials at 50 µl per vial anf freeze at -80°C for up to 6 months. If necessary, store at 2-8°C for up to 8 hours prior to aliquotting/freezing. Do not leave reconstituted standard at room temperature.
Recommended Assay Procedures: Recommended Assay Procedures Recommended buffers, solutions Note: Do not use sodium azide in these preparations. Sodium azide inactivates the horseradish peroxidase enzyme. The BD OptEIA™ Reagent Set B (Cat. No 550534) containing Coating Buffer, Assay Diluent, Substrate Reagents A and B, Stop Solution and 20X Wash Buffer Concentrate is recommended. 1. Coating Buffer - 0.1 M Sodium Carbonate, pH 9.5; 7.13 g NaHCO3, 1.59 g Na2CO3; q.s. to 1.0 L; pH to 9.5 with 10 N NaOH. Freshly prepare or use within 7 days of preparation, stored at 2-8°C. 2. Assay Diluent- PBS* with 10% FBS#, pH 7.0. The BD Pharmingen™ Assay Diluent (Cat. No. 555213) is recommended. *Phosphate-Buffered Saline: 80.0 g NaCl, 11.6 g Na2HPO4, 2.0 g KH2PO4, 2.0 g KCL, q.s. to 10 L; pH to 7.0. #Fetal Bovine Serum: Hyclone Cat. No. SH30088 (heatinactivated) recommended. Freshly prepare or use within 3 days of preparation, with 2-8°C  storage. 3. Wash Buffer - PBS* with 0.05% Tween-20. Freshly prepare or use within 3 days of preparation, stored at 2-8°C. 4. Substrate Solution - Tetramethylbenzidine (TMB) and Hydrogen Peroxide. The BD Pharmingen™ TMB Substrate Reagent Set (Cat. No. 555214) is recommended. 5. Stop Solution - 1 M H3PO4 or 2 N H2SO4 Additional Materials Required 1. 96-well BD Falcon™ ELISA plates (Cat. No. 353279) are recommended 2. Microplate reader capable of measuring absorbance at 450 nm 3. Precision pipettes 4. Graduated cylinder, one liter 5. Deionized or distilled water 6. Wash bottle or automated washer 7. Log-log graph paper or automated data reduction 8. Tubes to prepare standard dilutions 9. Laboratory timer 10. Plate sealers or parafilm Specimen Collection and Handling Specimens should be clear, non-hemolyzed and non-lipemic. Cell culture supernatants: Remove any particulate material by centrifugation and assay immediately or store samples at ≤ -20°C. Avoid repeated freeze-thaw cycles. Serum: Use a serum separator tube and allow samples to clot for30 minutes, then centrifuge for 10 minutes at 1000 x g. Remove serum and assay immediately or store samples at ≤ -20° C. Avoid repeated freeze-thaw cycles. Plasma: Collect plasma using citrate, EDTA, or heparin as anticoagulant. Centrifuge for 10 minutes at 1000 x g within 30 minutes of collection. Assay immediately or store samples at ≤ -20° C. Avoid repeated freeze-thaw cycles. Standards Preparation and Handling 1. Reconstitution: After warming lyophilized standard to room temperature, carefully open vial to avoid loss of material. Reconstitute lyophilized standard with 1.0 mL of deionized water to yield a stock standard. Allow the standard to equilibrate for at least 15 minutes before making dilutions. Vortex gently to mix. 2. Storage/ handling of reconstituted standard: After reconstitution, immediately aliquot standard stock in polypropylene vials at 50 μl per vial and freeze at -80°C  for up to 6 months. If necessary, store at 2-8° C for up to 8 hours prior to aliquotting/freezing. Do not leave reconstituted standard at room temperature. 3. Standards Preparation for Assay: a. Prepare a 200 ng/mL standard from the stock standard. Vortex to mix. (See dilution instructions on Instruction/Analysis Certificate.) b. Add 300 μL Assay Diluent to 6 tubes. Label as 100 ng/mL, 50 ng/mL, 25 ng/mL, 12.5 ng/mL, 6.3 ng/mL, and 3.1 ng/mL. c. Perform serial dilutions by adding 300 μL of each standard to the next tube and vortexing between each transfer. Assay Diluent serves as the zero standard (0 pg/mL). Standardization: This immunoassay is calibrated against purified mouse IgG2a. Detailed Assay Procedure 1. Coat microwells with 100 μL per well of Capture Antibody diluted in Coating Buffer. For recommended antibody coating dilution, see lot-specific Instruction/Analysis Certificate. Seal plate and incubate overnight at 4° C. 2. Aspirate wells and wash 3 times with ≥ 300 μL/well Wash Buffer. After last wash, invert plate and blot on absorbent paper to remove any residual buffer. 3. Block plates with ≥ 200 μL/well Assay Diluent. Incubate at RT for 1 hour. 4. Aspirate/wash as in step 2. 5. Prepare standard and sample dilutions in Assay Diluent. See "Standards Preparation and Handling." 