Filter

    Waters Standards & Reagents for LC/MS, HPLC & GC

    415 products

    When your results must be comparable day after day, you start with dependable materials. Waters Standards & Reagents provide the reference points your methods rely on—system suitability mixes, calibration standards and QC materials, LC/MS-grade solvents and additives, and certified reference materials for regulated programs. You get traceable documentation, lot-to-lot consistency, and formats suited to UPLC/HPLC/LC-MS, GC, and SFC workflows.

    What Are Waters Standards & Reagents?

    These are the components that make analytical results verifiable rather than approximate. By supplying known composition and performance data, they let you benchmark instruments, build calibration curves, validate methods, and control background—so numbers are defensible in audits and transferable between sites.

    Waters provides several families: system suitability standards to check peak shape, resolution, and sensitivity; calibration and quality control standards to construct curves and monitor accuracy; LC/MS-grade solvents and additives to minimize background and improve ionization; and certified reference materials (CRMs) and proficiency testing (PT) from ERA (a Waters company) to support accreditation programs.

    Product Categories: Calibration Standards, LC/MS-Grade Solvents, Additives & CRMs

    To help you scan quickly, the portfolio below is organized by how you use it. Start with the routine checks, then choose materials for quantitation, and finish with the solvents/additives and reference materials that keep backgrounds low and traceability clear.

    System Suitability Standards (SST/QCRM): Multi-component mixes designed to prove chromatographic and MS readiness before critical runs (for example, LCMS QCRM 186006963). Use to confirm response, retention, and resolution across common methods.

    Waters LCMS QCRM - Contact Iright for Price

    Calibration & QC Standards: Application-oriented mixes and digestion standards (e.g., MassPREP Enolase 186002325; MassPREP ADH 186002328) for curve building and routine control.

    Waters MassPREP Enolase - Contact Iright for Price

    LC/MS-Grade Solvents & Additives: Kits of acetonitrile, methanol, isopropanol, and water, plus formic acid and other modifiers, packaged for low background and consistent ionization (e.g., 186008715, 186009188, 186009203, 186006691).

    Protein & Biologics Standards: Materials such as the Intact mAb Mass Check Standard (186006552) to optimize and verify MS for large molecules.

    Waters Intact mAb Mass Check Standard - Contact Iright for Price

    CRMs & Proficiency Testing (ERA): ISO/NELAC-accredited CRMs and PT samples for environmental and process water programs, with COAs and schedules for compliance.

    How to Choose for Your Method (UPLC/HPLC/LC-MS/GC/SFC)

    Selection is easiest when you align technique, matrix, and regulatory context. Start from the analyte class and sensitivity target, then match the standard type, solvent grade, and documentation you’ll need for QA review or accreditation.

    Decision guide (quick reference):

    Technique Typical purpose Recommended materials Notes
    UPLC/HPLC-MS Daily readiness + low background LC/MS-grade solvent kit 186008715; water kit 186009203; ACN kit 186009188 Use ultra-pure water and LC/MS-grade organics to avoid ionizable contaminants.
    LC-MS/MS quantitation Calibration + QC Application standards (e.g., MassPREP 186002325/186002328) + appropriate internal standards Confirm concentration range and storage on the COA.
    System health check (LC/MS) Benchmarking performance LCMS QCRM 186006963 Multi-analyte mix covering ESI+/– and broad m/z; includes storage guidance.
    Biologics MS Optimization & setup Intact mAb Mass Check Standard 186006552 Designed for routine MS optimization and performance testing.
    Environmental/process water QA Compliance & accreditation ERA CRMs + PT ISO/NELAC-accredited materials with COAs and program schedules.

    Quality, Traceability & Documentation (COA, SDS, IFU)

    Audit-ready labs document what went into every result. For each product, confirm that the lot-specific COA and SDS are accessible, and retain any use instructions (IFU) with your method records to support reviews and transfers.

    • Lot control & COAs: Waters product pages provide lot-specific COAs; ERA offers a COA request portal for all CRMs. Save COAs with batch records and instrument logs. 
      prod1.
    • SDS & IFU: Download directly from the product page or documentation center and attach to the method file for QA sign-off.
    • Traceability: ERA CRMs/PT are covered by globally recognized accreditations (ISO 17034/17025 and NELAC), helping satisfy internal and regulatory requirements.

    Storage, Handling & Safety for Standards, Solvents & Additives

    Performance depends on how you treat the materials. Check each product’s COA for temperature, light sensitivity, and shelf life after opening, and align your SOPs with the most restrictive requirement to preserve stability.

    For example, LCMS QCRM ships at ambient temperature but should be refrigerated at 4 °C for short-term storage and frozen for longer-term stability. Many protein or peptide standards (e.g., MassPREP digestion standards) are supplied lyophilized; once reconstituted, follow the COA for in-use life and freeze aliquots to avoid repeat freeze–thaw cycles. LC/MS-grade solvents and formic acid are flammable—store in approved cabinets and handle in a fume hood as appropriate.

    Checklist (quick scan): keep unopened kits in original amber bottles; label reconstitution solvent and date; aliquot when possible; protect from light; segregate acids and organics; record lot numbers in LIMS and on instrument suitability logs.

