Iright
BRAND / VENDOR: Waters

Waters, 186000434, XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pk

CATALOG NUMBER: 186000434
Regular price$0.99
/
Shipping calculated at checkout.
  • ddddd

    99 xxxxxx

  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Hybrid
pH Range Min: 2 pH
pH Range Max: 12 pH
Maximum Pressure: 6000 psi (415 Bar)
Endcapped: Yes
Bonding Technology: Shield RP18
Silanol Activity: Low
Particle Shape: Spherical
Particle Size: 3.5 µm
Endfitting Type: Waters
Pore Size: 125 Å
Format: Column
Surface Area: 175
System: HPLC
USP Classification: L1
Inner Diameter: 4.6 mm
Length: 50 mm
Carbon Load: 15 %
UNSPSC: 41115709
Brand: XTerra
Product Type: Columns
Units per Package: 1 pk

Additional Information
XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pk Mechanical strength, extremely spherical shape, purity, pore dimensions, surface area, ability to customize particle size, pore dimensions, surface area, and surface chemistry are all advantages of the Waters XTerra Shield RP18 column. Traditional bonding agents are used to accomplish this. As a result, the XTerra Shield RP18 columns are versatile and capable of providing optimal shape performance for strongly basic chemicals while maintaining good separation efficiency and pH stability. The XTerra Shield RP18 columns have a wide pH range of operation. The XTerra Shield RP18 column's high purity methyl hybrid material is made in a similar way as high-purity silica, with one important difference: the XTerra material is made from the combined condensation of two high purity monomers rather than one. The Hybrid Particle Synthesis of the XTerra Shield RP18 columns is done with tetraethoxysilane (TEOS) and methyltriethoxysilane (MTEOS). The lab equipment is made under ISO 9001 conditions, guaranteeing that each stage is carried out to the highest standards and with the tightest tolerances possible. To determine its performance, each column is carefully tested. Each column comes with a certificate of batch analysis and column efficiency. Shop for this and other lab equipment that is available in our wide selection of chromatographic equipment, all manufactured to the highest standards. The Waters XTerra Shield RP18 reversed-phase HPLC lab equipment uses Waters patented organic/inorganic Hybrid Particle Technology (HPT) to overcome the significant limitations of silica-based reversed-phase packing materials, particularly their hydrolytic instability at high pH, making the Waters XTerra family of reversed-phase HPLC columns the first commercially available alternative to silica-based column technology. Use the XTerra Shield RP18 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk in conjunction with the XTerra Shield RP18 Column in order to protect the lab equipment from harm caused by unwanted particulate or chemical materials.

FAQ
Does The XTerra Shield RP18 Column Offer A Wide pH Range? The XTerra Shield RP18 column listed here offers a wide operating pH range of 2 - 12. What Is The Maximum Pressure That The XTerra Shield RP18 Column Can Offer? The XTerra Shield RP18 column listed here offers a maximum operating pressure of 6000 psi (415 Bar), given that other limits such as pH and temperature are also followed.


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924