Filter

    Thermo Fisher Incubators for Cell Culture, Microbiology & Growth

    244 products

    Thermo Fisher incubators provide stable, contamination-aware environments for cell culture, microbiology, and temperature-controlled growth. This Collection page helps you compare lines, filter by critical specs, and choose the right chamber for your workflow. As a distributor, Iright offers a broad selection of Thermo Fisher models plus fast quotes and local support.

    Why Choose Thermo Fisher Incubators for Cell Culture

    Thermo Fisher’s portfolio combines precise temperature and gas control with fast recovery and strong contamination defenses. When your cultures depend on repeatability, you need chambers that minimize drift, simplify cleaning, and keep uptime high, while offering documented performance for regulated labs and demanding academic cores.

    Thermo Fisher incubators emphasize uniformity, recovery time after door openings, and contamination control. Depending on the line, you’ll see features such as direct-heat or water-jacketed designs, HEPA filtration, 180 °C high-heat sterilization cycles, copper-enriched interiors, humidity management, and options for data logging, alarms, and remote monitoring.

    Incubator Types & Applications: CO₂, General, Shaking, Refrigerated & Tri-Gas

    Selecting by application first prevents over- or under-specifying your chamber. Once the type is correct, you can refine details like volume, atmosphere, and decontamination. The overview below maps common research needs to suitable Thermo Fisher lines so you can evaluate confidently.

    • CO₂ Incubators (Mammalian cell culture): Maintain 37 °C, controlled CO₂ (typically ~5%), and high humidity to stabilize pH in bicarbonate-buffered media. Consider Heracell™ and Forma™ CO₂ lines for precision, fast temperature/CO₂ recovery, and contamination control.

    • Tri-Gas / Hypoxia (Low-oxygen studies): Add O₂ control for hypoxia or hyperoxia research. Selected CO₂ lines offer optional O₂ regulation for stem cell work, tumor biology, and metabolic studies.

    • General-Purpose Incubators (Microbiology, stability, drying): For ambient-atmosphere growth, enzyme reactions, and stability protocols, Heratherm™ offers gravity or mechanical convection choices, broad temperature ranges, and efficient footprint options.

    • Incubated Shakers (High-throughput culture with agitation): For bacterial/yeast growth and expression work, MaxQ™ incubated shakers deliver orbital shaking with controlled temperature and easy-to-clean chambers.

    • Refrigerated / Wide-Range Chambers: When protocols require sub-ambient operation or profiles across a range of temperatures, look for refrigerated models or wide-range general incubators.

    Quick Model Finder: Filter by CO₂/O₂ Control, Temperature, Volume & Decontamination

    The fastest way to build a shortlist is to filter on parameters tied to culture viability, contamination risk, and room constraints. Use the following facets to reduce noise and keep only the models that truly match your lab’s needs.

    Suggested filters for this Collection

    • Atmosphere: CO₂ only / CO₂ + O₂ (tri-gas) / Ambient

    • Temperature Range: e.g., RT + 5 to 60 °C; 4–60 °C; wide-range options

    • Humidity Method: Passive reservoir / active control (where available)

    • Decontamination: 180 °C high-heat cycle / HEPA filtration / UV support / copper-enriched interior

    • Chamber Volume (L): ≤ 80 L / 80–200 L / ≥ 200 L

    • Convection: Gravity / mechanical

    • Shaking Capability: Yes/No; RPM range; orbit (mm)

    • Interior Material: Stainless steel / copper-enriched stainless

    • Recovery & Uniformity: Target recovery time (temp/CO₂); uniformity spec

    • Connectivity: Data logging/alarms / remote monitoring readiness

    • Footprint & Power: External dimensions; lab electrical compatibility

    • Compliance: Cleanroom-friendly options; GMP/GLP documentation support

    Compare Thermo Fisher Lines: Heracell CO₂ vs. Forma CO₂ vs. Heratherm vs. MaxQ

    Comparison helps you balance performance, maintenance effort, and total cost of ownership. Use this high-level table to narrow the field, then open the product cards to review detailed specs, accessories, and documentation before requesting a quote.

    Line (Intended Use) Atmosphere Options Decontamination/Contamination Control Typical Temp Range Chamber Volume Options Notable Attributes
    Heracell™ (CO₂ / Tri-Gas) CO₂; optional O₂ control 180 °C high-heat sterilization (select models), HEPA flow, copper-enriched interiors Cell culture range (e.g., ~room + 5 to 55–60 °C) Bench-friendly to high-capacity Fast recovery, stable humidity/pH control, easy cleaning, audit-friendly options
    Forma™ CO₂ (incl. water-jacketed) CO₂ Water-jacketed or direct-heat designs; contamination-aware features Cell culture range Multiple capacities Water-jacketed thermal stability options; robust chamber construction
    Heratherm™ (General Purpose) Ambient (no CO₂) Cleanability-focused interiors; convection choice Broad lab ranges (e.g., ~+5 to 60–75 °C, model-dependent) Compact to large Gravity/mechanical convection variants; stability and drying workflows
    MaxQ™ Incubated Shakers Ambient (heated or refrigerated variants by model) Easy-clean chamber; spill-resistant platforms Heated or refrigerated ranges (model-dependent) Single/stackable formats High-throughput orbital shaking; accessories for flasks, plates, and tubes
    Thermo Fisher Heracell CO₂

    Editor’s Picks: Best-Selling Incubators by Use Case (Cell Culture, Microbiology, GMP)

    Sometimes it’s easier to begin with the scenario you know. The picks below highlight lines that balance core performance with maintenance and uptime. Use them as a starting point, then adjust capacity, atmosphere, and decontamination to match your protocol.