6. Pipette 100 μL of each standard, sample, and control into appropriate wells. Seal plate and incubate for 2 hours at RT. 7. Aspirate/ wash as in step 2, but with 5 total washes. 8. Add 100 μL of Detection Antibody diluted in Assay Diluent to each well. Seal plate and incubate for 1 hour at RT. 9. Aspirate/ wash as in step 2, but with 5 total washes. 10. Add 100 μL of Enzyme Reagent diluted in Assay Diluent to each well. Seal plate and incubate for 30 min at RT. 11. Aspirate/ wash as in step 2, but with 7 total washes. NOTE: In this final wash step, soak wells in wash buffer for 30 seconds to 1 minute for each wash. 12. Add 100 μL of Substrate Solution to each well. Incubate plate (without plate sealer) for 30 minutes at room temperature in the dark. 13. Add 50 μL of Stop Solution to each well. 14. Read absorbance at 450 nm within 30 minutes of stopping reaction. If wavelength correction is available, subtract absorbance at 570 nm from absorbance 450 nm. Assay Procedure Summary 1. Add 100 μL diluted Capture Ab to each well. Incubate overnight at 4°C. 2. Aspirate and wash 3 times. 3. Block plates: 200 μL Assay Diluent to each well. Incubate 1 hr RT 4. Aspirate and wash 3 times. 5. Add 100 μL standard or sample to each well. Incubate 2 hr RT. 6. Aspirate and wash 5 times. 7. Add 100 μL diluted Detection Ab to each well. Incubate 1 hr RT. 8. Aspirate and wash 5 times. 9. Add 100 μL diluted SAv-HRP to each well. Incubate 30 min RT. 10. Aspirate and wash 7 times (with 30 sec to 1 min soaks) 11. Add 100 μL Substrate Solution to each well. Incubate 30 min RT in dark 12. Add 50 μL Stop Solution to each well. Read at 450 nm within 30 min with λ correction 570 nm. Calculation of Results Calculate the mean absorbance for each set of duplicate standards, controls and samples. Subtract the mean zero standard absorbance from each. Plot the standard curve on log-log graph paper, with IgG2a concentration on the x-axis and absorbance on the y-axis. Draw the best fit curve through the standard points. To determine the IgG2a concentration of the unknowns, find the unknown's mean absorbance value on the y-axis and draw a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the x-axis and read the IgG2a concentration. If samples were diluted, multiply the IgG2a concentration by the dilution factor. Computer data reduction may also be employed, utilizing log-log regression analysis. Specificity Cross Reactivity: The following immunoglobulins were tested at ≥ 10 µg/ml for potential cross-reactivity in the BD OptEIA™ mouse IgG2a ELISA Set. No significant cross-reactivities were identified (values ≥ 3.1 ng/ml). Mouse Immunoglobulins: IgG1 (κ), IgG1 (λ), IgG2b (κ), IgG2b (λ), IgG3 (κ), IgG3 (λ), IgM (κ), IgM (λ), IgA (κ), IgA (λ), IgE (κ) Rat Immunoglobulins: IgG1 (κ), IgG1 (λ), IgG2a (κ), IgG2a (λ), IgG2b (κ), IgG2b (λ),IgG2c (κ), IgM (κ), IgM (λ), IgA (κ), IgE (κ) Serum samples from different mouse species (BALB/c, NZB, NZBWF1,and BXSB), immunized or unimmunized, were tested in this assay. Themeasured IgG2a concentrations ranged from 0.16 mg/ml to 5.46 mg/ml. No detectable IgG2a was found in SCID mouse (RAG-/-) serum. Immunoglobulin Allotypes Researchers should be aware that slight differences with the measurements of IgG2a levels may occur across different species and/or allotypes. The BD OptEIA™ mouse IgG2a Set is known to have different affinities for IgG2a from mice of the b allotype as compared with the a allotype. It recognizes a allotype IgG2a approximately 8.1 time better than b allotype IgG2a. Because a purified monoclonal IgG2a antibody of the a allotype is used for the standard in this assay, a conversion factor of 8.1 should be used to quantitate b allotype IgG2a levels. For example, a group of C57BL/6 (b allotype) mouse serum samples were tested using this assay and showed a concentration range of 1.04-7.84 µg/ml, the actual range should be of 8.4-63.5 µg/ml after the conversion. Limitations of the Procedure · Samples that generate absorbance values higher than the standard curve should be diluted with Standard Diluent and re-assayed. · Interference by drug metabolites, soluble receptors, or other binding proteins in specimens has not been thoroughly investigated. The possibility of interference cannot be excluded. · BD OptEIA™ Sets are intended for use as an integral unit. Do not mix reagents from different Set batches. Reagents from other manufacturers are not recommended for use in this Set.

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924