Biolegend, 985206, APC anti-human CD69, 500microl

CATALOG NUMBER: 985206
السعر العادي$0.99
/
  • ddddd

    99 xxxxxx

  • الطلب مؤجل، سيتم الشحن قريباً

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

CD69 is a 27-33 kD type II transmembrane protein also known as activation inducer molecule (AIM), very early activation antigen (VEA), and MLR3. It is a member of the C-type lectin family, expressed as a disulfide-linked homodimer. Other members of this receptor family include NKG2, NKR-P1 CD94, and Ly49. CD69 is transiently expressed on activated leukocytes including T cells, thymocytes, B cells, NK cells, neutrophils, and eosinophils. CD69 is constitutively expressed by a subset of medullary mature thymocytes, platelets, mantle B cells, and certain CD4 + T cells in germinal centers of normal lymph nodes. CD69 is involved in early events of lymphocyte, monocyte, and platelet activation, and has a functional role in redirected lysis mediated by activated NK cells.
500microl
Reactivity: Human
Formulation: Phosphate-buffered solution, pH7.2, containing 0.09% sodium azide, 0.2% (w/v) BSA (origin USA), and a stabilizer.
Preparation: The antibody was purified by affinity chromatography and conjugated with APC under optimal conditions.
Concentration: 100 µg/mL
Storage & Handling: The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application: Suggested for Flow Cytometry
Disclaimer: WARNINGS AND PRECAUTIONS Use appropriate personal protective equipment and safety practices per universal precautions when working with this reagent. Refer to the reagent safety data sheet. This antibody contains sodium azide. Follow federal, state and local regulations to dispose of this reagent. Sodium azide build-up in metal wastepipes may lead to explosive conditions; if disposing of reagent down wastepipes, flush with water after disposal. All specimens, samples and any material coming in contact with them should be considered potentially infectious and should be disposed of with proper precautions and in accordance with federal, state and local regulations. Do not use this reagent beyond the expiration date stated on the label. Do not use this reagent if it appears cloudy or if there is any change in the appearance of the reagent as these may be an indication of possible deterioration. Avoid prolonged exposure of the reagent or stained cells to light.
Antigen References: Schlossman S, et al. 1995. Oxford University Press. Testi R, et al. 1994. Immunol Today. 15:479-83.
Clone: FN50
Workshop: IV A91
Other Names: Very Early Activation Antigen (VEA), Activation inducer molecule (AIM)
Isotype: Mouse IgG1, κ