Thermo Fisher Proteins & Peptides: Reagents, Kits & Standards
1406 productsWelcome! This curated collection brings together high-performing Thermo Fisher Scientific™ reagents and tools for protein and peptide workflows—spanning extraction, quantitation, LC-MS prep, purification, labeling, detection, controls, and peptide synthesis. As an authorized distributor, Iright can supply a wide range of Thermo Fisher products with flexible quotes and fast delivery to fit your lab’s needs.
Extraction & Stabilization (Cell Lysis, Inhibitors & Buffers)
Effective proteomics starts with clean, intact protein extracts. Here you’ll find lysis buffers for hard-to-lyse samples and inhibitor cocktails that preserve phosphorylation and prevent proteolysis, so downstream quantitation and MS stay reproducible. Choose EDTA-free options when metal-dependent steps (e.g., IMAC) are ahead in your workflow.

Popular picks (examples):
-
RIPA Lysis & Extraction Buffer, 100 mL — 89900.
-
Halt™ Protease & Phosphatase Inhibitor Cocktail (100X), 1 mL — 78440; 24×100 µL — 78442.
-
Halt™ Protease Inhibitor Cocktail (100X), EDTA-free, 1 mL — 87785; standard, 1 mL — 87786.
- Bond-Breaker™ TCEP Solution, Neutral pH, 5 mL — 77720.
Protein Quantitation (Assay Kits & Standards)
Accurate protein concentration underpins consistent digestion, equal loading, and trustworthy quantitation. Thermo Scientific™ BCA, Micro BCA, Coomassie/Bradford, and Rapid Gold chemistries cover broad dynamic ranges and diverse sample chemistries—including detergent-rich lysates.

Go-to solutions:
-
Pierce™ BCA Protein Assay Kit — 23225.
-
Micro BCA Protein Assay Kit — 23235.
-
Coomassie Plus (Bradford) Protein Assay Kit — 23236.
- Rapid Gold BCA (standard format A53227 or Dilution-Free A55860).
- BSA standards, 2 mg/mL ampules — 23209.
Digestion & Sample Prep for LC-MS
Enzyme choice and clean-up define coverage and sensitivity. Use MS-grade proteases for reproducible cleavage, then desalt and remove surfactants with spin columns to protect your LC-MS and boost IDs. The products below are proven, Orbitrap-friendly workhorses.
Representative SKUs
Product | What it’s for | Catalog No. | Format |
---|---|---|---|
Pierce™ Trypsin Protease, MS-Grade | Gold-standard proteolysis | 90305 | 1×100 µg |
Lys-C Protease, MS-Grade | Complementary/seq. digestion | 90307 | 100 µg |
Trypsin/Lys-C Protease Mix, MS-Grade | Faster, robust digestion | A40007 | 20 µg |
Pierce™ C18 Spin Columns / Tips | Peptide desalting & cleanup | 89870 / 84850 | 25 columns / 96 tips |
Zeba™ Spin Desalting Columns, 7K MWCO | Rapid buffer exchange | 89882 | 25 columns |
Pierce™ Detergent Removal Spin Columns | Remove surfactants pre-MS | 87777 | 25 columns |
Purification & Affinity (His-Tag & Antibody Tools)
Affinity capture improves purity, yield, and confidence in downstream assays. Nickel or cobalt IMAC resins enrich His-tag proteins, while Protein A/G magnetic beads streamline IPs and antibody purification on magnets or robots.
Representative SKUs
Product | Use case | Catalog No. | Format |
---|---|---|---|
HisPur™ Ni-NTA Resin | His-tag protein purification | 88221 | 10 mL |
HisPur™ Cobalt Resin | Higher selectivity vs. Ni-NTA | 89965 | 100 mL |
Pierce™ Protein A/G Magnetic Beads | Broad IgG binding & IP | 88803 | 5 mL |
Pierce™ Protein A Magnetic Beads | Mouse/human IgG focus | 88845 | 1 mL |
Pierce™ Protein G Magnetic Beads | Rabbit/mouse IgG variants | 88848 | 5 mL |
Labeling & Crosslinking (Amine-Reactive Dyes & Crosslinkers)
From antibody biotinylation to distance-constrained crosslinking MS, high-purity reagents ensure specific, stable modifications. Select PEGylated biotin for solubility, NHS esters for primary amines, and cleavable crosslinkers when MS identification demands it.
Representative SKUs
Product | Use case | Catalog No. | Format |
---|---|---|---|
Alexa Fluor™ 488 NHS Ester | Fluorescent labeling of amines | A20000 | 1 mg |
EZ-Link™ NHS-PEG₄-Biotin | Water-soluble biotinylation | 21330 | 25 mg |
EDC (Carbodiimide) | Zero-length crosslinking | 22980 | 5×200 mg |
BS³ (Bis[sulfosuccinimidyl] suberate) | Water-soluble, non-cleavable | 21580 | 1 g |
DSS (Disuccinimidyl suberate) | Membrane-permeable crosslinker | 21655 | 50 mg |
DSSO (MS-cleavable) | XL-MS workflows | A33545 | 5 mg |
Detection for WB/ELISA (Substrates, Membranes & Secondaries)
Reliable detection tightens your limit of detection and dynamic range. Choose ECL substrates matched to abundance, PVDF for strong protein binding, and validated HRP secondaries for clean blots and ELISAs.
