Orion Versa Star Pro benchtop meter with pH/mV module, conductivity/TDS/salinity/resistivity module and stand, Versa Star Pro meter, VSTAR-PH pH module, VSTAR-CND conductivity module, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate Get high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter. Meet your most challenging applications for pH, mV, ORP, conductivity, total dissolved solids (TDS), salinity, resistivity and temperature. Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules. View pH and conductivity simultaneously or view each channel separately. Log up to 2000 data point sets with time/date stamp and easily transfer logs to a printer or computer. AC Adapter: Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
Accuracy (Conductivity): 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Accuracy (Resistivity): 0.5% of reading ±1 digit
Accuracy (Salinity): 0.5% of reading ±1 digit
Accuracy (TDS): 0.5% of reading ±1 digit
Accuracy (mV): ±0.2 mV or ±0.05% of reading whichever is greater
Accuracy (pH): ±0.002
Alarm Output: Set point alarm, high/low limit alarm, calibration due alarm
Backlight Option: Yes
Calibration: pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op
Calibration Points: 1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Points (Conductivity): Up to 6
Calibration Points (pH): 1 to 6
Cell Constant: 0.001 to 199.9cm-1
Certifications/Compliance: CE, TUV 3-1, FCC Class A
Data Management Details: Transfer single, range or all data points to printer or computer
Data Points: 2000 with Date and Time Stamp
Description: Orion Versa Star Pro benchtop meter with pH/mV module, conductivity/TDS/salinity/resistivity module and stand
Dimensions (L x W x H): 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
Includes: Versa Star Pro meter, VSTAR-PH pH module, VSTAR-CND conductivity module, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Inputs: BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe)
Isopotential Point: 7.000pH (adjustable)
Keypad: Numeric with menu-specific function keys and dual purpose scroll/shortcut keys
Languages: English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
Log Function Type: Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with
Memory: Non-volatile memory preserves data log, calibration log and meter settings
Methods: 10 per channel
Outputs: USB (2), RS232
Power Rating: DC input: 9VDC, 1A
Power Supply: Universal AC adapter (included)
Product Type: Meter
Range (ORP): ±2000.0 mV
Range (Relative mV): ±2000.0 mV
Relative Humidity Range: 5 to 85 %, non-condensing
Resolution (Conductivity): 0.001 μS minimum, auto ranging up to 4 significant digits
Resolution (Resistivity): 1 ohm or 0.1 meg-ohm, auto ranging
Resolution (Salinity): 0.01 psu or 0.01 ppt minimum, auto ranging
Resolution (TDS): 0.001 ppm minimum, auto ranging up to 4 significant digits
Resolution (mV): 0.1mV
Salinity Measurement Modes: Practical salinity (psu) or natural sea water (ppt)
Stability: Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
TDS Factor Range: Linear (0.02 to 9.99)
Temperature Accuracy: ±0.1°C
Temperature Compensation: Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (English) Operating: 41°F to 113°F (ambient)
Temperature (Metric) Operating: 5°C to 45°C (ambient)
Temperature (Metric) Reference: 5, 10, 15, 20, 25°C
Temperature Probe Calibration: 1 point temperature offset calibration
Temperature Range (English): 22.0°F to 221.0° F
Temperature Resolution: 0.1°C, 0.1°F
Temperature Selection: Manual or automatic with ATC temperature probe
Warranty: 3 year meter and module warranty
Weight (English): 2.5 lb., modules add 0.5 lb. each
Weight (Metric): 1.2 kg, modules add 0.2 kg each
Channels: 4 (Customizable with modules)
Display Type: Color graphic LCD with user-customizable options
IP Rating: IP54
Measurement Modes: pH, mV, Relative mV, TDS, ORP with Temperature, Salinity, Conductivity, Resistivity with Temperature
Range (Conductivity): 0.001 μS/cm to 3000 mS/cm
Range (Resistivity): 2 ohm to 100.0 meg-ohm
Range (Salinity): 0.06 to 80.00 psu, 0.05 to 42.00 ppt
Range (TDS): 0.001 ppm to 200.0 ppt
Range (mV): ±2000.0 mV
Range (pH): -2 to 20
Resolution (pH): 0.1/0.01/0.001
Temperature Range (Metric): -5.0°C to +105.0°C
Unit Size: Each
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmtaion.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924