Iright
BRAND / VENDOR: Biolegend

Biolegend, 165621, StarBright UltraViolet 740 anti-mouse CD38 Antibody, VO31

CATALOG NUMBER: 165621
السعر العادي$0.99
/
  • In stock, ready to ship

  • الطلب مؤجل، سيتم الشحن قريباً

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

This StarBright conjugate is available for purchase as part of a multicolor flow cytometry panel. To order, add compatible products to your shopping cart, or use our Panel Selector tool to build your ideal panel. For ordering assistance or to request a sample, contact your local field representative . This product is also available for direct purchase within a StarBright Basic Panel , which combines a minimal set of pre-selected compatible reagents. CD38, also known as T10, is a 45 kD type II transmembrane glycoprotein. It is an ADP-ribosyl hydrolase expressed at variable levels on hematopoietic cells and in some non-hematopoietic tissues (such as brain, muscle, and kidney). By functioning as both a cyclase and a hydrolase, CD38 mediates lymphocyte activation, adhesion, and the metabolism of cADPR and NAADP. CD31 is thought to be a ligand of CD38.
VO31
Verified Reactivity: Mouse
Antibody Type: Monoclonal
Host Species: Rat
Immunogen: Mouse CD38 transfected cells
Formulation: Phosphate-buffered saline, containing 0.09% sodium azide, 0.05% Tween 20, 0.1% PEG 3350, 0.1% Pluronic F68, and 1% BSA (origin USA)
Preparation: The antibody was purified by affinity chromatography and conjugated with StarBright UltraViolet 740 under optimal conditions.
Concentration: 0.6 mg/mL (the concentration relates to the dye component of the conjugate)
Storage & Handling: The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application: FC - Quality tested
Recommended Usage: Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application. * StarBright UltraViolet 740 has a maximum excitation of 343 nm and a maximum emission of 737 nm. StarBright dyes are powered by Bio-Rad®. STARBRIGHT is a trademark of Bio-Rad Laboratories, Inc.
Excitation Laser: Ultraviolet Laser (355 nm)
Application Notes: Clone S21016F can completely block the binding of clone “90” on target cells.
Structure: ADP-ribosyl hydrolase, 42 kD
Distribution: B cells, NK cells, T cell subset, brain, muscle, kidney
Function: Regulation of cellular activation/proliferation, adhesion, metabolism of cADPR and NAADP
Ligand/Receptor: CD31, hyaluronic acid
Cell Type: B cells, Lymphocytes, NK cells, T cells
Biology Area: Cell Biology, Costimulatory Molecules, Immuno-Oncology, Immunology
Molecular Family: CD Molecules
Antigen References: Barclay AN, et al. 1997. The Leukocyte Antigen FactsBook Academic Press. Shubinsky G, et al. 1997. Immunity. 7:315-24. Cesano A, et al. 1998. J Immunol. 160:1106-15. Cockayne DA, et al. 1998. Blood. 92:1324-33.
Gene ID: 12494
UniProt: View information about CD38 on UniProt.org
Clone: S21016F
Regulatory Status: RUO
Other Names: T10
Isotype: Rat IgG2b, κ
Q: What is a “StarBright panel”?
A: A StarBright panel is a multiplex panel that includes at least one StarBright conjugate.
Q: Will my StarBright panel be provided as a cocktail?
A: StarBright products purchased as part of a panel or StarBright Basic Panel will be provided in individual vials. To order premade cocktails, please contact our Custom Solutions Team.
Q: Are StarBright GMP/ASR products available?
A: StarBright ASR and GMP products are coming soon.
Q: Are StarBright custom products available?
A: Yes, please contact our Custom Solutions Team.
Q: Will StarBright isotype controls be offered?
A: We are not planning to offer StarBright isotype controls at this time. Fluorescence Minus One (FMO) controls should be used to define gating boundaries.
Q: What amount of a StarBright conjugate should I use?
A: Antibody conjugates should be titrated for optimal performance in each application. To directly compare performance with a traditional or polymer-conjugated antibody, we recommend using the same volume of each product for analysis. Due to differences in the quantification of product mass, StarBright Dyes are prepared in equivalent volumes.
Q: Why shouldn’t I compare the mass (μg) of a StarBright conjugate to a traditional or polymer conjugate?
A: For StarBright conjugates, the reported mass refers to the mass of the dye component. For traditional conjugates, the reported mass refers to the mass of the antibody component. This is because traditional conjugates have multiple dye molecules attached to one antibody, while StarBright conjugates have multiple antibodies attached to a single StarBright Dye.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924