Iright
BRAND / VENDOR: Waters

Waters, 186008756, ACQUITY UPLC Peptide HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1K - 15K, 1/pk

CATALOG NUMBER: 186008756
السعر العادي$0.99
/
  • ddddd

    99 xxxxxx

  • الطلب مؤجل، سيتم الشحن قريباً

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

ACQUITY UPLC Peptide HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1K - 15K Columns are designed for separations where silica-based selectivities are desired or when increased retention of hydrophilic peptides are required. Each batch of HSS T3, 100Å material is QC tested with a gradient separation of a tryptic digest of cytochrome c (p/n: 186006371) and must pass stringent performance criteria before acceptance for use in these columns. 2.1mm ID columns are recommended for use with low dispersion (UPLC or UHPLC) systems, especially for LC-MS methods.

Specifications
Chemistry: C18
Separation Mode: Reversed Phase
Particle Substrate: Silica
pH Range Min: 2 pH
pH Range Max: 8 pH
Temperature Limits: 45 C
Maximum Pressure: 18000 psi (1240 Bar)
Endcapped: Yes
Bonding Technology: T3
Silanol Activity: Medium
Molecular Weight Range Min: 1000
Molecular Weight Range Max: 15000
Particle Shape: Spherical
Particle Size: 1.8 µm
Endfitting Type: Parker-style
Pore Size: 100 Å
QC Tested: Peptide
Format: Column
Surface Area: 230
System: UPLC, UHPLC
Particle Technology: HSS
USP Classification: L1
Inner Diameter: 2.1 mm
Length: 150 mm
Carbon Load: 11 %
UNSPSC: 41115709
Application: Peptide
Brand: ACQUITY UPLC
Product Type: Columns
Units per Package: 1 pk

FAQ
What Is Sensitivity Within Chromatography? Sensitivity refers to the signal output per unit concentration or unit mass of a substance in the mobile phase entering the detector, as an example, the slope of a linear calibration curve.

Sensitivity also refers to the ratio of peak height to the analyte concentration in the peak for concentration-sensitive detectors. It is the ratio of peak height to unit mass in mass-flow-sensitive detectors. What Are Some Of The System Limits Using Acquity UPLC Peptide HSS T3 Column? The Acquity UPLC Peptide HSS T3 Column can be operated between a pH range of 2 - 8, with a temperature ceiling of 45 C, and up to a maximum pressure of 15,000 psi (or 1034 Bar).


Order Guidelines

1. Price & Stock Available on Request. 📧Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmation.

3. Minimum order value of $1,000 USD required.

Collaboration

Tony Tang

📧Email: Tony.Tang@iright.com

📱Mobile/WhatsApp/Wechat: +86-17717886924