Waters Application Kits: Faster, Reproducible LC-MS
150 productsWaters Application Kits give you an end-to-end, “ready-to-run” workflow for specific analytes and matrices. Each kit bundles validated consumables and method guidance so you can move from sample to result faster, with fewer variables and more reproducible outcomes across UPLC/LC-MS platforms.
What Are Waters Application Kits?
These kits combine sample-prep components, LC/UPLC columns, vials, standards/reagents, and concise method notes that have been verified to work together. You adopt a proven recipe instead of assembling parts yourself, reducing rework and shortening method development time from the first run.
At a glance (typical contents)
- Sample preparation module (e.g., SPE, digestion, labeling)
- LC/UPLC column(s) and compatible accessories
- Reagents/standards and simple protocols for setup and QC
Core LC-MS Applications & Use Cases
Start by matching your analytical goal to the kit family optimized for that chemistry. Kits span biomolecules and small molecules, covering routine quantification as well as advanced characterization, so you can standardize workflows across teams and instruments with minimal method drift.

-
Amino acids in biological samples (derivatization + UPLC separation) — AccQ•Tag Ultra/UPLC AAA.
-
N-glycan profiling with high sensitivity fluorescence/MS readout — GlycoWorks RapiFluor-MS.
-
Protein/peptide quantification via surrogate peptides in plasma/serum — ProteinWorks eXpress/Direct Digest.
-
Oligonucleotide bioanalysis from complex matrices — OligoWorks SPE workflows.
How Application Kits Accelerate LC-MS Workflows
You get consistency because critical steps—cleanup, derivatization, digestion, separation—are harmonized under one protocol. Reagents are pre-measured, methods are automation-friendly, and documentation guides validation, which together improves repeatability and shortens the path to reportable data.
Why it’s faster and more reproducible
- Pre-optimized chemistries reduce trial-and-error and batch variability.
- Lot-traceable reagents and defined protocols simplify transfer between sites.
- Automation scripts and plate-based formats speed high-throughput prep.
Product Families: GlycoWorks, AccQ-Tag Ultra, ProteinWorks, OligoWorks
Each family targets a distinct analyte class and preparation strategy. Use the summaries below to quickly narrow choices before you review specific SKUs and method notes.
-
GlycoWorks RapiFluor-MS — three-step N-glycan release, labeling, and cleanup with strong fluorescence and MS response; available in multiple sample counts.

-
AccQ•Tag Ultra/UPLC AAA — robust amino-acid derivatization kits underpinning Waters’ UPLC AAA application solution and UV detection workflows.

-
ProteinWorks eXpress/Direct Digest — pre-measured digestion reagents and protocols for whole or immunopurified plasma/serum, designed for LC-MS quantification via surrogate peptides.

- OligoWorks SPE — WAX-sorbent SPE plates/cartridges plus digestion module and eluents for high oligonucleotide recoveries and enhanced LC-MS performance.

