BRAND / VENDOR: Thermo Fisher
Thermo Fisher, VSTAR92, Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
CATALOG NUMBER: VSTAR92
- 99 en stock
- En rupture de stock, expédition prochainement
No reviews
Orion Versa Star Pro Benchtop Meter with VSTAR-ISE pH/mV/ISE/Temperature Module; VSTAR-CND Conductivity/TDS/Resistivity/Salinity/Temperature Module; VSTAR-RD RDO/DO/Temperature Module Kit, Versa Star Pro meter, VSTAR-ISE pH/ISE module, VSTAR-CND conductivity module, VSTAR-RD RDO/DO module, 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD Orion DuraProbe 4-cell (K=0.475) conductivity sensor, 083005MD Orion polarographic dissolved oxygen sensor, 096019 Orion Star stirrer probe, 810199 ROSS pH buffer and solution kit, 011007 Orion 1413µS conductivity standard, 080513 DO maintenance kit, BOD adapter/funnel/stirrer, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate Get high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter. Meet your most challenging applications for pH, ion concentration, conductivity, dissolved oxygen and temperature. Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules. Log up to 2000 data point sets with time/date stamp and easily transfer logs via USB or RS232 to a printer or computer. Select systems with one or two pH/ISE modules. AC Adapter: Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
Accuracy (Barometer): ±6 mmHg
Accuracy (Conductivity): 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Accuracy (ISE): ±0.2 mV or ±0.05% of reading whichever is greater
Accuracy (Polarographic DO): ±0.2 mg/L or ±2% of reading, whichever is greater
Accuracy (RDO): ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L
Accuracy (Resistivity): 0.5% of reading ±1 digit
Accuracy (Salinity): 0.5% of reading ±1 digit
Accuracy (TDS): 0.5% of reading ±1 digit
Accuracy (mV): ±0.2 mV or ±0.05% of reading whichever is greater
Accuracy (pH): ±0.002
Advanced ISE Functions: Timed endpoint, linear point to point, non-linear selectable auto-blank, low concentration range sta
Alarm Output: Set point alarm, high/low limit alarm, calibration due alarm
Backlight Option: Yes
Barometric Pressure Correction: 400 to 850mmHg, automatic using built-in barometer or manual entry
Calibration: pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
Calibration Modes: Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Calibration Points: 1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Points (Conductivity): Up to 6
Calibration Points (ISE): 1 to 6
Calibration Points (pH): 1 to 6
Cell Constant: 0.001 to 199.9cm-1
Certifications/Compliance: CE, TUV 3-1, FCC Class A
Data Management Details: Transfer single, range or all data points to printer or computer
Data Points: 2000 with Date and Time Stamp
Description: Orion Versa Star Pro Benchtop Meter with VSTAR-ISE pH/mV/ISE/Temperature Module; VSTAR-CND Conductivity/TDS/Resistivity/Salinity/Temperature Module; VSTAR-RD RDO/DO/Temperature Module Kit
Dimensions (L x W x H): 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
Includes: Versa Star Pro meter, VSTAR-ISE pH/ISE module, VSTAR-CND conductivity module, VSTAR-RD RDO/DO module, 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD Orion DuraProbe 4-cell (K=0.475) conductivity sensor, 083005MD Orion polarographic dissolved oxygen sensor, 096019 Orion Star stirrer probe, 810199 ROSS pH buffer and solution kit, 011007 Orion 1413μS conductivity standard, 080513 DO maintenance kit, BOD adapter/funnel/stirrer, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Inputs: BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
Isopotential Point: 7.000pH (adjustable), 1.000 ISE (adjustable)
Keypad: Numeric with menu-specific function keys and dual purpose scroll/shortcut keys
Languages: English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
Log Function Type: Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with
Memory: Non-volatile memory preserves data log, calibration log and meter settings
Methods: 10 per channel with password protection
Model: Orion Versa Star Pro 90 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Benchtop Meter
Outputs: USB (2), RS232
Percent Saturation Range (Polarographic DO): 0.0 to 600.0% saturation
Percent Saturation Relative Accuracy (RDO): ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation
Percent Saturation Resolution (Polarographic DO): 0.1, 1% saturation
Percent Saturation Range (RDO): 0.0 to 500.0% saturation
Percent Saturation Resolution (RDO): 0.1, 1% saturation
Percent Saturation Relative Accuracy (Polarographic DO): ±2 % saturation or ±2% of reading whichever is greater
Power Rating: DC input: 9VDC, 1A
Power Supply: Universal AC adapter (included)
Pressure Range: 400 to 850mmHg
Pressure Resolution: 0.1mmHg
Product Type: Meter, pH/ISE/mV/Temp. Module
Range (ISE): 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none
Range (ORP): ±2000.0 mV
Range (Polarographic DO): 0.00 to 90.00mg/L
Range (RDO): 0.00 to 50.00mg/L
Range (Relative mV): ±2000.0 mV
Relative Humidity Range: 5 to 85%, non-condensing
Resolution (Conductivity): 0.001 μS minimum, auto ranging up to 4 significant digits
Resolution (Polarographic DO): 0.01, 0.1mg/L
Resolution (RDO): 0.01, 0.1mg/L
Resolution (Resistivity): 1 ohm or 0.1 meg-ohm, auto ranging
Resolution (Salinity): 0.01 psu or 0.01 ppt minimum, auto ranging
Resolution (TDS): 0.001 ppm minimum, auto ranging up to 4 significant digits
Resolution (mV): 0.1mV
Salinity Factor: 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity
Salinity Measurement Modes: Practical salinity (psu) or natural sea water (ppt)
Stability: Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
TDS Factor Range: Linear (0.02 to 9.99)
Temperature Accuracy: ±0.1°C
Temperature Compensation: Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (English) Operating: 41°F to 113°F (ambient)
Temperature (Metric) Operating: 5°C to 45°C (ambient)
Temperature (Metric) Reference: 5°, 10°, 15°, 20°, 25°C
Temperature Probe Calibration: 1 point temperature offset calibration
Temperature Range (English): 22.0°F to 221.0° F
Temperature Resolution: 0.1°C, 0.1°F
Temperature Selection: Manual or automatic with ATC temperature probe
Warranty: 3 year meter and module warranty
Weight (English): 2.5 lb., modules add 0.5 lb. each
Weight (Metric): 1.2 kg, modules add 0.2 kg each
Channels: 4 (Customizable with modules)
Display Type: Color graphic LCD with user-customizable options
IP Rating: IP54
Measurement Modes: pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature, TDS, Conductivity, Salinity
Percent Saturation Range Polarographic DO: 0.0 to 600.0% saturation
Range (Conductivity): 0.001 μS/cm to 3000 mS/cm
Range (Resistivity): 2 ohm to 100.0 meg-ohm
Range (Salinity): 0.06 to 80.00 psu, 0.05 to 42.00 ppt
Range (TDS): 0.001 ppm to 200.0 ppt
Range (mV): ±2000.0 mV
Range (pH): -2 to 20
Resolution (ISE): 0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (pH): 0.1/0.01/0.001
Temperature Range (Metric): -5.0°C to +105.0°C
Unit Size: Each
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmtaion.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924