Iright
BRAND / VENDOR: Waters

Waters, 176001124, ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 3/pk

CATALOG NUMBER: 176001124
Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • ddddd

    99 xxxxxx

  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 1 pH
pH Range Max: 8 pH
Temperature Limits: 45 C
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 1.8 µm
Endfitting Type: Parker-style
Pore Size: 100 Å
Format: Column
Surface Area: 230
System: UPLC, UHPLC
Particle Technology: HSS
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 50 mm
Carbon Load: 15 %
eCord: Yes
UNSPSC: 41115709
Brand: ACQUITY UPLC
Product Type: Columns
Units per Package: 3 pk

Additional Information
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 3/pk ACQUITY UPLC HSS C18 chemistry is a high-performance general-purpose C18 bonded phase that offers superior peak shape for bases, greater retention (as compared to ACQUITY UPLC BEH C18 columns), and extraordinarily long column lifetimes at low pH. ACQUITY HSS C18 columns are completely scalable and can be used in HPLC separations. Reduce the possibility of technique variation as a result of irregularities in chromatographic media batches or columns. Because it was designed to give reliable and reproducible results, you can count on the ACQUITY UPLC HSS C18 SB Column to deliver consistent results year after year. ACQUITY HSS C18 SB columns are completely scalable and can be used in HPLC separations. Furthermore, the lab equipment is employed for low pH separations of complicated combinations of basic and non-basic substances. To gain alternative selectivity for molecules impacted by silanophilic interactions, use the ACQUITY UPLC HSS C18 SB Column's unique non-end-capped, low-coverage silica-based C18 chemistry. The lab equipment has a characteristic increased silanol activity as a result of secondary interactions with residual silanols, resulting in greater retention of basic chemicals. This arises as a result of low ligand density and ionic repulsion, which reduces non-basic analyte retention. The unique mix of retention properties of the ACQUITY UPLC HSS C18 SB Column makes it a powerful method development tool for imparting changes in Selectivity for Bases (SB) while producing outstanding peak shape. The packing materials for the ACQUITY UPLC HSS C18 SB Column are designed specifically for use with the ACQUITY UPLC System. They are also manufactured in a cGMP-certified, ISO 9001-certified facility using ultra-pure reagents. Each batch of packing material is chromatographically tested with acidic, basic, and neutral analytes to assure superb, repeatable performance, and the results are held within constrained specification ranges. The ACQUITY UPLC HSS C18 SB Column mentioned is one of numerous options. You can shop for lab equipment on our website, search for all goods that are compatible with the current offering, or find different variations of the same listing. You might be interested in AutoPurification System Standard as well. The portfolio of Quality Control Reference Materials is a one-of-a-kind collection of standards and mixtures. These tools enable the user to analyze and benchmark their chromatography equipment prior to performing essential material analysis. The portfolio's goods have all been uniquely created based on the knowledge of Waters experts. Thionin, Thioflavin, and Crystal Violet are among the three components in the AutoPurification Dye Standard.

FAQ
Why Are Cations Found Only in Mass Spectrometry Data? When employing mass spectrometry to measure the mass of charged particles, only ions can be identified because neutral molecules cannot be seen.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924