Filter

    Waters Vials, Caps, Containers & Collection Plates

    255 products

    This collection brings together the small—but critical—consumables that keep your LC/LC-MS workflow clean, consistent, and efficient. From 12 × 32 mm autosampler vials and matching caps/septa to certified GL45 solvent containers and 96-well collection plates, each item is designed to reduce background, protect analytes, and integrate smoothly with Waters systems.

    What’s Included: Vials, Caps & Septa, Inserts, Containers, Collection Plates

    Every step from sample storage to autosampler injection and fraction collection has a purpose-built piece of hardware. Below is a practical overview so you can see what belongs where in a typical method—and why each choice matters for data quality and throughput.

    • Autosampler Vials (glass & PP) – 12 × 32 mm formats for 2 mL/1.5 mL fills, plus low-volume and max-recovery options. LC/GC- and LC/MS-certified lines help minimize extractables and carryover.
    Waters Autosampler Vials (glass & PP)
    • Caps & Septa – Color-coded, screw 9-425 closures with solid or preslit PTFE/silicone septa for clean resealing and reliable needle piercing. TruView™ and LCMS variants match vial lines.
    Waters Screw Cap Bonded Pre-Slit PTFE/Silicone Septa for 12 x 32 mm Vial Pack of 95 Caps
    • Vial Inserts – Glass or PP, with/without springs, to reduce dead volume and support micro-fills (e.g., 300 µL).

    • Certified Containers (GL45) – Ultra-clean Type I borosilicate bottles (e.g., 500 mL, 1 L) with low TOC specs for mobile phases and standards. Matching multi-port caps available.
    Waters Certified Containers
    • Collection Plates & Seals – 96-/384-well PP plates (350 µL to 2 mL) for fraction collection and high-throughput handling, with heat-seals and cap mats to suit solvents and storage.
    Waters Collection Plates & Seals

    How to Choose: Material, Volume, Closure & Autosampler Fit

    Choosing well is about matching chemistry and mechanics. First, pair material to solvent/analyte (glass vs PP, low-adsorption options). Then, size volume/insert to your fill level. Finally, confirm closure and dimensions match your autosampler/collector hardware.

    Quick selection matrix

    Scenario Recommended Material Volume/Format Closure/Septa Notes
    Routine LC quant Clear glass vial 1.5–2 mL (12 × 32 mm) 9-425 screw, PTFE/silicone (solid) Balanced cleanliness & resealability
    Light-sensitive analytes Amber glass vial 1.5–2 mL 9-425 screw, PTFE/silicone (solid) Added UV protection
    Trace-level LC/MS LC/MS-certified glass Max-recovery or Qsert 9-425 screw, preslit septum Low background; easier needle penetration
    High organic/adsorption-prone PP vial/insert 300–700 µL Screw cap, PTFE/silicone Avoids glass interaction for certain matrices
    Fraction collection PP plates 350 µL–2 mL wells Heat-seal or cap mat Choose well depth & seal by solvent/storage
    Mobile phase storage Type I glass container (GL45) 500 mL / 1 L Multi-port GL45 caps Low TOC; route inlet/waste safely


    Materials & Cleanliness for LC/LC-MS: Glass vs PP, Low-Adsorption Options

    Material impacts both analyte recovery and background noise. Type I borosilicate glass is the default for most methods; amber variants add UV protection. Polypropylene helps when glass interaction is a risk or when aggressive rinsing cycles are used. Certified lines (LC/GC, LC/MS, TruView™) are tested for cleanliness to reduce ghost peaks and ion suppression.

    At-a-glance considerations

    • Glass (clear/amber): Dimensional stability; broad solvent compatibility; ideal with solid or preslit PTFE/silicone septa.
    • PP (vials/inserts/plates): Good for adsorption-sensitive analytes and plate workflows; confirm seal type for organic content and storage temperature. 
      waters.com
    • Certified Containers (GL45): Low TOC reservoirs help prevent background in high-sensitivity LC/LC-MS.

    Fit & Compatibility with Waters Autosamplers & Fraction Collectors

    Mechanical fit ensures repeatable injections and clean fractions. Confirm vial geometry (e.g., 12 × 32 mm), neck finish (9-425 screw, 11 mm crimp/snap), and insert height. For plates, use the pre-programmed ANSI 96/384 geometries and choose well depth to minimize residual volume at your needle offset. Containers should use GL45 threads with appropriate caps/tubing.

    Compatibility notes

    • Vials: certified kits are available with matched caps/septa, including max-recovery and Qsert options for low residues.
    • Plates: 96-well 350 µL, 700 µL, 1 mL and 2 mL square-well formats are supported; seals include polyester/aluminum heat-seals and adhesive films.
    • Containers: 500 mL/1 L certified bottles pair with multi-port GL45 caps for safe inlet/waste routing.

