2111XP Sodium Analyzer With Grab Sampler Meet the demanding needs of high-purity water measurements and high-acid cation exchange applications with the Thermo Scientific™ Orion™ 2111XP Sodium Analyzer. This system offers unmatched reliability in analyzing critical sample streams throughout the power/steam generation and industrial water industry. It is an all-in-one system from one of the most trusted names in sodium monitoring. Accuracy: ±5% or 0.1 ppb, whichever is greater
Accuracy (Temperature): ±0.5°C
Accuracy (mV): ± (0.5 mV + 0.1%)
Alarm Output: 3
Amperage: 5A
Analog Outputs: 2, Galvanically Isolated
Calibration: Double Known Addition
Case Material: Valox 364
Certifications/Compliance: CE, CSA, UL, FCC Class A limits
Channel 1: Sodium
Channel 2: Optional ph/ORP or Conductivity
Channels: 1
Communication Details: Modbus with Additional Module
Current Loops: 2
Description: 2111XP Sodium Analyzer With Grab Sampler
Detection Limits: 0.1 ppb
Dimensions (L x W x H): 11 x 17 x 26 in. (27 x 45 x 65 cm)
Display Type: Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
Enclosure Rating: Waterproof; IP66; NEMA 4X
Flow Rate: 40 mL/min.
Frequency: 0 to 60 Hz
Height (English): 26 in.
Height (Metric): 65 cm
Includes: 2111XP sodium analyzer with grab sampler, sodium electrode, reference electrode, ATC probe, sodium calibration standards kits, CD user guide and options kit
Inlet Pressure: 8 to 100 psig
Keypad Type: Membrane
Length (English): 11 in.
Length (Metric): 27 cm
Max. Relative Humidity: 5 to 95%, non-condensing
Measurement Ranges: 0 to 10 ppm
Mounting Options: Wall mount
Outputs: 0 to 20 mA; 4 to 20 mA
Relay Details: 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
Response Time: 95% within 2 minutes of injecting a standard solution
Sample Inlet: 1/4 in. NPTF tube fitting
Sample Streams: 1
Sample Temperature: 5°C to 45°C
Voltage: 85/132 VAC, 170/264 VAC
Width (English): 17 in.
Width (Metric): 45 cm
Temperature (Metric) Operating: 5°C to 35°C
Type: Na Analyzer, Grab Sampler
Unit Size: Each

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)