BRAND / VENDOR: Agilent

Agilent, CP7511, J&W CP-Al2O3/KCl GC Column, 10 m, 0.32 mm, 5.00 μm, 7 inch cage

CATALOG NUMBER: CP7511

Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • 99 en stock
  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

J&W CP-Al2O3/KCl GC Column, 10 m, 0.32 mm, 5.00 μm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.

Specifications:
Capillary Tubing: Fused: Silica
Film Thickness: 5 µm
Format: 7 inch
GC Column Type: PLOT
Inner Diameter (ID): 0.32 mm
Length: 10 m
Phase: CP-Al2O3/KCl
Temperature Range: -100 °C-200/200 °C
UNSPSC Code: 41115710
With Smart Key: No

**********The following product description is generated by AI and is for reference only. If you have any questions, please contact customer service.**********
The Agilent J&W CP-Al2O3/KCl GC column is a high-performance solution designed for the precise analysis of light hydrocarbons, including C1 to C5 compounds, in complex gas mixtures. Engineered with an alumina-based stationary phase deactivated with potassium chloride, this column offers exceptional selectivity, resolution, and inertness, making it particularly suited for petrochemical, refinery, and natural gas analyses where quantification of trace-level hydrocarbons is critical. With a length of 10 meters, an internal diameter of 0.32 millimeters, and a film thickness of 5.00 micrometers, this configuration delivers rapid separations with minimal sample adsorption and peak tailing, ensuring reliable quantitation even at low detection limits. The 7-inch cage facilitates compatibility with most standard gas chromatographs. This column is ideally matched with Agilent and other major GC systems for both routine quality control and advanced research applications. Recommended use cases include compliance testing, process monitoring, and R&D in energy, chemical, and environmental laboratories. For comprehensive hydrocarbon analysis, this column can be effectively combined with methanizer or FID detectors and is compatible with related alumina PLOT columns for tailored separation strategies.

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)