Product Description
7500 Fast Real-Time PCR System, tower, QST The 7500 Real-Time PCR System is a powerful platform for labs requiring superior performance and maximum dye versatility. It is a sophisticated platform for users who require extended capabilities and maximum versatility. The 3rd generation platform features an innovative optical system that enhances sensitivity and lets you access a broader range of fluorophores. The variable excitation capability allows greater sensitivity for longer wavelength (red) dyes.
• Powerful, five-color platform is calibrated for the broadest range of dyes available: FAM/SYBR Green I, VIC/JOE, NED/TAMRA/Cy3, ROX/Texas Red, and Cy5 dyes
• Specialized optical system enables easy and accurate calibration to new dyes without requiring the addition of new filter sets
• Advanced multi-componenting algorithm minimizes spectral crosstalk, superior for multiplexing
• User-friendly software includes plate set-up wizards, multi-plate data viewing capabilities, and advanced analysis tools to make data processing simple and straightforward7500 Software v2.
xNow the easy-to-use StepOne software is available for both the 7500 and 7500 Fast systems with the 7500 Software v2.
x upgrade. The 7500 Software v2.
x incorporates your favorite StepOne Software features, such as multiple plate setup wizards, calculators for standard curve dilution and master mix recipes, QC flags, data filters, and email notification when a run is finished. The 7500 Software v2.
x also includes an enhanced Gene Expression Study package and has a variety of new melting curve protocol options, including multiple peak detection, step and hold temperature control, and customizable ramp rates.
Gene Expression Study package accommodates large studies better than any other instrument software package
• Import an unlimited number of Comparative CT (relative quantitation) files to one study
• Group samples and view data both by technical replicate group and biological replicate group
• Use any gene(s) as an endogenous control, including averaging multiple controls together
• Enter known efficiency values to be factored into the RQ results21 CFR Part 11 Module availableThe SDS v1.
4 21CFRp11 Module is a powerful tool for assisting with 21CFRp11 compliance, while still offering the flexibility of user-customizable configuration settings.
• Individual user log-ins can be added for up to four user groups, each group with designated permission settings
• User-customizable permission settings include fourteen system activities, e-signature authority designation, and additional security settings to give you maximum control over your compliance efforts
• Audit trails can be enabled or disabled depending on your traceability needs
• A selection of e-signatures is available to ease e-signatures into your workflowSupports Many ApplicationsApplications include gene expression analysis, pathogen quantitation, SNP genotyping, isothermal and +⁄– assays utilizing internal positive controls. To facilitate many of these applications, we provide preformulated, ready-to-use, quality-tested, TaqMan assays for use with the 7500 system. Now you can reduce your assay optimization efforts.
Upgrade to High-Speed Thermal CyclingAn optional upgrade to a the 7500 Fast System is available. This 7500 Fast System uses our master mix formulations and enables you to shorten your real-time PCR runs to as little as 30 minutes.
Calibrated Dye: SYBR™ Green I, ROX™, NED™, TAMRA™, JOE™, Texas Red™, Cy5™, VIC™, FAM™, Cy3™
Data Acquisition: Collects data for all 5 filters for all wells regardless of plate setup
Dimensions: 34 cm (W) x 49 cm (H) x 45 cm (D) (13.
39 in. x 19.
29 in. x 17.
72 in.)
Dynamic Range: 9 Logs of Linear Dynamic Range
Electrical Requirements: 950 W
External Computer: Minitower
For Use With (Equipment): 7500 Fast System
Format: 96-well Plate
High-throughput Compatibility: High-throughput Compatible, Multiplexing
Optics: Tungsten-halogen Lamp, Five-Emission Filters and CCD Camera, Five-Excitation Filters
Passive Reference Dye: ROX (Separate Tube), ROX (Pre-mixed)
Precision: Can distinguish between 5000 and 10000 Template Copies with 99.
7% Confidence
Quantity: 1 each
Reaction Speed: Fast, Standard
Reaction Volume Range: 10 to 30 μL
Sample Ramp Rate: Fast Mode: ± 2.
2°C⁄s, Standard mode: ± 1.
6°C⁄s
Sensitivity: Down to 1 Copy of Human RNAse P gene
Software Compatibility: Primer Express Software, System Software
Temperature Range (Metric): 4 to 100°C
Thermal Accuracy: Within 0.
5°C (35° to 95°C) of Setpoint/Display Temp. (3 min. after start)
Thermal Cycling System: Peltier-based System
Thermal Uniformity: Within 1.
0°C (30 s after Clock Start)
Throughput: Manual Loading of four-five 96-well Plates per 8-hr day (Real Time throughput)
Voltage: 120 V
Weight: 75 lb.
Unit Size: Each
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmtaion.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924