Iright
BRAND / VENDOR: BD

BD, 558522, BD™ Cytometric Bead Array (CBA) 30 Plex Bead Mixture

CATALOG NUMBER: 558522
Preço normal$0.99
/
Frete calculado no checkout.
  • ddddd

    99 xxxxxx

  • Inventory no caminho

Este site é protegido por hCaptcha e a Política de privacidade e os Termos de serviço do hCaptcha se aplicam.

Product Description

Application: Array (Routinely Tested)
RRID: AB_2869214
Regulatory Status: RUO
Preparation And Storage: Preparation And Storage Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.
Recommended Assay Procedures: Recommended Assay Procedures 1. Vortex the BD CBA 30 Plex Bead Mixture to bring beads into suspension. 2. Transfer 25 µl of the BD CBA 30 Plex Bead Mixture to the appropriate sample well or tube. 3. Add 175 µl of Wash Buffer (from one of the BD CBA Master Buffer Kits) to the bead sample. More Wash Buffer (275 µl) may be needed for samples in tubes. 4. Proceed with analysis on a BD flow cytometer that has been setup according to the instrument setup procedure included with the BD CBA Master Buffer Kits and export the FCS2.0 file for the 30 plex bead mixture. 5. Analyze the 30 plex bead mixture data file using the FCAP Array software clustering tool. If the FCAP Array software fails to identify 30 bead clusters, repeat steps 4 and 5 after repeating the instrument setup procedure. If the FCAP Array software is unable to identify 30 bead clusters from the repeat sample, instrument service may be required. Note: Do not store the diluted beads. Prepare a new bead sample for each test. The BD CBA 30 Plex Bead Mixture can be included as an additional sample when performing the instrument setup procedure included with the BD CBA Master Buffer Kits. A sample file generated for the bead mixture can be analyzed to demonstrate that the FCAP Array Software identifies 30 bead populations by using the Clustering Test Tool in the FCAP Array Software. For more information on the use of the Clustering Test Tool in the FCAP Array Software, refer to Chapter 8 in the FCAP Array Software User's Guide .
Product Notices: Product Notices Source of all serum proteins is from USDA inspected abattoirs located in the United States. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924