Filter

    Waters Application Kits: Faster, Reproducible LC-MS

    150 products

    Waters Application Kits give you an end-to-end, “ready-to-run” workflow for specific analytes and matrices. Each kit bundles validated consumables and method guidance so you can move from sample to result faster, with fewer variables and more reproducible outcomes across UPLC/LC-MS platforms.

    What Are Waters Application Kits?

    These kits combine sample-prep components, LC/UPLC columns, vials, standards/reagents, and concise method notes that have been verified to work together. You adopt a proven recipe instead of assembling parts yourself, reducing rework and shortening method development time from the first run.

    At a glance (typical contents)

    • Sample preparation module (e.g., SPE, digestion, labeling)
    • LC/UPLC column(s) and compatible accessories
    • Reagents/standards and simple protocols for setup and QC

    Core LC-MS Applications & Use Cases

    Start by matching your analytical goal to the kit family optimized for that chemistry. Kits span biomolecules and small molecules, covering routine quantification as well as advanced characterization, so you can standardize workflows across teams and instruments with minimal method drift.

    Waters Core LC-MS System
    • Amino acids in biological samples (derivatization + UPLC separation) — AccQ•Tag Ultra/UPLC AAA.
    • N-glycan profiling with high sensitivity fluorescence/MS readout — GlycoWorks RapiFluor-MS.
    • Protein/peptide quantification via surrogate peptides in plasma/serum — ProteinWorks eXpress/Direct Digest.
    • Oligonucleotide bioanalysis from complex matrices — OligoWorks SPE workflows.

    How Application Kits Accelerate LC-MS Workflows

    You get consistency because critical steps—cleanup, derivatization, digestion, separation—are harmonized under one protocol. Reagents are pre-measured, methods are automation-friendly, and documentation guides validation, which together improves repeatability and shortens the path to reportable data.

    Why it’s faster and more reproducible

    • Pre-optimized chemistries reduce trial-and-error and batch variability.
    • Lot-traceable reagents and defined protocols simplify transfer between sites.
    • Automation scripts and plate-based formats speed high-throughput prep.

    Product Families: GlycoWorks, AccQ-Tag Ultra, ProteinWorks, OligoWorks

    Each family targets a distinct analyte class and preparation strategy. Use the summaries below to quickly narrow choices before you review specific SKUs and method notes.

    • GlycoWorks RapiFluor-MS — three-step N-glycan release, labeling, and cleanup with strong fluorescence and MS response; available in multiple sample counts.
    Waters GlycoWorks RapiFluor-MS Label 96-Sample
    • AccQ•Tag Ultra/UPLC AAA — robust amino-acid derivatization kits underpinning Waters’ UPLC AAA application solution and UV detection workflows.
    Waters AccQ•Tag Ultra/UPLC AAA
    • ProteinWorks eXpress/Direct Digest — pre-measured digestion reagents and protocols for whole or immunopurified plasma/serum, designed for LC-MS quantification via surrogate peptides.
    Waters ProteinWorks eXpress
    • OligoWorks SPE — WAX-sorbent SPE plates/cartridges plus digestion module and eluents for high oligonucleotide recoveries and enhanced LC-MS performance.
    OligoWorks SPE

    Selection Guide: Choose by Analyte, Matrix & Platform (UPLC/LC-MS)

    Use this quick matrix to jump to the right kit family. Filter by what you’re measuring, where it lives, and the prep you prefer; then confirm the matching SKU in the featured table.

    Analyte class Typical matrix Prep highlight Platform focus Recommended family
    Amino acids Plasma, cell lysate, hydrolysates AccQ•Tag derivatization UPLC + UV/LC-MS AccQ•Tag Ultra / UPLC AAA
    N-glycans mAbs, glycoproteins RapiFluor-MS label + cleanup LC-FLR/LC-MS GlycoWorks
    Tryptic peptides (surrogate) Whole or immunopurified plasma/serum Pre-measured digestion reagents LC-MS/MS ProteinWorks eXpress / Direct Digest
    Oligonucleotides Plasma, serum, tissues WAX SPE + pretreatment LC-MS OligoWorks SPE

    Featured Kits & SKUs (Validated Waters Catalogs)

    Below are representative kits many labs start with. Each entry lists the family, catalog number, and primary use so you can request a quote confidently and map to your method files.

