BRAND / VENDOR: Thermo Fisher

Thermo Fisher, 2110XP, Orion™ 2110XP Ammonia Analyzer

CATALOG NUMBER: 2110XP

Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • 99 en stock
  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

2110XP Ammonia Analyzer Reduce operational costs while producing the highest purity steam with the Thermo Scientific™ Orion™ 2110XP Ammonia Analyzer. This analyzer provides continuous, direct and precise measurements for the control and optimization of boiler ammonia levels. Accuracy: ±15% or 30 ppb, whichever is greater
Accuracy (Temperature): ±0.5°C
Accuracy (mV): ± (0.5 mV + 0.1%)
Alarm Output: 3
Amperage: 5A
Analog Outputs: 2, Galvanically Isolated
Calibration: Double Known Addition
Case Material: Valox 364
Certifications/Compliance: CE, CSA, UL, FCC Class A limits
Channel 1: Ammonia
Channel 2: Optional ph/ORP or Conductivity
Channels: 1
Communication Details: Modbus with Additional Module
Current Loops: 2
Description: 2110XP Ammonia Analyzer
Dimensions (L x W x H): 11 x 17 x 26 in. (27 x 45 x 65cm)
Display Type: Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
Enclosure Rating: Waterproof; IP66; NEMA 4X
Flow Rate: 40mL/min.
Frequency: 0 to 60 Hz
Height (English): 26 in.
Height (Metric): 65 cm
Includes: 2110XP ammonia analyzer with Ammonia electrode, reference electrode (100056), ATC probe (2100TP),ammonia calibration standards kit, CD user guide and options kit
Inlet Pressure: 8 to 100psig
Inputs: 85-132; 170-264 VAC
Keypad Type: Membrane
Length (English): 11 in.
Length (Metric): 27 cm
Max. Relative Humidity: 5 to 95%, non-condensing
Measurement Ranges: 0 to 10ppm
Mounting Options: Wall mount
Outputs: 0 to 20 mA; 4 to 20 mA
Range (mV): ±1999.9m
Relay Details: 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
Resolution (Temperature): 0.1°C
Resolution (mV): 0.1mV
Response Time: 95% within 2 minutes of injecting a standard solution
Sample Inlet: 1/4 in. NPTF tube fitting
Sample Streams: 1
Sample Temperature: 5 to 45°C
Voltage: 85/132 VAC, 170/264 VAC
Width (English): 17 in.
Width (Metric): 45 cm
Temperature (Metric) Operating: 5°C to 35°C
Type: Ammonia Analyzer
Unit Size: Each

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.