BRAND / VENDOR: Agilent

Agilent, CP7487, J&W CP-Sil 88 for FAME GC Column, 60 m, 0.25 mm, 0.20 µm, 7 inch cage

CATALOG NUMBER: CP7487

Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • 99 en stock
  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

J&W CP-Sil 88 for FAME GC Column, 60 m, 0.25 mm, 0.20 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.

Specifications:
Capillary Tubing: Fused Silica
Film Thickness: 0.2 µm
Format: 7 inch
Inner Diameter (ID): 0.25 mm
Length: 60 m
Phase: CP-Sil 88
Polarity: High Polarity
Temperature Range: 50 °C-225/240 °C
UNSPSC Code: 41115710
USP Designation: G5
With Smart Key: No

**********The following product description is generated by AI and is for reference only. If you have any questions, please contact customer service.**********
The J&W CP-Sil 88 for FAME GC Column, measuring 60 meters in length with a 0.25 mm internal diameter and 0.20 µm film thickness, is engineered for high-resolution analysis of fatty acid methyl esters in complex matrices. This column features a highly polar stationary phase based on cyanosilicone, delivering optimal peak resolution and excellent separation of cis and trans isomers. It is ideally suited for food testing laboratories, nutritional studies, and biodiesel research, allowing accurate determination of fatty acid profiles in edible oils, animal fats, dairy products, and plant materials.

The column’s robust design with a standard 7 inch cage ensures broad compatibility with most gas chromatography systems, including Agilent, Shimadzu, Thermo Fisher, and PerkinElmer instruments, facilitating seamless integration into existing analytical workflows. Its superior performance is recognized in both routine quality control and urgent research applications requiring precise quantitation of fatty acid compositions. For enhanced productivity, it can be paired with Agilent autosamplers and corresponding FID detectors. This solution enables laboratories to meet regulatory standards in food authenticity, labeling, and safety with confidence and efficiency, providing reliable and reproducible results across diverse sample types.

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)