    Featured Models & Specs: Waters Certified Vials, Caps/Septa, Inserts & Plates

    To help you start fast, here’s a representative cross-section that covers the most common tasks. Each SKU links to a compatible category family so you can expand as your method evolves.

    Catalog # Type Material Volume/Format Closure/Septa Cleanliness Notes
    186004902C Screw-neck vial (kit) Clear glass 15 × 75 mm With cap, PTFE/silicone LC/GC-certified General LC/GC workflows
    186004903C Screw-neck vial (kit) Clear glass 15 × 75 mm With cap, preslit PTFE/silicone LC/GC-certified Easier needle entry
    186001131C Qsert vial (kit) Amber glass 12 × 32 mm / 300 µL With cap, preslit LC/GC-certified Low volume + light protection
    600000749CV Max-recovery vial (kit) Clear glass 12 × 32 mm / 1.5 mL With cap, PTFE/silicone LC/MS-certified Low background for LC/MS
    186002626 Screw-neck vial PP 12 × 32 mm / 300 µL Adsorption-sensitive matrices
    WAT094170 Low-volume insert Glass + spring 6 × 29 mm / 300 µL Micro-fills, stable pickup
    186005829 Cap & preslit septum PTFE/silicone 12 × 32 mm 9-425 screw For LC/MS-certified vials Light-blue code
    186002643 96-well plate PP, round 350 µL/well Heat-seal/cap mat options Low residual volume
    186005837 96-well plate PP, round 700 µL/well Heat-seal/cap mat options Deeper wells for prep
    186002482 96-well plate PP, square 2 mL/well Heat-seal/cap mat options High-volume fractions
    186007090 Certified container Type I glass (GL45) 500 mL GL45 cap Low TOC Mobile-phase grade
    186007089 Certified container Type I glass (GL45) 1 L GL45 cap Low TOC Mobile-phase grade 

    Applications & Workflows: Sampling, Storage & Fraction Collection

    Each item earns its keep when placed in a real method. Think of vials as the gateway to repeatable injections, plates as the backbone of prep/fraction work, and certified containers as the silent partner protecting your baselines in sensitive LC/LC-MS assays.

    • Batch quant & method development: Pair certified glass vials with preslit caps to ensure consistent needle penetration and resealing across large runs. Low-volume/Qsert options minimize headspace for small-sample work.
    • Semi-prep & purification: Route defined time or MS-triggered fractions into 96-well plates sized for your downstream evaporation and reconstitution steps; select seals by solvent and storage horizon.
    • Mobile-phase & standards: Use low-TOC GL45 containers to reduce ghost peaks and keep tubing organized with multi-port caps.

    FAQs: HPLC/LC-MS Vials, Caps & Septa, Inserts, and Collection Plates

    Q1: When should I choose preslit vs solid septa?
    Preslit PTFE/silicone lowers piercing force and improves resealability for repeated injections; solid septa resist vapor loss a bit better for storage. Match the cap to the vial line (LC/GC, TruView™, LC/MS) for predictable performance.

    Q2: Do 12 × 32 mm vials always hold 2 mL?
    They’re commonly used at ~1.5–2.0 mL, but “max-recovery” geometries are specified by manufacturer; check the stated capacity (e.g., 1.5 mL) and choose inserts for micro-fills.

    Q3: Which plate format minimizes residual volume?
    Waters’ 96-well 350 µL and 700 µL plates are designed with well depths that pair to autosampler needle offsets; use the recommended ANSI geometries and seals to keep residuals low.

    Q4: Why certified solvent containers instead of generic bottles?
    Low-TOC certified containers reduce background and spurious peaks in high-sensitivity LC/LC-MS—especially important when methods push detection limits.

    Related Waters Collections: Columns, Sample Prep, Standards & Reagents

    These pages round out the same workflow: method building on columns, clean-up with SPE/filtration, and reference materials for qualification. Linking them keeps procurement and validation straightforward across teams and instruments.

    Talk to Iright: Request a Quote & Compatibility Check

    Choosing the right combination is faster when you have a partner who lives in both chromatography and procurement. Tell us your solvent system, target volume, closure preference, and autosampler/collector model—we’ll return a compatible short-list, lead times, and bundle pricing, backed by Iright’s track record serving regulated and research labs.

    Order Guidelines

    1. Price & Stock Available on Request. Click to send email to: service@iright.com

    2. Please DO NOT make any payment before confirmation.

    3. Minimum order value of $1,000 USD required.

    4. 100% prepayment required.

    Collaboration

    Tony Tang

    Email: Tony.Tang@iright.com

    Mobile/WhatsApp/Wechat: +86-17717886924