BRAND / VENDOR: Thermo Fisher

Thermo Fisher, 2120XP, Orion™ 2120XP Calcium Hardness Analyzer

CATALOG NUMBER: 2120XP

Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • 99 en stock
  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

2120XP Calcium Hardness Analyzer Limit the costly effects of improper water purification using the Thermo Scientific™ Orion™ 2120XP Calcium Hardness Analyzer. This analyzer detects calcium as a major component of hardness in real time, providing accurate and reliable results. Accuracy: ±10% or 10 ppb, whichever is greater
Accuracy (Temperature): ±0.5°C
Accuracy (mV): ± (0.5 mV + 0.1%)
Alarm Output: 3
Amperage: 5A
Analog Outputs: 2, Galvanically Isolated
Calibration: Double Known Addition
Case Material: Valox 364
Certifications/Compliance: CE, CSA, UL, FCC Class A limits
Channel 1: Calcium
Channel 2: Optional ph/ORP or Conductivity
Channels: 1
Communication Details: Modbus with Additional Module
Current Loops: 2
Description: 2120XP Calcium Hardness Analyzer
Dimensions (L x W x H): 11 x 17 x 26 in. (27 x 45 x 65 cm)
Display Type: Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
Enclosure Rating: Enclosure not included
Flow Rate: 40 mL/min.
Frequency: 0 to 60 Hz
Height (English): 26 in.
Height (Metric): 65 cm
Includes: 2120XP calcium analyzer with calcium electrode, reference electrode, ATC probe, calcium calibration standards kit, CD user guide and options kit
Inlet Pressure: 8 to 100 psig
Keypad Type: Membrane
Length (English): 11 in.
Length (Metric): 27 cm
Max. Relative Humidity: 5 to 95%, non-condensing
Measurement Ranges: 0 to 10ppm
Mounting Options: Wall mount
Outputs: 0 to 20 mA; 4 to 20 mA
Relay Details: 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
Response Time: 95% within 2 minutes of injecting a standard solution
Sample Flow Rate: 40 mL/min nominal set by pressure regulator
Sample Inlet: 1/4 in. NPTF tube fitting
Sample Streams: 1
Temperature (English) Operating: 41°F to 95°F
Voltage: 85/132 VAC, 170/264 VAC
Width (English): 17 in.
Width (Metric): 45 cm
Temperature (Metric) Operating: 5°C to 35°C
Type: Calcium Hardness Analyzer
Unit Size: Each

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)