Iright
BRAND / VENDOR: Waters

Waters, 186003608, XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk

CATALOG NUMBER: 186003608
Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • ddddd

    99 xxxxxx

  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 12 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Silanol Activity: Low
Molecular Weight Range Min: 1000
Molecular Weight Range Max: 15000
Particle Shape: Spherical
Particle Size: 3.5 µm
Endfitting Type: Waters
Pore Size: 300 Å
QC Tested: Peptide
Format: Column
Surface Area: 185
System: HPLC
Particle Technology: BEH
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 100 mm
Carbon Load: 18 %
UNSPSC: 41115709
Application: Peptide
Brand: XBridge
Product Type: Columns
Units per Package: 1 pk

Additional Information
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk With low pH stability and extremely little column bleed, the XBridge Peptide BEH C18 Column allows you to analyze samples for proteomics over a broad pH range. The wide-pore (300) tri-functionally bound BEH particle used in the lab apparatus can also be used for protein characterization and peptide synthesis. The XBridge BEH300 C18 Peptide Separation Technology (PST) columns have been QC tested and optimized for peptide separations. To benefit from the Protein Separation Technology of the analytical column, which incorporates BEH technology and uses synthetic particles to deliver the best quality and consistent performance, add the XBridge Peptide BEH C18 Column to your collection of lab supplies. A cGMP, ISO 9002 accredited plant produced the packing materials for the XBridge Peptide BEH C18 columns using an ultra-pure reagent to produce good peak shape, high efficiency, and exceptional stability. Each batch of XBridge Peptide BEH C18 Column material undergoes a peptide separation; the results are held to precise specification ranges. This is done to achieve high, reproducible peptide separation performance. Each column is tested, and a Performance Test Chromatogram, as well as a Certificate of Acceptance, are included in the package with each column. The XBridge Peptide BEH C18 Column underwent quality control verification using a peptide map to ensure the stability of peptide separation procedures. This is accomplished by utilizing established, state-of-the-art bonding procedures for the C18 ligand, which provide reproducible outcomes for a variety of samples utilized in proteomics, protein characterization, and peptide synthesis. You may depend on the analytical column's consistency as a result, getting consistent separations of synthetic peptides and protein digests from batch to batch. Particle structure and bonding chemistry are guaranteed to be stable from pH 1 to 12 and at high temperatures, thanks to the fabrication procedures used for the lab equipment. By looking through our website or the booklet, you can find a full range of Waters products and shop for lab equipment to make sure all of your lab requirements are satisfied. You should also take a look at Cytochrome C Digestion Standard , which was created by breaking down Bovine Heart Cytochrome C (Uniprot # P62894) with sequencing-grade trypsin. According to tight quality control standards that are attested to on the certificate of analysis that is supplied, each batch of the digestion standard is created. Applications for protein digestion standards range from evaluating and benchmarking HPLC and UPLC columns to assessing the performance of mass spectrometry and chromatography equipment.

FAQ
How Does Resolution Function in Chromatography? Because resolution depends on peak width and retention time, both of which are essential components of the chromatographic process, resolution can be used to enhance separations.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924