Iright
BRAND / VENDOR: Waters

Waters, 186004689, ACQUITY UPLC HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 150 mm, 1/pk

CATALOG NUMBER: 186004689
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

ACQUITY UPLC HSS C18 SB columns are used for low pH separations that contain complex mixtures of basic and non-basic compounds. ACQUITY HSS C18 SB columns give you alternative analyte selectivity compared to most modern, high coverage, fully endcapped C18 stationary phases. ACQUITY HSS C18 SB columns are fully scalable and transferable to HPLC separations.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Temperature Limits: 45 C
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: No
Bonding Technology: C18 SB
Silanol Activity: Medium
Particle Shape: Spherical
Particle Size: 1.8 µm
Endfitting Type: Parker-style
Pore Size: 100 Å
Format: Column
Surface Area: 230
System: UPLC, UHPLC
Particle Technology: HSS
USP Classification: L1
Inner Diameter: 3 mm
Length: 150 mm
Carbon Load: 8.5 %
eCord: Yes
UNSPSC: 41115709
Brand: ACQUITY UPLC
Product Type: Columns
Units per Package: 1 pk

Additional Information
ACQUITY UPLC HSS C18 SB Column, 100Å, 1.8 µm, 3 mm X 150 mm, 1/pk For low pH separations containing complicated combinations of basic and non-basic chemicals, ACQUITY UPLC HSS C18 SB columns are employed. Compared to the majority of contemporary, high coverage, completely end-capped C18 stationary phases, ACQUITY HSS C18 SB columns offer alternate analyte selectivity. Fully scalable and transferrable to HPLC separations are the ACQUITY HSS C18 SB columns. Reduce the likelihood of technique variation brought on by inconsistent batches of chromatographic medium or columns. This is why you can count on the ACQUITY UPLC HSS C18 SB Column to offer reliable results year after year because it was designed to produce predictable and reproducible results. Utilize the distinct non-end-capped, low-coverage silica-based C18 chemistry of the ACQUITY UPLC HSS C18 SB Column to achieve alternative selectivity for compounds affected by silanophilic interactions. The lab apparatus has a specific increased silanol activity as a result of secondary interactions with leftover silanols, which increases the retention of fundamental chemicals. This happens as ionic repulsion, and poor ligand density reduces non-basic analyte retention. The unique mix of retention properties found in the ACQUITY UPLC HSS C18 SB Column makes it a powerful method development tool capable of delivering modifications in Selectivity for Bases (SB) while providing excellent peak shape. The packaging materials for the ACQUITY UPLC HSS C18 SB Column were created exclusively for the ACQUITY UPLC System. Additionally, they are made with ultra-pure reagents in a facility that is ISO 9001 and cGMP certified. To ensure exceptional, repeatable performance, each batch of the packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to narrow specification ranges. To shop for lab equipment , view all products that are compatible with the present selection, or discover different iterations of the same item, browse our website. We recommend reviewing ACQUITY UPLC HSS C18 SB VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk ; For low pH separations containing complicated combinations of basic and non-basic chemicals, ACQUITY UPLC HSS C18 SB columns are employed. Compared to the majority of contemporary, high-coverage, completely end-capped C18 stationary phases, ACQUITY HSS C18 SB columns offer alternate analyte selectivity. Fully scalable and transferrable to HPLC separations are the ACQUITY HSS C18 SB columns. By immediately connecting to the ACQUITY UPLC column's intake, the VanGuard pre-column decreases the volume of additional columns and reduces leaking by doing away with superfluous connections.

FAQ
Why Do Cations Only Appear in Data from Mass Spectrometry? Only ions can be recognized when measuring the mass of charged particles using mass spectrometry since neutral molecules are invisible.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924