Representative SKUs
Product | Application | Catalog No. | Format |
---|---|---|---|
SuperSignal™ West Pico PLUS | Routine WB ECL | 34580 | 500 mL |
SuperSignal™ West Femto | Ultra-sensitive WB ECL | 34095 | 100 mL |
1-Step™ Ultra TMB-ELISA Substrate | Colorimetric ELISA | 34029 | 1 L |
Pierce™ PVDF Transfer Membrane, 0.45 µm | Western blot membrane | 88518 | 1 roll |
Goat anti-Mouse IgG (H+L), HRP | WB/ELISA secondary | 31430 | 1 vial |
Goat anti-Rabbit IgG (H+L), HRP | WB/ELISA secondary | 31460 | 1 vial |
Standards & Controls (MW Markers & System Suitability)
Standards help you compare across runs and instruments. Pair BSA standards for assay calibration with molecular-weight ladders for gel validation, and add PRTC peptides to monitor LC-MS performance over time.
-
PageRuler™ Plus Prestained Protein Ladder (10–250 kDa) — 26619.
-
Pierce™ Unstained Protein MW Marker — 26610.
-
Pierce™ BSA Standards, 2 mg/mL — 23209.
- Pierce™ PRTC Peptide Mixture — 88321.
Peptide Synthesis Essentials (Reagents, Resins & Building Blocks)
For solid-phase peptide synthesis (SPPS), reliable coupling reagents and high-purity Fmoc-amino acids maintain sequence fidelity and yield. Thermo Scientific™ Chemicals (Acros/Alfa Aesar) provides widely used couplers and resins compatible with standard Fmoc strategies.
Representative SKUs
Product | Role in SPPS | Catalog No. | Format |
---|---|---|---|
HBTU, ≥99% | Carbodiimide-free coupling | 401091 | 25 g (example size) |
HATU, ≥97% | Fast, efficient coupler | 365310250 | 25 g |
N-Fmoc-Glycine | Fmoc building block | AB21050 | 50 g |
Fmoc-L-Lysine·HCl | Protected Lys derivative | H59696.06 | 5 g |
2-Chloro-1,3-dimethylimidazolium BF₄ | Activator (CDI alt.) | H54316.06 | 5 g |
Storage & Handling (Quick Guidance)
Proper storage preserves activity and performance. Many inhibitors are shipped cold and stored at 4 °C; ECL substrates and enzymes often require refrigeration; fluorescent dyes and NHS esters are typically kept desiccated at −20 °C, protected from light. Always follow each product’s datasheet for exact conditions.
Application Matrix (Choose-by-Need)
Your goal | Typical sample | Start here | Then consider |
---|---|---|---|
Preserve PTMs during lysis | Cells/tissue lysates | Halt™ Protease & Phosphatase (78440/78442) | RIPA (89900), EDTA-free Halt (87785) |
Accurate concentration | Detergent-rich lysates | BCA (23225) or Rapid Gold BCA (A53227/A55860) | BSA standards (23209) |
Maximize IDs by LC-MS | Purified proteins | Trypsin (90305) ± Lys-C (90307) | C18 cleanup (89870), Zeba (89882) |
Purify His-tag proteins | E. coli lysate | HisPur Ni-NTA (88221) | Cobalt resin (89965) for selectivity |
Immunoprecipitation | Cell lysate | Protein A/G Mag Beads (88803) | Protein A (88845) or G (88848) by species/subclass |
Biotinylate or fluorescent-tag | Antibodies/proteins | NHS-PEG₄-Biotin (21330) or Alexa Fluor 488 NHS (A20000) | EDC/BS³/DSS for crosslinking |
Sensitive detection | Western blots | West Pico PLUS (34580) | West Femto (34095) for very low abundance |
FAQs
Q1. Are Pierce™, Invitrogen™, and Thermo Scientific™ products compatible across workflows?
Yes—these Thermo Fisher brands are designed to interoperate across extraction, quantitation, LC-MS, immunoassays, and imaging. Match chemistries (e.g., EDTA-free with IMAC; MS-grade reagents for LC-MS) for best results.
Q2. Which ECL should I choose for Western blot?
Use West Pico PLUS for most targets; switch to West Femto for very low-abundance proteins. Pair with PVDF membranes and optimized blocking to minimize background.
Q3. When should I pick cobalt over nickel for His-tag purification?
Cobalt generally gives higher purity with slightly lower capacity—use when selectivity matters most or contaminants persist after Ni-NTA.
Q4. Do I need detergent removal before LC-MS?
Yes, typical ionic and nonionic detergents suppress ionization. Use Detergent Removal Spin Columns or C18 cleanup prior to injection.
Q5. What’s the advantage of DSSO vs. DSS/BS³?
DSSO is MS-cleavable, simplifying identification of crosslinked peptides; DSS/BS³ are non-cleavable workhorses for structural mapping and stabilization.
Contact for a Quote
Need a tailored quote, bulk packaging, or cross-workflow guidance? Contact Iright to source any Thermo Fisher™ Proteins & Peptides product above—including alternatives, sizes, and regional lead times. We’ll help you select, bundle, and deliver exactly what your experiments require.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make any payment before confirmation.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924