BRAND / VENDOR: Waters

Waters, 186000418, XTerra MS C18 Column, 125Å, 3.5 µm, 3 mm X 100 mm, 1/pk

CATALOG NUMBER: 186000418

Обычная цена$0.99
/
/ru/policies/shipping-policy '>Стоимость доставки рассчитывается при оформлении заказа.
  • В наличии, готов к отправке
  • Под заказ, отправка скоро

Этот веб-сайт защищается hCaptcha. Применяются Политика конфиденциальности и Условия использования hCaptcha.

Product Description

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 12 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Bonding Technology: MS C18
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 3.5 µm
Endfitting Type: Waters
Pore Size: 125 Å
Format: Column
Surface Area: 175
System: HPLC
USP Classification: L1
Inner Diameter: 3 mm
Length: 100 mm
Carbon Load: 16 %
UNSPSC: 41115709
Brand: XTerra
Product Type: Columns
Units per Package: 1 pk

Additional Information
XTerra MS C18 Column, 125Å, 3.5 µm, 3 mm X 100 mm, 1/pk The general-purpose, hybrid-based, reversed-phase C18 columns known as XTerra MS C18 columns are made to work with mass spectrometry applications. Comparing these first-generation columns to a silica-based column, they offer improved pH stability. The XTerra MS C18 Column has large peak capacities, sharp peak shapes, and high sensitivity. It is suited for Mass Spectrometry (MS) applications. Thanks to the tri-functional bonding chemistry of the XTerra particles, the XTerra MS C18 Column has one of the longest column lifetimes over a wide pH range (1–12), especially when compared to conventional silica-based columns. Along with the column's capacity to deliver maximum throughput with great resolution and little column bleed, these features are highlighted. The analytical column is a reversed-phase C18 hybrid column designed to function with a wide range of mass spectrometry applications. The first-generation XTerra MS C18 Column can provide improved pH stability as compared to a silica-based column. The XTerra MS C18 Column, like all other lab equipment made by Waters, is constructed using ultrapure reagents, guaranteeing that the hybrid particle's chemical makeup and purity are under control. The production process is carried out within strict tolerances and is thoroughly checked and controlled at every stage. To guarantee that you only receive the best laboratory equipment, each column is likewise thoroughly checked. Include the XTerra MS C18 Column in your lab's inventory. Guards, vials, and elution plates are a few more products that are compatible with the XTerra MS C18 Column and may be obtained on our website. On our website, you can shop for lab equipment and get in touch with us if you have any inquiries. In one of our several offices throughout the world, you can speak with a member of our staff about your inquiries and worries. You may also want to review Ostro Protein Precipitation & Phospholipid Removal Plate, 25 mg, 1/pk ; Ostro sample preparation products offer a cutting-edge method for phospholipid removal from plasma and serum. The technique, which uses a straightforward protocol and requires little to no method development, can be swiftly put into use to improve the workflow in your laboratory. Ostro enables more sensitive analysis, greater sample throughput, and decreased instrument downtime by providing cleaner, more repeatable extracts than competing phospholipid devices or procedures.

FAQ
What Pressure Range And pH Range Can The XTerra MS C18 Column Handle? The XTerra MS C18 Column has a pH range of 1 to 12, and its maximum pressure is 6000 psi (or 415 Bar).