Thermo Fisher Flasks for Cell Culture: T-Flasks, Erlenmeyer & Spinner
208 productsWhether you are passaging adherent lines or scaling a suspension process, Thermo Fisher flasks give you a consistent, sterile environment with surfaces and geometries tuned for cell health. This collection page helps you quickly choose among T-flasks, Erlenmeyer shake flasks, and spinner flasks, then drill into specs that matter in regulated labs. As an authorized distributor, Iright supplies a wide range of Thermo Fisher (Thermo Scientific™/Nunc™/Nalgene™) flasks and can bundle accessories, documentation, and technical guidance. Thermo Scientific Nunc flasks feature the Nunclon™ Delta adherent surface; Nalgene shake flasks cover PETG/PC options with vented or solid caps.
Quick Filters – Find the Right Flask by Type, Material, Cap & Volume
To narrow choices fast, start with your culture mode and sterility requirements, then refine by material and volume. These facets map to the most common lab constraints and let you make a defensible pick without wading through every SKU.
Suggested facets (use as on-page filters):
-
Use case: Adherent / Suspension / Media prep & storage
-
Flask type: T-flask / Erlenmeyer / Spinner
-
Material: PETG / PC / PPCO / Glass
-
Volume (nominal): 125 mL · 250 mL · 500 mL · 1 L · 2 L · 3 L · 5 L
-
Cap style: Vented filter (0.2 μm) / Solid (plug-seal or screw)
-
Surface: Nunclon Delta / Untreated / Low-binding (e.g., Spheroid workflows)
-
Sterility: Sterile / Gamma-irradiated / Non-sterile
-
Geometry: Baffled vs. plain bottom(shake flasks)
-
Compliance: USP Class VI / non-pyrogenic / RNase-/DNase-free
Compare Flask Types – T-Flasks vs. Erlenmeyer vs. Spinner (Table)
Use this table to match flask classes to your biology and scale. Focus on surface chemistry for adherent lines, oxygen transfer for suspension culture, and cleaning/assembly burden for repeated use or disposables.
Dimension | T-Flask (Nunc EasYFlask) | Erlenmeyer (Nalgene PETG/PC) | Spinner Flask |
---|---|---|---|
Typical use | Adherent culture, expansion, banking | Suspension culture, media mixing, scale-up on shakers | Higher-density suspension, microcarrier, long runs |
Surface | Nunclon™ Delta for strong attachment & plating consistency | Untreated (suspension) | Untreated; agitation via paddle/impeller |
Oxygen transfer | Low–moderate (gas exchange via cap) | Moderate–high; baffles increase OTR | High (active mixing), requires control of shear |
Cap options | Filter (vented) or solid | Vented 0.2 μm or solid | Ports, sidearms, vented caps (system-dependent) |
Sterility | Pre-sterilized options | Pre-sterilized PETG/PC, gamma-irradiated | Sterile disposables or sterilizable glass |
Working volume | Area-based (T25–T225) | ~20–30% of nominal (e.g., 500 mL flask → 100–150 mL) | Per design; often run at 30–70% of nominal |
Reuse | Single-use plastics; some glass variants exist | Single-use PETG/PC or reusable PC/Glass | Disposable or reusable systems |
Strengths | Reproducible attachment; easy microscopy | Efficient gas exchange; shaker-friendly; scalable to 5 L | High cell density; closed-system options |
Watch-outs | Limited OTR; overconfluence risk | Choose baffled vs. plain bottom; shaker speed limits | Shear stress; assembly & handling complexity |
Nunclon Delta is the standard adherent surface used across Nunc flasks and is lot-tested for growth performance; baffled PETG/PC Erlenmeyer options provide higher mixing and oxygen transfer on orbital shakers.
Key Specifications – Surface, Sterility, Vented Caps, Materials & Compliance
Choosing the right specification avoids variability, contamination, and compliance gaps. Start from the downstream assay’s tolerance for shear and additives, then select surfaces, caps, and polymers you can qualify.
-
Surface treatment (adherent workflows): Nunclon™ Delta improves initial attachment and plating efficiency and is validated across multiple cell types. Choose untreated surfaces for suspension culture or spheroid workflows.
-
Cap & gas exchange: Vented filter caps (typically 0.2 μm) support CO₂ exchange and reduce contamination risk; solid/plug-seal caps are suited to storage or transport. Confirm cap thread (e.g., 45-430) for interchangeability.
-
Geometry & mixing: Baffled bottoms increase turbulence and OTR in Erlenmeyer flasks; plain bottoms are gentler for shear-sensitive cells. Spinner flasks deliver active mixing, but impeller speed must balance oxygenation and shear.
-
Material selection:
-
PETG: Clear, robust, gamma-compatible; common in sterile single-use shake flasks.
-
PC/PPCO/PMP: Higher heat resistance options exist in reusable lines; check autoclave compatibility.
-
-
Sterility & cleanliness: Look for gamma-irradiated sterile stock and documentation of non-pyrogenic, RNase-/DNase-free status as needed for sensitive work.
-
Compliance: Maintain Certificates of Analysis/Compliance (CoA/CoC), USP Class VI materials data, and lot traceability for audits.
Best Practices – Seeding, Working Volume, Shaking/OTR & Aseptic Handling
Translate specs into day-to-day practice so your cultures behave predictably. The following pointers reflect common lab standards for these flask classes.
