BRAND / VENDOR: BD

BD, 564696, BD Pharmingen™ MitoStatus TMRE

CATALOG NUMBER: 564696

Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • 99 en stock
  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

Application: Bioimaging, Flow cytometry, Immunofluorescence (Tested During Development)
RRID: AB_2869606
Regulatory Status: RUO
Recommended Assay Procedures: Recommended Assay Procedures Dye Preparation Bring BD Pharmingen™ MitoStatus TMRE dye powder and fresh cell culture-grade Dimethyl Sulfoxide (DMSO; eg, Sigma D2650) to room temperature. Reconstitute TMRE dye powder in DMSO at a stock concentration of 0.2-1 mM. For example, 1 mg of BD Pharmingen™ MitoStatus TMRE can be dissolved in 1.94 mL of DMSO to yield a 1 mM stock solution (MW = 514.96 g/mol). Dye Storage Upon arrival, store the dye powder desiccated and protected from light at ≤ -20°C until use. The dye powder is stable for at least 12 months if stored as indicated. After reconstitution with DMSO, store the stock solution at ≤ -20°C in small aliquots. The stock solution is stable for at least 6 months if stored as indicated. Flow Cytometry Requirements Before staining with this reagent, please confirm that your flow cytometer is capable of exciting the fluorochrome and discriminating the resulting fluorescence. Flow Cytometers (eg, BD FACSCanto™ II, BD LSRFortessa™, BD™ LSR II, or BD Accuri™ C6) equipped with a blue (eg, 488 nm) or yellow-green (eg, 561 nm) laser can be used. TMRE dye fluorescence can be detected with filters commonly used for phycoerythrin (PE) (eg, 575/26 or 582/15 nm). Fluorescence compensation is best achieved using the cell samples of interest. When designing multicolor fluorescent staining panels, please be aware of high fluorescence spillover into the following fluorochromes' detectors: BD Horizon™ PE-CF594, BV605, BV650, or PerCP-Cy™5.5. We recommend titrating the dye and using the lowest concentration that provides adequate resolution of polarized and depolarized cell populations to reduce fluorescence spillover. Procedure BD Pharmingen ™ MitoStatus TMRE labeling of suspended cells for flow cytometric analysis 1. Count cells to determine cell density. Adjust cell density to 1 × 10^6 cells/mL or less in fresh, pre-warmed cell culture media. 2. Stain cells in fresh, pre-warmed cell culture media or desired stain buffer with 20-200 nM BD Pharmingen ™ MitoStatus TMRE in a polypropylene container by adding the stock solution directly to the cells at the desired concentration. a. Note: BD Pharmingen™ MitoStatus TMRE may also be added directly to the culture instead of staining in fresh media. Staining may also be performed in pre-warmed BD Pharmingen™ Stain Buffer (FBS) (Cat. No. 554656) or pre-warmed PBS. PBS may provide increased resolution for some cell types, but can also result in increased background staining. b. Note: TMRE is known to stick to polystyrene. Samples should be stained in polypropylene containers. c. Note: To aid in flow cytometric gating, we recommend using control cells treated with vehicle alone and/or cells treated with a mitochondrial uncoupler, such as FCCP [Carbonyl cyanide 4-(trifluoromethoxy)phenylhydrazone, eg, Sigma Cat. No. C2920]. 3. Incubate samples for 15-30 minutes at 37°C protected from light. 4. Wash cells twice with BD Pharmingen™ Stain Buffer (FBS). 5. Decant the supernatant and gently mix to disrupt the cell pellet. 6. Resuspend the cells in Stain Buffer (FBS). 7. Analyze cells by flow cytometry. Alternatively, counterstain cells with compatible fluorescent dyes or antibodies as desired and then analyze. BD Pharmingen™ MitoStatus TMRE labeling of adherent cells for flow cytometric analysis 1. Adherent cells should be stained in situ at ≤ 70% confluence. Stain cells in fresh, pre-warmed cell culture media or desired stain buffer with 20-200 nM BD Pharmingen ™ MitoStatus TMRE by adding the stock solution directly to the cells at the desired concentration. a. Note: BD Pharmingen™ MitoStatus TMRE may also be added directly to the culture instead of staining in fresh media. Staining may also be performed in pre-warmed BD Pharmingen™ Stain Buffer (FBS) or pre-warmed Dulbecco's PBS (DPBS). DPBS may provide increased resolution for some cell types, but can also result in increased background staining. b. Note: To aid in flow cytometric gating, we recommend using control cells treated with vehicle alone and/or cells treated with a mitochondrial uncoupler, such as FCCP.. 2. Incubate samples for 15-30 minutes at 37°C protected from light. 3. Wash cells twice with BD Pharmingen™ Stain Buffer (FBS). 4. Remove cells from the growth medium. We recommend using BD™ Accutase™ Cell Detachment Solution (Cat. No. 561527). 5. Wash cells twice with BD Pharmingen™ Stain Buffer (FBS) or the equivalent. 6. Decant the supernatant and gently mix to disrupt the cell pellet. 7. Resuspend the cells in Stain Buffer (FBS). 8. Analyze cells by flow cytometry. Alternatively, counterstain cells with compatible fluorescent dyes or antibodies as desired and then analyze. Notes: 1. This dye is not compatible with cellular fixation. 2. Each user should determine the optimal concentrations of reagents, cells, and conditions for the assay of interest. We recommend titrating the reagent in early experiments to obtain optimal results. 3. Cells may be stained in bulk prior to staining with fluorescent antibodies. BD Pharmingen™ MitoStatus TMRE labeling of cells for fluorescent imaging 1. Stain cells in fresh, pre-warmed media with 20-200 nM BD Pharmingen™ MitoStatus TMRE. 2. Incubate samples for 15-30 minutes at 37°C protected from light. 3. Remove the staining solution and replace with pre-warmed DPBS. 4. Analyze cells by fluorescence imaging. Alternatively, counterstain cells with compatible fluorescent dyes or antibodies as desired and then analyze.
Product Notices: Product Notices Since applications vary, each investigator should titrate the reagent to obtain optimal results. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors. Accutase is a registered trademark of Innovative Cell Technologies, Inc. Cy is a trademark of GE Healthcare. Before staining with this reagent, please confirm that your flow cytometer is capable of exciting the fluorochrome and discriminating the resulting fluorescence. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.

Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924