Waters, 186005294, ACQUITY UPLC CSH C18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pk

CATALOG NUMBER: 186005294

Prix régulier$0.99
/
Frais d'expédition calculés lors du passage à la caisse.
  • 99 en stock
  • En rupture de stock, expédition prochainement

Ce site est protégé par hCaptcha, et la Politique de confidentialité et les Conditions de service de hCaptcha s’appliquent.

Product Description

ACQUITY CSH C18 columns were designed to provide alternate selectivity compared to other reversed-phase UPLC columns. These ultra-efficient columns overcome peak shape asymmetry and poor loading capacity for basic compounds, column bleed, and rapid mobile-phase re-equilibration.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 1 pH
pH Range Max: 11 pH
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 1.7 µm
Endfitting Type: Parker-style
Pore Size: 130 Å
Format: Column
Surface Area: 185
System: UPLC, UHPLC
Particle Technology: CSH
USP Classification: L1
Inner Diameter: 1 mm
Length: 150 mm
Carbon Load: 15 %
eCord: Yes
UNSPSC: 41115709
Brand: ACQUITY UPLC
Product Type: Columns
Units per Package: 1 pk

Additional Information
ACQUITY UPLC CSH C18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pk The ACQUITY UPLC CSH C18 Column offers a larger range of selectivity than Waters' other ACQUITY brands, the ACQUITY UPLC BEH and XBridge. The ACQUITY UPLC CSH C18 Column provides a wide range of selectivities without sacrificing critical performance characteristics such as peak shape for basic chemicals, low column bleed, and seamless transferability between different particle sizes and column formats. Waters designed the ACQUITY UPLC CSH C18 Column in response to feedback gathered at several customer forums. When compared to other reversed-phase UPLC columns, the ACQUITY UPLC CSH C18 Column was developed to provide alternate selectivity. Peak shape asymmetry, inadequate loading capacity for basic chemicals, column bleed, and rapid mobile-phase re-equilibration are all eliminated by these ultra-efficient columns. The Charged Surface Hybrid (CSH) Technology, which is the next generation of particle technology, is the driving force behind the ACQUITY UPLC CSH columns. The basic mechanism behind the lab equipment is Waters' Charged Surface Hybrid (CSH) Technology. Method development is faster and easier with the ACQUITY UPLC CSH C18 Column because CSH Technology provides Trifluoroacetic acid (TFA) peak shape performance without the use of TFA. Though the use of Trifluoroacetic Acid results in crisp peak morphologies for basic chemicals, it is an ion-pairing agent that is difficult to remove from the ACQUITY phase after it has been exposed to a Liquid Chromatography column. With MS-friendly mobile phase additives like formic acid, the lab equipment, on the other hand, can give increased peak shape performance. As formic acid does not react with an ion-pairing agent, this leads to a faster and more straightforward technique development. You may also want to invest in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The vial is made using inert glass so that you can store your analytes, knowing that there will be no interference with the results.

FAQ
What Is The pH Range Offered By The ACQUITY UPLC CSH C18 Column? The ACQUITY UPLC CSH C18 Column listed here is able to function well across the 1-11 pH range. What Is The Maximum Pressure That The ACQUITY UPLC CSH C18 Column Can Take? This particular ACQUITY UPLC CSH C18 Column can work with high pressures, with the maximum being 18000 psi (1240 Bar).