BRAND / VENDOR: Agilent

Agilent, CP7488, J&W CP-Sil 88 for FAME GC Column, 50 m, 0.25 mm, 0.20 µm, 7 inch cage

CATALOG NUMBER: CP7488

Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • 99 en stock
  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

J&W CP-Sil 88 for FAME GC Column, 50 m, 0.25 mm, 0.20 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.

Specifications:
Agency Method: ASTM D2743
Capillary Tubing: Fused Silica
Film Thickness: 0.2 µm
Format: 7 inch
Inner Diameter (ID): 0.25 mm
Length: 50 m
Phase: CP-Sil 88
Polarity: High Polarity
Temperature Range: 50 °C-225/240 °C
UNSPSC Code: 41115710
USP Designation: G5
With Smart Key: No

**********The following product description is generated by AI and is for reference only. If you have any questions, please contact customer service.**********
Designed for optimal performance in fatty acid methyl esters (FAME) analysis, this GC column features a highly polar cyanopropyl polysiloxane stationary phase that delivers outstanding resolution of cis and trans isomers. With a length of 50 meters, an internal diameter of 0.25 mm, and a 0.20 µm film thickness, it efficiently separates complex mixtures according to regulatory standards such as AOAC and EN 14103 for biodiesel quality control, food testing, and nutritional labeling. The robust polyimide-coated fused silica tubing ensures excellent thermal stability and low bleed, supporting reliable operation in both research and routine laboratories. Suitable for the identification and quantification of fatty acids in biological matrices, vegetable oils, animal fats, and processed foods, this column is widely adopted in food safety, environmental, and lipidomics applications. Compatible with a broad range of Agilent and other major GC systems, it facilitates seamless integration and method transfer. The 7 inch cage supports installation on standard autosamplers and ovens, making it a versatile solution for analysts requiring precise fatty acid profiling. For comprehensive workflow needs, consider pairing with Agilent reference standards, sample preparation kits, and FAME-specific calibration mixtures.

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)