BRAND / VENDOR: Agilent

Agilent, CP7542, J&W CP-SimDist GC Column, 10 m, 0.53 mm, 0.17 µm, UltiMetal, 7 inch cage

CATALOG NUMBER: CP7542

Regular price$0.99
/
Shipping calculated at checkout.
  • 99 items in stock
  • Backordered, shipping soon

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Product Description

J&W CP-SimDist GC Column, 10 m, 0.53 mm, 0.17 µm, UltiMetal, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.

Specifications:
Agency Method: ASTM D7169
Capillary Tubing: UltiMetal
Film Thickness: 0.17 µm
Format: 7 inch
Inner Diameter (ID): 0.53 mm
Length: 10 m
Phase: CP-SimDist UltiMetal
Polarity: Low Polarity
Temperature Range: 450/450 °C-450/450 °C
UNSPSC Code: 41115710
With Smart Key: No

**********The following product description is generated by AI and is for reference only. If you have any questions, please contact customer service.**********
Designed for high-temperature gas chromatography, this 10-meter, 0.53 mm internal diameter column with a 0.17 µm film leverages UltiMetal technology for enhanced durability and performance, particularly in simulated distillation analyses. Optimized for refinery and petrochemical laboratory settings, the column delivers sharp resolution and reproducible results for boiling point distribution in complex hydrocarbon mixtures, adhering to ASTM and international methodology standards. The inert UltiMetal construction withstands rigorous conditions, minimizing bleed and extending column lifetime even at elevated operating temperatures. Suitable for use with major Agilent GC systems and compatible instruments from other leading manufacturers, it is commonly employed in applications such as ASTM D2887 and D6352 simulated distillation, refining process control, lubricant analysis, and research into fuel formulations. Its 7-inch cage facilitates seamless installation, and the column is engineered for reliable integration into both legacy and modern analytical platforms. This product pairs well with Agilent’s range of high-temperature GC supplies, sample introduction liners, and advanced gas chromatography detectors to further strengthen analytical throughput and data reliability in petroleum and chemical research workflows.

Order Guidelines

1. Price & Stock Available on Request. Click to send email to: service@iright.com

2. Please DO NOT make payment before confirmtaion.

3. Minimum order value of $1,000 USD required.

4. 100% prepayment required.

Collaboration

Tony Tang

Email: Tony.Tang@iright.com

Mobile/WhatsApp/Wechat: +86-17717886924

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)