Selection Guide: Choose by Analyte, Matrix & Platform (UPLC/LC-MS)
Use this quick matrix to jump to the right kit family. Filter by what you’re measuring, where it lives, and the prep you prefer; then confirm the matching SKU in the featured table.
Analyte class | Typical matrix | Prep highlight | Platform focus | Recommended family |
---|---|---|---|---|
Amino acids | Plasma, cell lysate, hydrolysates | AccQ•Tag derivatization | UPLC + UV/LC-MS | AccQ•Tag Ultra / UPLC AAA |
N-glycans | mAbs, glycoproteins | RapiFluor-MS label + cleanup | LC-FLR/LC-MS | GlycoWorks |
Tryptic peptides (surrogate) | Whole or immunopurified plasma/serum | Pre-measured digestion reagents | LC-MS/MS | ProteinWorks eXpress / Direct Digest |
Oligonucleotides | Plasma, serum, tissues | WAX SPE + pretreatment | LC-MS | OligoWorks SPE |
Featured Kits & SKUs (Validated Waters Catalogs)
Below are representative kits many labs start with. Each entry lists the family, catalog number, and primary use so you can request a quote confidently and map to your method files.
Kit / Family | Catalog No. | Target / Use | Included (summary) | Platform | Notes |
---|---|---|---|---|---|
GlycoWorks RapiFluor-MS N-Glycan Kit, 96-sample | 176003606 | Release, label, and analyze N-glycans with strong FLR/MS response | RapiFluor-MS reagents and cleanup materials for 96 samples | LC-FLR/LC-MS | Three easy steps; streamlined sample prep. |
GlycoWorks RapiFluor-MS N-Glycan Starter Kit, 24-sample | 176003712 | Starter format for method setup and small studies | Materials for 24 samples; refill available separately | LC-FLR/LC-MS | Good for pilots and training. |
AccQ•Tag Ultra Derivatization Kit | 186003836 | UPLC AAA workflows for amino acids | Derivatization reagents and method documentation | UPLC + UV/LC-MS | Component of UPLC AAA solution. |
AccQ•Tag Ultra Derivatization Kit – Automation | 186009232 | Automated AAA sample prep | Automation-oriented kit configuration | UPLC + UV/LC-MS | Streamlines high-throughput AAA. |
ProteinWorks eXpress Direct Digest Kit | 176003688 | Direct digestion of whole plasma/serum for LC-MS | Pre-measured reagents, optimized protocol | LC-MS/MS | Reduces prep time and variability. |
ProteinWorks eXpress Direct Digest Start-up Kit | 176003695 | Bundle for immediate adoption | Direct Digest kit + µElution SPE cleanup + mAb standard | LC-MS/MS | Convenient all-in-one start. |
OligoWorks SPE Microplate Kit | 186010614 | Oligonucleotide extraction/cleanup | 96-well WAX SPE plate, Proteinase K module, eluent, protocol | LC-MS | Automation-friendly design. |
OligoWorks SPE 3 cc Cartridge Kit | 186010616 | Cartridge-based SPE for oligos | 3 cc WAX cartridges (60 mg), digestion module, eluent, protocol | LC-MS | High recovery across matrices. |
Compatibility & Required Accessories for LC/UPLC & LC-MS
Before ordering, confirm the instrument class and small accessories that complete the workflow. Kits are designed to fit LC/UPLC and LC-MS methods, and many include vials or specify vial/cap formats to protect integrity from prep to injection.
Checklist
- Verify LC/UPLC system and detector (UV/FLR/MS) match the method.
- Ensure appropriate vials, caps, and column formats are on hand.
- For automation, confirm plate height/format and deck compatibility.
FAQs: Ordering, Storage, Method Notes & Validation
1. Do these kits include methods or just reagents?
They ship with concise method guidance and predefined protocols, so you can replicate conditions quickly without assembling parts from scratch.
2. Can I automate sample prep with these kits?
Yes—several kits and scripts are designed for automation-friendly formats (e.g., plate-based prep and workstation scripts) to increase throughput and consistency.
3. Are refill or alternate-count packs available?
For families like GlycoWorks, you can purchase starter, 96-sample, and refill configurations depending on study scale. Ask us for the SKU that matches your need.
4. What storage/handling considerations apply?
Follow kit-specific guidance included with each product to maintain reagent integrity and lot-to-lot consistency; check expiration and handling notes when your order arrives. (See product pages for details.)
Related Collections: Vials, Standards & Reagents, Columns
If you’re adapting a method or building out a full platform, you’ll likely add consumables from adjacent categories. Exploring these will help you sustain method performance over time and across instruments.
- Vials, Caps & Septa — support clean, consistent injections.
- Standards & Reagents — calibration blends and controls.
- Columns — application-matched UPLC/LC columns for separation stability.
Talk to iRight — Request a Quote
Contact Iright to tell us your analyte, matrix, detector, and desired throughput, and we’ll match the best Waters Application Kit and pack size—plus any columns or accessories you need—to get you running quickly and reproducibly on your LC-MS platform.
Order Guidelines
1. Price & Stock Available on Request. Click to send email to: service@iright.com
2. Please DO NOT make any payment before confirmation.
3. Minimum order value of $1,000 USD required.
4. 100% prepayment required.
Collaboration
Tony Tang
Email: Tony.Tang@iright.com
Mobile/WhatsApp/Wechat: +86-17717886924