    • Mammalian Cell Culture & Everyday 37 °C Work — Heracell™ CO₂
      If your priority is consistent pH control, fast temperature/CO₂ recovery, and simplified cleaning routines, start with Heracell. Add O₂ control for hypoxia studies and consider high-heat sterilization for robust contamination defense in multi-user labs.

    • Water-Jacket Stability or Legacy Replacements — Forma™ CO₂
      When a water-jacketed design is preferred for thermal buffering, Forma CO₂ lines offer proven stability with contamination-aware features. They suit teams standardizing on water-jacket platforms or replacing legacy units with minimal process disruption.

    Thermo Fisher Forma™ CO₂
    • Microbiology, Stability, and Drying — Heratherm™ General Incubators
      Choose gravity convection for gentle temperature profiles or mechanical convection for faster heat-up and better uniformity with frequent door openings. These chambers fit media testing, environmental stability checks, and general growth tasks.

    Thermo Fisher Heratherm™ General Incubators
    • High-Throughput Shaking Culture — MaxQ™ Incubated Shakers
      For bacterial/yeast expression and screening, MaxQ platforms deliver orbital shaking with reliable temperature control. Look for stackable formats and platform accessories to scale capacity without expanding your footprint.

    Thermo Fisher MaxQ™ Incubated Shakers

    Selection Guide: Temperature Uniformity, Recovery, Contamination Control & Upkeep

    Good incubator choices start from biology and back into hardware. Prioritize variables that protect your cultures day after day and reduce rework and downtime in busy spaces or regulated labs.

    Consider the following when selecting a Thermo Fisher incubator:

    • Uniformity & Recovery: Check uniformity (°C across chamber) and recovery times after door openings for both temperature and CO₂. Faster recovery reduces pH swings and variability in sensitive cell lines.

    • Atmosphere Control: Confirm CO₂ accuracy, stability, and (if needed) O₂ control ranges. For hypoxia studies, ensure setpoint resolution and sensor strategy fit your protocols.

    • Decontamination Strategy: High-heat cycles (e.g., 180 °C), HEPA filtration, copper-enriched interiors, and UV options reduce contamination risk. Match the method to usage patterns, user count, and cleaning SOPs.

    • Humidity & Condensation: Evaluate humidity generation and condensation management to reduce desiccation and contamination.

    • Capacity & Layout: Size the chamber for current and future throughput; verify shelf load ratings, usable height, and compatibility with flasks, plates, and bioreactors.

    • Ease of Cleaning & Maintenance: Smooth interiors, removable components, and tool-less service points shorten downtime.

    • Connectivity & Compliance: Data logging, alarms, and audit-friendly exports help with GLP/GMP documentation and facility monitoring.

    • Footprint, Noise & Power: Check external dimensions, stacking options, heat output, and electrical requirements for your room.

    FAQs: CO₂ vs. General, Water-Jacketed vs. Direct-Heat, 180 °C Sterilization, Hypoxia

    Choosing the right chamber often comes down to a few recurring questions. Use these quick answers to align on fundamentals, then apply the selection guide above to finalize your shortlist.

    • CO₂ vs. General-Purpose—what’s the difference?
      CO₂ incubators regulate carbon dioxide and humidity to stabilize pH for mammalian cell culture. General incubators run at controlled temperature in ambient air and fit microbiology, stability, and drying tasks that don’t need CO₂.

    • Water-Jacketed vs. Direct-Heat—how should I choose?
      Water-jacketed designs offer thermal buffering against rapid swings and can be forgiving during brief power interruptions; direct-heat units warm up faster, weigh less, and eliminate water maintenance. Pick based on your lab’s process and service preference.

    • Do I need 180 °C sterilization if I already have HEPA?
      HEPA filtration reduces airborne particulates during operation. A 180 °C high-heat cycle is a periodic decontamination step that helps break contamination chains in multi-user labs or after spill events. Many teams use both for layered defense.

    • When is O₂ control necessary?
      Hypoxia models support cell types and disease models that require low oxygen environments. If your protocols call for defined O₂ setpoints or gradients, choose a tri-gas unit with the needed O₂ range and stability.

    • How big should my chamber be?
      Size for your current weekly load plus headroom for peak weeks, accounting for flasks/plates height, shaker platform clearance (if applicable), and shelf load ratings. Avoid over-sizing to prevent unnecessary energy use and footprint.

    Talk to Iright: Get Pricing, Specs & Availability for Thermo Fisher Incubators

    When you’re ready, share your required atmosphere (CO₂ / tri-gas), target temperature range, chamber volume, and preferred decontamination method. Iright will assemble a focused quote from Thermo Fisher lines—Heracell, Forma, Heratherm, and MaxQ—along with lead times, accessories, and documentation to help you move from selection to setup smoothly.

    Order Guidelines

    1. Price & Stock Available on Request. Click to send email to: service@iright.com

    2. Please DO NOT make any payment before confirmation.

    3. Minimum order value of $1,000 USD required.

    4. 100% prepayment required.

    Collaboration

    Tony Tang

    Email: Tony.Tang@iright.com

    Mobile/WhatsApp/Wechat: +86-17717886924