    Kit / Family Catalog No. Target / Use Included (summary) Platform Notes
    GlycoWorks RapiFluor-MS N-Glycan Kit, 96-sample 176003606 Release, label, and analyze N-glycans with strong FLR/MS response RapiFluor-MS reagents and cleanup materials for 96 samples LC-FLR/LC-MS Three easy steps; streamlined sample prep.
    GlycoWorks RapiFluor-MS N-Glycan Starter Kit, 24-sample 176003712 Starter format for method setup and small studies Materials for 24 samples; refill available separately LC-FLR/LC-MS Good for pilots and training.
    AccQ•Tag Ultra Derivatization Kit 186003836 UPLC AAA workflows for amino acids Derivatization reagents and method documentation UPLC + UV/LC-MS Component of UPLC AAA solution.
    AccQ•Tag Ultra Derivatization Kit – Automation 186009232 Automated AAA sample prep Automation-oriented kit configuration UPLC + UV/LC-MS Streamlines high-throughput AAA.
    ProteinWorks eXpress Direct Digest Kit 176003688 Direct digestion of whole plasma/serum for LC-MS Pre-measured reagents, optimized protocol LC-MS/MS Reduces prep time and variability.
    ProteinWorks eXpress Direct Digest Start-up Kit 176003695 Bundle for immediate adoption Direct Digest kit + µElution SPE cleanup + mAb standard LC-MS/MS Convenient all-in-one start.
    OligoWorks SPE Microplate Kit 186010614 Oligonucleotide extraction/cleanup 96-well WAX SPE plate, Proteinase K module, eluent, protocol LC-MS Automation-friendly design.
    OligoWorks SPE 3 cc Cartridge Kit 186010616 Cartridge-based SPE for oligos 3 cc WAX cartridges (60 mg), digestion module, eluent, protocol LC-MS High recovery across matrices.

    Compatibility & Required Accessories for LC/UPLC & LC-MS

    Before ordering, confirm the instrument class and small accessories that complete the workflow. Kits are designed to fit LC/UPLC and LC-MS methods, and many include vials or specify vial/cap formats to protect integrity from prep to injection.

    Checklist

    • Verify LC/UPLC system and detector (UV/FLR/MS) match the method.
    • Ensure appropriate vials, caps, and column formats are on hand.
    • For automation, confirm plate height/format and deck compatibility.

    FAQs: Ordering, Storage, Method Notes & Validation

    1. Do these kits include methods or just reagents?
    They ship with concise method guidance and predefined protocols, so you can replicate conditions quickly without assembling parts from scratch.

    2. Can I automate sample prep with these kits?
    Yes—several kits and scripts are designed for automation-friendly formats (e.g., plate-based prep and workstation scripts) to increase throughput and consistency.

    3. Are refill or alternate-count packs available?
    For families like GlycoWorks, you can purchase starter, 96-sample, and refill configurations depending on study scale. Ask us for the SKU that matches your need.

    4. What storage/handling considerations apply?
    Follow kit-specific guidance included with each product to maintain reagent integrity and lot-to-lot consistency; check expiration and handling notes when your order arrives. (See product pages for details.)

    Related Collections: Vials, Standards & Reagents, Columns

    If you’re adapting a method or building out a full platform, you’ll likely add consumables from adjacent categories. Exploring these will help you sustain method performance over time and across instruments.

    Talk to iRight — Request a Quote

    Contact Iright to tell us your analyte, matrix, detector, and desired throughput, and we’ll match the best Waters Application Kit and pack size—plus any columns or accessories you need—to get you running quickly and reproducibly on your LC-MS platform.

    Order Guidelines

    1. Price & Stock Available on Request. Click to send email to: service@iright.com

    2. Please DO NOT make any payment before confirmation.

    3. Minimum order value of $1,000 USD required.

    4. 100% prepayment required.

    Collaboration

    Tony Tang

    Email: Tony.Tang@iright.com

    Mobile/WhatsApp/Wechat: +86-17717886924