Sartorius Frozen Storage & Shipping for Bulk Drug Substance (−20°C to −80°C)
103 productsWhen your bulk drug substance (BDS), buffers, media, or cell-based materials must travel or wait at sub-zero temperatures, you need a closed, validated path from fill to thaw. This collection brings together Sartorius solutions for controlled freezing, frozen storage, and qualified cold-chain shipping so you can choose the right bag, frame, platform, and shipper—then request an accurate quote fast.
What Is Frozen Storage & Shipping (in Bioprocess)?
Bioprocess frozen storage & shipping covers the end-to-end workflow of keeping temperature-sensitive fluids safe at −20 °C to −80 °C and moving them between suites, sites, or countries without compromising sterility or product quality. At its core are single-use freezing bags (often in protective shells), controlled freeze–thaw platforms, and pre-qualified shippers with temperature logging to maintain chain of custody and compliance. Solutions like the Celsius® FT100 and FFT/FFTp pair with Celsius® Paks to standardize freezing and thawing while reducing cryoconcentration risks.

Use Cases & Temperature Bands (−20 °C vs −80 °C)
Choosing a temperature band depends on stability, hold time, and transport duration. Use the quick matrix below to match your scenario. Then fine-tune with your QA and lane data.
Use Case | Typical Temp | Typical Format | Working Volumes | Notes |
---|---|---|---|---|
BDS intermediate lots | −80 °C | Celsius® Pak in frame/shell | 1–16.6 L (unit), up to 100 L per module | Controlled plate freezing improves uniformity |
Buffers / media | −20 °C | 2D/3D bags, shells, modules | 2–50 L (typical) | Prioritize uniform thaw and closed transfer |
Cell- or vector-based materials | −80 °C (or lower) | 2D small-volume formats | ≤5 L | Emphasize E&L and sterile welding/sealing |
Inter-site shipment | −80 °C with dry ice | Qualified shipper + SSM | Up to 100 L per shipper | Temperature logging and packaging validation |

Product Categories: Freezing Bags, Frames & Validated Shippers
To speed selection, this collection organizes components by role in your frozen-chain.
-
Single-Use Freezing Bags (Celsius® Paks) – Sterile, ready-to-use bags sized for 1 L, 2 L, 8.3 L, and 16.6 L, designed to work with controlled plate freezers. Frames, carriers, and storage modules extend handling and throughput.
-
Freeze–Thaw Platforms (Celsius® FT/FFT) – The Celsius® FT100 provides controlled-rate freeze and thaw for 1–16.6 L Paks; Celsius® FFT/FFTp is a bag-in-shell system that leverages existing freezers and simplifies scale-up.
-
Validated Shippers & Modules – SSM modules store up to 100 L of frozen Paks and drop directly into pre-qualified SSM or single-unit shippers for dry-ice transport to remote sites. Flexsafe® “bag-in-shell” options round out liquid shipping at 5/10/20 L.

