Product Description
Mass Spectrometry standards kit for system assessment. 10 Component Kit 1. Set-up Solution QP PPG 10002.5 ng/uL, Triacetyl-B-cyclodextrin 5.0 ng/ul, Verapamil 100.0 pg/ul, Leucine Enkaphalin 1.0 ng/ul, Ammonium Acetate 0.31 mg/ml in 1:1 Aceto/water 15mL brown Nalgene 2. 1 x 10 ml ESI Resolution: PPG 2000 Solution 1.0 ug/ul Ammonium Acetate 10.2 mg/ml in Acetonitrile/Water (1:1 V/V) 15mL clear Nalgene 3. 3. 1 x 10ml ESI Mass Measurement Accuracy: PEG 1000 Solution 100.0 ng/ul Ammonium Acetate 0.17 mg/ml in Acetonitrile/Water (1:1 V/V) 15mL clear Nalgene 4. 1 x 5mg ESI Sensitivity Reserpine: 5mg solid resperpine in 4mL amber screw Top vial 5. 1 X 10mg ESI Sensitvitiy Raffinose: 10mg solid Raffinose in 4mL Screw Top Vial 6.1 x 10 mg Ion Sabre APCI Sensitivity: 10mg solid 7-alphahydroxyprogesterone in 4 ml Amber Screw Top Vial 7. 1 x 50 mg ESI Sensitivity Chloramphenicol: 50 mg solid Chloramphenicol Solid in 8mL amber screw Top Vial 8. 1 X 10mL API Calibration Solution: Sodium Iodide 2ug/uL, Cesium Iodide 50ng/uL in IPA/Water (1:1V/V) in 15 mL Clear Nalgene Bottle 9. 1 x 5mg ESCi Switch/Sensitivity: 5mg solid Sulfadimethoxine Solid in 4mL amber screw top vial 10. X 15mL API Set Up Solution Reserpine 2ng/uL, PPG 1000 25ug/uL, Triacetyl-B-cyclodextran 50ng/uL in Acetonitrile/4mM Ammonium Acetate (50:50) in 15mL Clear Nalgene Bottle 11. Solution Prep Document 715000966 Certificate of Analysis
Specifications
Separation Mode: Reversed Phase
Detection Method: MS
Formulation: Liquid, Solid
Storage Condition: Room Temperature
System Type: MS
Shelf Life: 12 Months
Shipping Condition: Ambient
Type: Qualification
UNSPSC: 41116107
Application: System Performance
Product Type: Standards
Units per Package: 1 pk
Additional Information
TQD/Q-Premier/XE/Q-Micro Qualification Standards Test Kit The TQD/Q-Premier/XE/Q-Micro Qualification Standards Test Kit is part of the MS Triple Quadrupole Standards collection series. The kit contains compounds that enable scientists to assess the performance or to calibrate the triple quadrupole detector. Using this lab equipment and its mass scale calibration, resolution and sensitivity testing in different ionization modes can be conducted. The TQD/Q-Premier/XE/Q-Micro Qualification Standards Test Kit will ensure optimal MS performance and make you confident with the results you get from your assay. The components of this Standard Tests Kit include: Set-up Solution QP PPG 10002.5 ng/uL, Triacetyl-B-cyclodextrin 5.0 ng/ul, Verapamil 100.0 pg/ul, Leucine Enkephalin 1.0 ng/ul, Ammonium Acetate 0.31 mg/ml in 1:1 Aceto/water 15mL brown Nalgene 1 x 10 ml ESI Resolution: PPG 2000 Solution 1.0 ug/ul Ammonium Acetate 10.2 mg/ml in Acetonitrile/Water (1:1 V/V) 15mL clear 3. 1 x 10ml ESI Mass Measurement Accuracy: PEG 1000 Solution 100.0 ng/ul Ammonium Acetate 0.17 mg/ml in Acetonitrile/Water (1:1 V/V) 15mL clear Nalgene 1 x 5mg ESI Sensitivity Reserpine: 5mg solid reserpine in 4mL amber screw Top vial 1 X 10mg ESI Sensitivity Raffinose: 10mg solid Raffinose in 4mL Screw Top Vial 1 x 10 mg Ion Sabre APCI Sensitivity: 10mg solid 7-alpha hydroxyprogesterone in 4 ml Amber Screw Top Vial 1 x 50 mg ESI Sensitivity Chloramphenicol: 50 mg solid Chloramphenicol Solid in 8mL amber screw Top Vial 1 X 10mL API Calibration Solution: Sodium Iodide 2ug/uL, Cesium Iodide 50 ng/uL in IPA/Water (1:1V/V) in 15 mL Clear Nalgene Bottle 1 x 5mg ESCi Switch/Sensitivity: 5mg solid Sulfadimethoxine Solid in 4mL amber screw-top vial X 15mL API Set Up Solution Reserpine 2ng/uL, PPG 1000 25 ug/uL, Triacetyl-B-cyclodextrin 50ng/uL in Acetonitrile/4mM Ammonium Acetate (50:50) in 15mL Clear Nalgene Bottle The TQD/Q-Premier/XE/Q-Micro Qualification Standards Test Kit is shipped with a Certificate of Analysis and Solution Prep Document 715000966. You can shop for lab equipment from our website or browning through our brochure. You may also be interested in the IonHance Difluoracetic Acid Mobile Phase Kit , which includes two 1.1 mL IonHance DFA vials and two 1000 mL LDPE mobile phase bottles to maintain the high levels of purity IonHance has to offer. Both the PFA and LDPE (low-density polyethylene) containers are rigorously QC tested to ensure less than 100 ppb levels of sodium and potassium to achieve exquisitely high-quality mass spectra.
FAQ
What Does The Term HPLC Stand For? High-performance liquid chromatography (HPLC) is an analytical technique renowned for its ability to effectively separate, identify, and quantify components within a mixture. As the predominant technique utilized in laboratories worldwide, HPLC plays a pivotal role in a diverse range of applications. Its versatility allows scientists and researchers to unravel the complexities of mixtures, enabling accurate analysis and providing valuable insights across numerous scientific disciplines.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make payment before confirmation.
3. Minimum order value of $1,000 USD required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924