-
T-flasks (adherent): Select Nunclon Delta for routine adherent lines. Seed evenly to avoid edge effects; monitor confluence and split at biologically relevant endpoints. Use filter caps in CO₂ incubators to balance gas exchange and contamination control.
-
Erlenmeyer (suspension/scale-up): Keep working volume at ~20–30% of nominal to maintain headspace and mixing efficiency; prefer baffled versions when oxygen transfer is a bottleneck. Verify shaker RPM and throw to stay within manufacturer limits and avoid cap leakage.
-
Large-scale shake flasks (up to 5 L): PETG single-use options with vented caps reduce prep time and contamination risk while supporting transient expression or early bioprocess development.

-
Spinner flasks: Start at lower impeller speeds and titrate up while tracking viability; use closed-system or sterile connectors where available to limit open handling.
-
Aseptic handling: Double-check sterile packaging, cap integrity, and port closures; log lot numbers and retain CoA/CoC in your batch record.
Featured Products – Popular Thermo Fisher & Nunc SKUs for Fast Purchasing
Below are representative, commonly requested SKUs to help you move quickly from selection to order.
Brand/Line | Product | Type | Material | Size/Area | Notes / Typical Use | Catalog # |
---|---|---|---|---|---|---|
Nunc™ EasYFlask™ | Cell culture–treated T-flask | T-flask | Polystyrene | T-75 (75 cm²) | Nunclon Delta surface for adherent cells | 156499 |
Nunc™ EasYFlask™ | Cell culture–treated T-flask | T-flask | Polystyrene | T-25 (25 cm²) | Adherent culture starter size | 156367 |
Nunc™ EasYFlask™ | Cell culture–treated T-flask | T-flask | Polystyrene | T-175 (175 cm²) | Scale-out for adherent lines | 159910 |
Nunc™ EasYFlask™ | Cell culture–treated T-flask | T-flask | Polystyrene | T-225 (225 cm²) | Max surface area in T-series | 159934 |
Nalgene™ | Single-Use PETG Erlenmeyer (vented) | Erlenmeyer | PETG | 500 mL | Sterile, shaker ready | 4116-0500 |
Nalgene™ | Single-Use PETG Erlenmeyer (solid) | Erlenmeyer | PETG | 2 L | Sterile, mixing/media prep | 4113-2000 |
Nalgene™ | Polycarbonate Erlenmeyer, baffled | Erlenmeyer | PC | 1 L | Reusable; increased OTR via baffles | 4110-1000 |
Nalgene™ | Polycarbonate Erlenmeyer, baffled | Erlenmeyer | PC | 500 mL | Reusable lab workhorse | 4110-0500 |
Nalgene™ | 5-L PETG shake flask (vented) | Erlenmeyer | PETG | 5 L | Large-scale suspension / transient expression | 4115-5001 |
Compatibility & Accessories – Shaker Clamps, Filter Caps, Connectors & Media
After you select a flask, consider the accessories that protect yield and keep your runs compliant. Position these as cross-links or add-to-cart bundles so buyers don’t forget essentials at checkout.
-
Shaker accessories: Platform clamps/holders sized to each flask; verify RPM and orbit spec with baffled PETG/PC flasks.
-
Cap & closure options: Spare vented 0.2 μm caps and solid/plug-seal caps in the correct thread (e.g., 38-430, 45-430, 70 mm) for your chosen flask family.
-
Tubing/connectors: Sterile connectors, GL45 adapters, sampling needles for semi-closed handling.
-
Upstream consumables: Gibco™ media, supplements, filters, pipettes; microcarriers for spinner use where applicable.
-
Documentation: CoA/CoC, material statements, irradiation certificates—link them near the add-to-cart to reduce procurement friction.
FAQs – T25/T75 Basics, Nunclon Delta vs. Untreated, PETG vs. PC, 0.2 μm Caps
Use concise answers that remove hesitation and reduce pre-sales questions. Keep each answer under 80–100 words for scannability.
Q1. When should I choose T-flasks over Erlenmeyer?
Use T-flasks for adherent workflows that benefit from Nunclon Delta attachment and simple microscopy. Switch to Erlenmeyer when you want suspension growth, higher oxygen transfer, and shaker compatibility.
Q2. Nunclon Delta vs. untreated—what changes in practice?
Nunclon Delta increases initial attachment and plating consistency for many adherent lines; you can seed lower and split predictably. Untreated surfaces are preferred for suspension or low-attachment needs.
Q3. Do baffled flasks always perform better?
Baffles typically raise mixing and oxygen transfer, which helps fast-growing suspensions. However, shear-sensitive cells may prefer plain bottoms—optimize RPM/throw and test viability before committing.
Q4. What’s the role of 0.2 μm vented caps?
They maintain gas exchange while reducing contamination risk in CO₂ incubators and on shakers. Match thread size to the flask family and keep spares to avoid downtime.
Q5. PETG vs. PC—how do I decide?
PETG single-use flasks are clear, robust, and ready-to-use for sterile workflows. PC offers durable, reusable options; check heat resistance and autoclave guidance for your model.
Talk to Iright – Request Quotes, Certificates (CoA/CoC) & Technical Guidance
If you need help mapping a process—e.g., seeding densities from T-75 to 2 L shake flasks or choosing cap styles for CO₂ vs. shaker runs—Iright can recommend a validated bundle. Tell us your cell type, target volume, and incubator/shaker specs; we’ll prepare a quote, provide certificates, and coordinate delivery.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make any payment before confirmation.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924