How to Choose: A 3-Step Freeze–Thaw Selection Guide
Before you compare product numbers, align on these three decisions; they determine freezing kinetics, handling, and documentation.
-
Medium × Temperature – Map your fluid (protein/BDS, buffer/media, cell-related) to −20 °C vs −80 °C based on stability and travel time.
-
Volume × Form Factor – Pick 2D Pak capacity (1–16.6 L) and whether you need frames, carriers, or shells for racking, stacking, and impact resistance.
-
Connectivity × Compliance – Confirm aseptic connectors/welding, venting strategy (e.g., MPC vs filter), and the validation package you require (E&L, gamma sterility, drop/transport testing).
This reduces iteration and ensures any quote reflects the configuration you’ll actually run.
Featured Models & Specs (Celsius® / Flexsafe®) — Verified SKUs
Below are representative, high-intent SKUs validated against the Sartorius eShop. Use them as starting points for quoting and internal alignment.
Catalog No. | Product | Format / Volume | Connectors / Notes |
---|---|---|---|
CFT-FT100 | Celsius® FT100 Freeze & Thaw System | Platform for 1, 2, 8.3, 16.6 L Paks | Controlled-rate freeze/thaw |
FZB115319 | Celsius® Pak | 1 L | MPC inlet/outlet; sterile vent option |
FZB115322 | Celsius® Pak | 2 L | MPC inlet/outlet; sterile vent option |
FTH-CF00016-0009 | Celsius® Pak Frame 2G | Frame for 16.6 L Pak | Handling & racking |
FTH-SM00101-0024 | Celsius® Shippable Storage Module (SSM) | Holds up to 100 L of frozen Paks | Drops into SSM shipper |
FTH-SM00101-0028 | Celsius® SSM Shipper | Qualified dry-ice shipper | For remote transport |
FTH-SM00102-0002 | Celsius® Pak Single-Unit Shipper | 16.6 L payload | Pre-qualified shipper |
FLS303107 | Flexsafe® 2D Bag in Shell | 5 L | MPC ↔ MPC |
FLS303109 | Flexsafe® 2D Bag in Shell | 10 L | MPC ↔ MPC |
FLS303815 | Flexsafe® 2D Bag in Shell | 20 L | MPC ↔ MPC |
FLA302701 | Standalone Shell for Flexsafe® 2D | 5 L shell | Transport protection |
FLA302721 | Standard Shipper for Flexsafe® 2D Shell | 5 / 10 / 20 L options | Qualified package |
Freeze–Thaw Workflow: From Fill to Thaw
A consistent, well-documented workflow protects quality and simplifies tech transfer. The steps below mirror how teams run BDS lots through freezing and shipment.
- Fill (Closed): Use sterile connectors/welding and a defined venting approach (e.g., Midisart® BV filter) to minimize bioburden and ensure label traceability.
- Controlled Freeze: With FT100 or plate-freezer setups, target even heat flux to limit cryoconcentration and ice front gradients—key to batch-to-batch consistency.
- Package & Ship: Place frozen Paks into SSMs or single-unit shippers with dry-ice load plans; add temperature logging and handling SOPs for lane validation.
- Thaw & Use: Bring product back under controlled conditions for uniform thaw, then dispense through your closed manifold to the next unit operation.
Compatibility & Accessories for Seamless Integration
Most teams ask “Will this connect to our current line?” This section is your shortcut. Celsius® logistic accessories include Pak frames, carriers, SSM modules/shippers, and trolleys; Flexsafe® shells and standard shippers cover 5/10/20 L liquid shipping. On your site, link this section to Tubing & Assemblies, Liquid Storage & Shipping, Temperature/Data Loggers, Validation Services, and Palletank® pages so users can finish a build without leaving the ecosystem.
FAQs: −20 °C vs −80 °C, 2D vs 3D, Shipping Time, Reuse
1. How do I pick −20 °C vs −80 °C?
Match to molecular stability and time in transit. BDS lots and long hauls typically use −80 °C with dry ice; buffers/media often run at −20 °C.
2. Do I need a bag-in-shell?
Shells add impact resistance, stacking, and ergonomic handling. They are standard for higher volumes or when shipping to remote sites.
3. What about validation documents?
Sartorius provides sterility (gamma/ISO 11137), E&L, and transport testing documentation for relevant SKUs; shippers and shells are qualified against rigorous norms.
4. Will FT100/FFT work with my existing freezers?
FT100 is a dedicated controlled-rate system; FFT/FFTp is designed to leverage commercially available equipment for freeze–thaw.
Get a Quote or Samples — Contact Iright for Trusted Supply
Ready to scope your build? Contact Iright to request a quote or samples. Tell us your target temperature (−20 °C or −80 °C), per-batch volume, connectors/venting preference, and shipping duration. Our team validates each configuration against Sartorius documentation and verified SKUs before pricing, so you receive a dependable proposal that aligns with GMP expectations and lane requirements. Contact Iright to move from evaluation to execution with confidence.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make any payment before confirmation.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924