    Applications & Use Cases: Pharma QC, Environmental, Food, Clinical LC-MS/MS

    Whether you’re qualifying a new method or maintaining a validated one, these materials plug into everyday workflows. The examples below outline typical fits so you can connect categories to outcomes without repeating previous content.

    • Pharma QC & Method Transfer: Use LCMS QCRM or technique-specific QCRMs to confirm chromatographic and MS performance at installation and before batches. For peptide/protein assays, add digestion or intact mass standards to optimize sensitivity and charge state distribution prior to sample runs.
    • Environmental & Process Water: Pair ERA PT samples with matching CRMs for TOC, conductivity, and ions to verify accuracy while maintaining accreditation. COAs and study schedules simplify documentation.
    • Food & Beverage Authenticity & Safety: LC/MS-grade solvents and appropriate standards support multi-residue methods and non-targeted fingerprinting where background control and reproducibility are essential.
    • Clinical LC-MS/MS (RUO/IVD as applicable): Use application-specific kits and system suitability mixes to reduce troubleshooting time and keep quantitation robust; confirm regulatory status on the product page before use.

    Featured SKUs & Specs (Waters Part Numbers & Compatibility)

    If you already know what you need, start here. The table summarizes key identifiers and compatible techniques so you can compare quickly and jump to product pages for full specifications and lot-specific documents.

    Part Number Product Name / Type Category Technique Compatibility Key Specs / Notes
    186008715 LC-MS Grade Solvent Kit (ACN, MeOH, IPA, Water; 4 × 1 L) LC/MS-grade solvents LC-MS/UPLC/HPLC Four 1-L amber bottles; low background for ESI.
    186009203 LC-MS Grade Water Solvent Kit (2 × 1 L) LC/MS-grade solvents LC-MS/UPLC/HPLC Ultra-pure water in amber glass; for low-ion background.
    186009188 LC-MS Grade Acetonitrile Solvent Kit (2 × 1 L) LC/MS-grade solvents LC-MS/UPLC/HPLC LC-MS-grade ACN; packaged for cleanliness and safety.
    186006691 Formic Acid, 1 mL glass ampule (98%) Additive LC-MS/UPLC/HPLC Common modifier for improved ionization; single-use ampule.
    186006963 LCMS QC Reference Standard (9-component mix) System suitability / QCRM LC-MS (ESI+/–, APCI+) Storage: refrigerate (short-term) or freeze (long-term); 500 µL vial.
    186002325 MassPREP Enolase Digestion Standard Calibration / QC LC-MS (proteomics) Lyophilized; use per COA for reconstitution and stability.
    186002328 MassPREP ADH Digestion Standard Calibration / QC LC-MS (proteomics) Lyophilized; sequencing-grade trypsin digest.
    186004135 MassPREP OST Oligonucleotide Standard Calibration / QC LC-MS (oligos) Part number referenced in Waters app notes for oligo workflows.
    186006552 Intact mAb Mass Check Standard Protein/biologics standard LC-MS (biologics) For routine MS optimization and setup.
    176004949 SARS-CoV-2 LC-MS System Suitability Set (RUO) System suitability set LC-MS/MS Product page includes COA download and contents list.

    FAQ: LC/MS-Grade Solvents, Calibration vs QC, Documents & Stability

    These concise answers address the most common points of friction when adopting or standardizing on this portfolio. Use them to speed internal reviews and reduce back-and-forth with QA.

    1. What’s the difference between a calibration standard and a QC material?

    Calibration standards establish the curve you quantify against; QC materials are separate checkpoints used to verify accuracy and precision across runs or lots. Use both to detect drift early.

    2. How do I access COAs and SDS?

    Use the Download COA link on Waters product pages and the COA portal for ERA CRMs; store PDFs with your method records.

    3. Which solvent grade should I choose for LC-MS?

    Use LC/MS-grade organics and ultra-pure water to reduce ionizable impurities and noise; lower grades risk background and adducts that hurt sensitivity.

    4. How long are standards stable after opening or reconstitution?

    Follow the product COA/IFU. For instance, LCMS QCRM is refrigerated short-term and frozen for long-term storage; many digestion standards recommend aliquots to avoid multiple freeze–thaw cycles.

    Request a Quote and Rely on Proven Industry Reputation

    If you want a pre-screened shortlist or need documents checked before purchase, we’ll do it for you. Tell us your technique, matrix, and target analytes; we’ll confirm availability, include COA/SDS links, and provide a quote that aligns with your workflow and compliance needs.

    Request a Quote — Share your method context (UPLC/HPLC/LC-MS/GC/SFC), expected concentration range, and any storage or shipping constraints (e.g., cold-chain or flammable). We’ll return options that minimize troubleshooting and keep results consistent lab-to-lab.

    Order Guidelines

    1. Price & Stock Available on Request. Click to send email to: service@iright.com

    2. Please DO NOT make any payment before confirmation.

    3. Minimum order value of $1,000 USD required.

    4. 100% prepayment required.

    Collaboration

    Tony Tang

    Email: Tony.Tang@iright.com

    Mobile/WhatsApp/Wechat: +86-17717886924